105 research outputs found

    Influence of cementless hip stems on femoral cortical strain pattern depending on their extent of porous coating

    Get PDF
    The extent of porous coating of cementless total hip stems is held responsible for radiological periprosthetic changes, the rate of thigh pain, and even its long-term success. However, there is only sparse knowledge on how the biomechanical loading conditions of the femur are influenced by the extent of porous coating in the early phase after implantation of a cementless hip stem. Aiming to evaluate the effect of surface structuring on the strain pattern of the femur, we implanted three anatomic hip stems with different extents of porous coating (full, two-thirds proximal, and penguin type) in second-generation composite femora coated with a photoelastic layer. A cortical strain mapping was conducted before and after insertion of the implants under standardized loading conditions considering relevant muscle forces. The results of the statistical analysis of three different implantation sequences proved that composite femora are suitable for repeated measurements within the applied experimental setup. Cortical strain changes including stress-shielding effects medially (-60%) and laterally (-50%) were validated with a cadaver femur. The extent of porous coating had no significant influence on the surface strain pattern for an immediate postoperative situation

    Einfluss der Defektgröße des femoralen Knochenlagers auf die Primärstabilität modularer Revisionshüftstiele: eine biomechanische Analyse

    Get PDF
    Ziel der vorliegenden experimentellen Arbeit ist die Schaffung von Grundlagen für eine optimale Versorgungsstrategie bei femoralen Knochendefekten im Rahmen der Revisionsendoprothetik des Hüftgelenkes. Anhand eines dynamischen In-vitro-Prüfmodelles mit Composite-Femora wurde die Primärstabilität modularer zementfreier konischer Hüftrevisionsstiele mit Längsrippen in Abhängigkeit von der Defektgröße des femoralen Lagers ermittelt. Die Resultate wurden durch Untersuchungen am Humanfemur sowie mittels eines ebenfalls im Rahmen dieses Projektes entwickelten Finite-Elemente-Modelles validiert

    Two-stage revision of implant-associated infections after total hip and knee arthroplasty

    Get PDF
    Septic loosening of total hip and knee endoprostheses gains an increasing proportion of revision arthroplasties. Operative revisions of infected endoprostheses are mentally and physically wearing for the patient, challenging for the surgeon and a significant economic burden for healthcare systems. In cases of early infection within the first three weeks after implantation a one-stage revision with leaving the implant in place is widely accepted. The recommendations for the management of late infections vary by far. One-stage revisions as well as two-stage or multiple revision schedules have been reported to be successful in over 90% of all cases for certain patient collectives. But implant associated infection still remains a severe complication. Moreover, the management of late endoprosthetic infection requires specific logistics, sufficient and standardized treatment protocol, qualified manpower as well as an efficient quality management. With regard to the literature and experience of specialized orthopaedic surgeons from several university and regional hospitals we modified a commonly used treatment protocol for two-stage revision of infected total hip and knee endoprostheses. In addition to the achievement of maximum survival rate of the revision implants an optimisation of the functional outcome of the affected artificial joint is aimed for

    Nuclear Factor of Activated T Cells-dependent Down-regulation of the Transcription Factor Glioma-associated Protein 1 (GLI1) Underlies the Growth Inhibitory Properties of Arachidonic Acid

