10 research outputs found

    Ring Expansion of Cyclobutylmethylcarbenium Ions to Cyclopentane or Cyclopentene Derivatives and Metal-Promoted Analogous Rearrangements

    Full text link

    Feedback to the field: an assessment of sternal intraosseous (IO) infusion.

    No full text
    Intraosseous vascular infusion (IO) is a recognized alternative to peripheral intravenous infusion when access is inadequate. The sternum and proximal tibia are the preferred sites. A review of 98 cases at autopsy revealed successful sternal IO placement in 78 cases (80%). Assuming a worst case scenario for placement (pin mark and no tip in bone [17 cases] and tip present and not in the sternum [3 cases]), attempts were unsuccessful in 20 cases (20%). We draw no specific conclusions regarding sternal IO use, but hope that personnel placing these devices and those providing medical training can use the information

    Analysis of recovered tourniquets from casualties of Operation Enduring Freedom and Operation New Dawn.

    No full text
    BACKGROUND: Tourniquet use recently became common in war, but knowledge gaps remain regarding analysis of recovered devices. The purpose of this study was to analyze tourniquets to identify opportunities for improved training. METHODS: We analyzed tourniquets recovered from deceased service members serving in support of recent combat operations by a team at Dover Air Force Base from 2010 to 2012. Device makes and models, breakage, deformation, band routing, and windlass turn numbers were counted. RESULTS: We recovered 824 tourniquets; 390 were used in care and 434 were carried unused. Most tourniquets were recommended by the Committee on Tactical Combat Casualty Care (Combat Application Tourniquet [CAT] or Special Operations Forces Tactical Tourniquet). The band was routed once through the buckle in 37% of used CATs, twice in 62%, and 1% had none. For tourniquets with data, the windlass turn number averaged 3.2 (range, 0-9). The CAT windlass turn number was associated positively with tourniquet deformation as moderate or severe deformation began at 2 turns, increased in likelihood stepwise with each turn, and became omnipresent at 7 or more. CONCLUSIONS: Tourniquet counts, band routings, windlass turn numbers, and deformation rates are candidate topics for instructors to refine training

    Dimensionen der nationalen Frage

    No full text

    Energy levels of Z = 11−21 nuclei (IV)

    No full text
    Compilation of experimentally determined properties of energy levels of Z = 11−21 nuclei with special emphasis on nuclear spectroscopy

    Energy levels of Z = 11−21 nuclei (IV)

    No full text

    Energy levels of A = 21–44 nuclei (VI)

    No full text
    corecore