11 research outputs found
Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer
BACKGROUND: Reproducible measurements of the range of motion are an important prerequisite for the interpretation of study results. The digital inclinometer is considered to be a useful instrument because it is inexpensive and easy to use. No previous study assessed inter-observer reproducibility of range of motion measurements with a digital inclinometer by physical therapists in a large sample of patients. METHODS: Two physical therapists independently measured the passive range of motion of the glenohumeral abduction and the external rotation in 155 patients with shoulder pain. Agreement was quantified by calculation of the mean differences between the observers and the standard deviation (SD) of this difference and the limits of agreement, defined as the mean difference ± 1.96*SD of this difference. Reliability was quantified by means of the intraclass correlation coefficient (ICC). RESULTS: The limits of agreement were 0.8 ± 19.6 for glenohumeral abduction and -4.6 ± 18.8 for external rotation (affected side) and quite similar for the contralateral side and the differences between sides. The percentage agreement within 10° for these measurements were 72% and 70% respectively. The ICC ranged from 0.28 to 0.90 (0.83 and 0.90 for the affected side). CONCLUSIONS: The inter-observer agreement was found to be poor. If individual patients are assessed by two different observers, differences in range of motion of less than 20–25 degrees can not be distuinguished from measurement error. In contrast, acceptable reliability was found for the inclinometric measurements of the affected side and the differences between the sides, indicating that the inclimeter can be used in studies in which groups are compared
Decision making factors of the management of ductal carcinoma in situ of the breast with microinvasion
International audienceIntroductionMicroinvasive in situ ductal carcinomas of the breast are rare and of good prognosis. They are grouped with early stage invasive carcinomas in the TNM 2017 classification. This study assessed practitioners’ treatment decisions and their justifications in comparison to the literature.Materials and methodsThree clinical cases were evaluated by anonymous forms regarding sentinel node decisions, tumour bed boost irradiation and hormone therapy.ResultsSentinel lymph node was performed by 93.1%, 100% and 44.4% of the practitioners respectively. Radiation boost was a treatment option chosen by 62.1% and 61.1% of practitioners in both clinical cases. Hormone therapy was advocated for 65.5%, 94.7% and 50.0% patients depending on the clinical case.ConclusionThe therapeutic attitude proposed in microinvasive breast carcinomas was heterogeneous in this study, reflecting the absence of specific recommendations. In view of the existing literature, it is not currently possible to propose recommendations for these three therapeutic options. Prospective cohorts and meta-analyses of the microinvasive subgroup could provide answers
Prospective Assessment of Early Proton Therapy-Induced Optic Neuropathy in Patients With Intracranial, Orbital or Sinonasal Tumors: Impact of A Standardized Ophthalmological Follow Up
CERVOXY CLINInternational audiencePurpose Proton therapy (PT) can be a good option to achieve tumor control while reducing the probability of radiation induced toxicities compared to X-ray-based radiotherapy. However, there are still uncertainties about the effects of PT on the organs in direct contact with the irradiated volume. The aim of this prospective series was to report 6-month follow-up of clinical and functional optic neuropathy rates of patients treated by proton therapy using a standardized comprehensive optic examination. Methods and Materials Standardized ophthalmological examinations were performed to analyze subclinical anomalies in a systematic way before treatment and 6 months after the end of proton therapy with: Automatic visual field, Visual evoked potential (VEP) and optic coherence of tomography (OCT). Results From October 2018 to July 2020 we analyzed 81 eyes. No significant differences were found in the analysis of the clinical examination of visual functions by the radiation oncologist. However, considering VEP, the impairment was statistically significant for both fibers explored at 30’angle (p:0.007) and 60’angle (p <0.001). In patients with toxicity, the distance of the target volume from the optical pathways was more important with a p-value for 30’VEP at 0.035 and for 60’VEP at 0.039. Conclusions These results confirm uncertainties concerning relative biological effectiveness of proton therapy, linear energy transfer appears to be more inhomogeneous especially in areas close to the target volumes. The follow-up of patients after proton therapy is not an easy process to set up but it is necessary to improve our knowledges about the biological effects of proton therapy in real life. Our study which will continue during the coming years, suggests that follow-up with in-depth examinations such as VEP as a biomarker could improve the detection of early abnormalities
Interobserver reproducibility of the visual estimation of range of motion of the shoulder
Abstract Terwee CB, de Winter AF, Scholten RJ, Jans MP, Deville W, van Schaardenburg D, Bouter LM. Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Objectives To assess interobserver reproducibility (agreement and reliability) of visually estimated shoulder range of motion (ROM) and to study the influence of clinical characteristics on the reproducibility. Design Test-retest analyses. Setting Various health care settings in the Netherlands. Participants Consecutive patients with shoulder complaints (N=201) referred by 20 general practitioners, 2 orthopedic physicians, and 20 rheumatologists. Interventions Not applicable. Main Outcome Measures Independent visual estimation by 2 physiotherapists of the ROM. Agreement was calculated as the mean difference in visual estimation between examiners +/-1.96 x standard deviations of this mean difference. The intraclass correlation coefficient (ICC) was calculated as a measure of reliability, based on a 2-way random effects analysis of variance. Results The lowest level of agreement was for visual estimation of active and passive elevation (limits of agreement, -43.4 to 39.8 and -46.7 to 41.5, respectively, for the difference between the affected and contralateral sides), for which the level of agreement was most clearly associated with pain severity and disability. The ability to differentiate between subjects was acceptable for all movements for the difference between the affected and contralateral sides (ICCs, >.70) except for horizontal adduction (ICC=.49). Conclusions Interobserver agreement was low for the assessment of active and passive elevation, especially for patients with a high pain severity and disability. Except for horizontal adduction, visual estimation seems suitable for distinguishing differences between affected and contralateral ROM between subject