    Get PDF
    Numerous reports have demonstrated a tumor inhibitory effect of polyunsaturated fatty acids (PUFAs). However, the molecular mechanisms modulating this phenomenon are in part poorly understood. Here, we provide evidence of a novel antitumoral mechanism of the PUFA arachidonic acid (AA). In vivo and in vitro experiments showed that AA treatment decreased tumor growth and metastasis, and increased apoptosis. Molecular analysis of this effect showed significantly reduced expression of a subset of antiapoptotic proteins, including BCL2, BFL1/A1 and 4-1BB, in AA-treated cells. We demonstrated that downregulation of the transcription factor GLI1 in AA-treated cells is the underlying mechanism controlling BCL2, BFL1/A1 and 4-1BB expression. Using luciferase reporters, chromatin immunoprecipitation, and expression studies, we found that GLI1 binds to the promoter of these antiapoptotic molecules, and regulates their expression and promoter activity. We provide evidence that AA-induced apoptosis and downregulation of antiapoptotic genes can be inhibited by overexpressing GLI1 in AA-sensitive cells. Conversely, inhibition of GLI1 mimics AA treatments, leading to decreased tumor growth, cell viability and expression of antiapoptotic molecules. Further characterization showed that AA represses GLI1 expression by stimulating NFATc1 nuclear translocation, which then binds the GLI1 promoter and represses its transcription. AA was shown to increase reactive oxygen species. Treatment with antioxidants reduced the AA-induced apoptosis, downregulation of GLI1 and NFATc1 activation, indicating that NFATc1 activation and GLI1 repression require the generation of reactive oxygen species. Collectively, these results define a novel mechanism underlying AA antitumoral functions that may serve as a foundation for the future PUFA-based therapeutic approaches

    LTCC and thick-film ceramic magnetic sensors for tokamak nuclear fusion

    Get PDF
    The present contribution gives an overview of our work on non-conventional magnetic coil sensors for diagnostics and plasma stability control of nuclear fusion experiments in tokamaks. Instead of wire wound around a core, these devices consist of printed conductor wire coils on ceramic substrates, and are based on LTCC (low-temperature co-fired ceramic) and thick-film technology, which allow creation of monolithic multilayer coils with excellent stability. For 3D sensing, an innovative modular design combining LTCC coils and an alumina base has been developed. Finally, the important aspects of integration, manufacturing, mounting and interconnection are discussed

    Open Surgical versus Minimal Invasive Necrosectomy of the Pancreas-A Retrospective Multicenter Analysis of the German Pancreatitis Study Group

    Get PDF
    Background Necrotising pancreatitis, and particularly infected necrosis, are still associated with high morbidity and mortality. Since 2011, a step-up approach with lower morbidity rates compared to initial open necrosectomy has been established. However, mortality and complication rates of this complex treatment are hardly studied thereafter. Methods The German Pancreatitis Study Group performed a multicenter, retrospective study including 220 patients with necrotising pancreatitis requiring intervention, treated at 10 hospitals in Germany between January 2008 and June 2014. Data were analysed for the primary endpoints "severe complications" and "mortality" as well as secondary endpoints including "length of hospital stay", "follow up", and predisposing or prognostic factors. Results Of all patients 13.6% were treated primarily with surgery and 86.4% underwent a step-up approach. More men (71.8%) required intervention for necrotising pancreatitis. The most frequent etiology was biliary (41.4%) followed by alcohol (29.1%). Compared to open necrosectomy, the step-up approach was associated with a lower number of severe complications (primary composite endpoint including sepsis, persistent multiorgan dysfunction syndrome (MODS) and erosion bleeding: 44.7% vs. 73.3%), lower mortality (10.5% vs. 33.3%) and lower rates of diabetes mellitus type 3c (4.7% vs. 33.3%). Low hematocrit and low blood urea nitrogen at admission as well as a history of acute pancreatitis were prognostic for less complications in necrotising pancreatitis. A combination of drainage with endoscopic necrosectomy resulted in the lowest rate of severe complications. Conclusion A step-up approach starting with minimal invasive drainage techniques and endoscopic necrosectomy results in a significant reduction of morbidity and mortality in necrotising pancreatitis compared to a primarily surgical intervention

    Transcriptome Analysis of the Model Protozoan, Tetrahymena thermophila, Using Deep RNA Sequencing

    Get PDF
    Background: The ciliated protozoan Tetrahymena thermophila is a well-studied single-celled eukaryote model organism for cellular and molecular biology. However, the lack of extensive T. thermophila cDNA libraries or a large expressed sequence tag (EST) database limited the quality of the original genome annotation. Methodology/Principal Findings: This RNA-seq study describes the first deep sequencing analysis of the T. thermophila transcriptome during the three major stages of the life cycle: growth, starvation and conjugation. Uniquely mapped reads covered more than 96 % of the 24,725 predicted gene models in the somatic genome. More than 1,000 new transcribed regions were identified. The great dynamic range of RNA-seq allowed detection of a nearly six order-of-magnitude range of measurable gene expression orchestrated by this cell. RNA-seq also allowed the first prediction of transcript untranslated regions (UTRs) and an updated (larger) size estimate of the T. thermophila transcriptome: 57 Mb, or about 55 % of the somatic genome. Our study identified nearly 1,500 alternative splicing (AS) events distributed over 5.2 % of T. thermophila genes. This percentage represents a two order-of-magnitude increase over previous EST-based estimates in Tetrahymena. Evidence of stage-specific regulation of alternative splicing was also obtained. Finally, our study allowed us to completely confirm about 26.8 % of the genes originally predicted by the gene finder, to correct coding sequence boundaries an

    Human matrix metalloproteinases: An ubiquitarian class of enzymes involved in several pathological processes

    Get PDF
    Human matrix metalloproteinases (MMPs) belong to the M10 family of the MA clan of endopeptidases. They are ubiquitarian enzymes, structurally characterized by an active site where a Zn(2+) atom, coordinated by three histidines, plays the catalytic role, assisted by a glutamic acid as a general base. Various MMPs display different domain composition, which is very important for macromolecular substrates recognition. Substrate specificity is very different among MMPs, being often associated to their cellular compartmentalization and/or cellular type where they are expressed. An extensive review of the different MMPs structural and functional features is integrated with their pathological role in several types of diseases, spanning from cancer to cardiovascular diseases and to neurodegeneration. It emerges a very complex and crucial role played by these enzymes in many physiological and pathological processes

    Non-invasive diagnostic tests for Helicobacter pylori infection

    Get PDF
    BACKGROUND: Helicobacter pylori (H pylori) infection has been implicated in a number of malignancies and non-malignant conditions including peptic ulcers, non-ulcer dyspepsia, recurrent peptic ulcer bleeding, unexplained iron deficiency anaemia, idiopathic thrombocytopaenia purpura, and colorectal adenomas. The confirmatory diagnosis of H pylori is by endoscopic biopsy, followed by histopathological examination using haemotoxylin and eosin (H & E) stain or special stains such as Giemsa stain and Warthin-Starry stain. Special stains are more accurate than H & E stain. There is significant uncertainty about the diagnostic accuracy of non-invasive tests for diagnosis of H pylori. OBJECTIVES: To compare the diagnostic accuracy of urea breath test, serology, and stool antigen test, used alone or in combination, for diagnosis of H pylori infection in symptomatic and asymptomatic people, so that eradication therapy for H pylori can be started. SEARCH METHODS: We searched MEDLINE, Embase, the Science Citation Index and the National Institute for Health Research Health Technology Assessment Database on 4 March 2016. We screened references in the included studies to identify additional studies. We also conducted citation searches of relevant studies, most recently on 4 December 2016. We did not restrict studies by language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA: We included diagnostic accuracy studies that evaluated at least one of the index tests (urea breath test using isotopes such as13C or14C, serology and stool antigen test) against the reference standard (histopathological examination using H & E stain, special stains or immunohistochemical stain) in people suspected of having H pylori infection. DATA COLLECTION AND ANALYSIS: Two review authors independently screened the references to identify relevant studies and independently extracted data. We assessed the methodological quality of studies using the QUADAS-2 tool. We performed meta-analysis by using the hierarchical summary receiver operating characteristic (HSROC) model to estimate and compare SROC curves. Where appropriate, we used bivariate or univariate logistic regression models to estimate summary sensitivities and specificities. MAIN RESULTS: We included 101 studies involving 11,003 participants, of which 5839 participants (53.1%) had H pylori infection. The prevalence of H pylori infection in the studies ranged from 15.2% to 94.7%, with a median prevalence of 53.7% (interquartile range 42.0% to 66.5%). Most of the studies (57%) included participants with dyspepsia and 53 studies excluded participants who recently had proton pump inhibitors or antibiotics.There was at least an unclear risk of bias or unclear applicability concern for each study.Of the 101 studies, 15 compared the accuracy of two index tests and two studies compared the accuracy of three index tests. Thirty-four studies (4242 participants) evaluated serology; 29 studies (2988 participants) evaluated stool antigen test; 34 studies (3139 participants) evaluated urea breath test-13C; 21 studies (1810 participants) evaluated urea breath test-14C; and two studies (127 participants) evaluated urea breath test but did not report the isotope used. The thresholds used to define test positivity and the staining techniques used for histopathological examination (reference standard) varied between studies. Due to sparse data for each threshold reported, it was not possible to identify the best threshold for each test.Using data from 99 studies in an indirect test comparison, there was statistical evidence of a difference in diagnostic accuracy between urea breath test-13C, urea breath test-14C, serology and stool antigen test (P = 0.024). The diagnostic odds ratios for urea breath test-13C, urea breath test-14C, serology, and stool antigen test were 153 (95% confidence interval (CI) 73.7 to 316), 105 (95% CI 74.0 to 150), 47.4 (95% CI 25.5 to 88.1) and 45.1 (95% CI 24.2 to 84.1). The sensitivity (95% CI) estimated at a fixed specificity of 0.90 (median from studies across the four tests), was 0.94 (95% CI 0.89 to 0.97) for urea breath test-13C, 0.92 (95% CI 0.89 to 0.94) for urea breath test-14C, 0.84 (95% CI 0.74 to 0.91) for serology, and 0.83 (95% CI 0.73 to 0.90) for stool antigen test. This implies that on average, given a specificity of 0.90 and prevalence of 53.7% (median specificity and prevalence in the studies), out of 1000 people tested for H pylori infection, there will be 46 false positives (people without H pylori infection who will be diagnosed as having H pylori infection). In this hypothetical cohort, urea breath test-13C, urea breath test-14C, serology, and stool antigen test will give 30 (95% CI 15 to 58), 42 (95% CI 30 to 58), 86 (95% CI 50 to 140), and 89 (95% CI 52 to 146) false negatives respectively (people with H pylori infection for whom the diagnosis of H pylori will be missed).Direct comparisons were based on few head-to-head studies. The ratios of diagnostic odds ratios (DORs) were 0.68 (95% CI 0.12 to 3.70; P = 0.56) for urea breath test-13C versus serology (seven studies), and 0.88 (95% CI 0.14 to 5.56; P = 0.84) for urea breath test-13C versus stool antigen test (seven studies). The 95% CIs of these estimates overlap with those of the ratios of DORs from the indirect comparison. Data were limited or unavailable for meta-analysis of other direct comparisons. AUTHORS' CONCLUSIONS: In people without a history of gastrectomy and those who have not recently had antibiotics or proton ,pump inhibitors, urea breath tests had high diagnostic accuracy while serology and stool antigen tests were less accurate for diagnosis of Helicobacter pylori infection.This is based on an indirect test comparison (with potential for bias due to confounding), as evidence from direct comparisons was limited or unavailable. The thresholds used for these tests were highly variable and we were unable to identify specific thresholds that might be useful in clinical practice.We need further comparative studies of high methodological quality to obtain more reliable evidence of relative accuracy between the tests. Such studies should be conducted prospectively in a representative spectrum of participants and clearly reported to ensure low risk of bias. Most importantly, studies should prespecify and clearly report thresholds used, and should avoid inappropriate exclusions

    Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    No full text
    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup.After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41–58° (threaded cups) to 39–77° (press-fit cups).The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred
    corecore