240 research outputs found

    First Earth-based Detection of a Superbolide on Jupiter

    Get PDF
    Cosmic collisions on planets cause detectable optical flashes that range from terrestrial shooting stars to bright fireballs. On June 3, 2010 a bolide in Jupiter's atmosphere was simultaneously observed from the Earth by two amateur astronomers observing Jupiter in red and blue wavelengths. The bolide appeared as a flash of 2 s duration in video recording data of the planet. The analysis of the light curve of the observations results in an estimated energy of the impact of 0.9-4.0x10^{15} J which corresponds to a colliding body of 8-13 m diameter assuming a mean density of 2 g cm^{-3}. Images acquired a few days later by the Hubble Space Telescope and other large ground-based facilities did not show any signature of aerosol debris, temperature or chemical composition anomaly, confirming that the body was small and destroyed in Jupiter's upper atmosphere. Several collisions of this size may happen on Jupiter on a yearly basis. A systematic study of the impact rate and size of these bolides can enable an empirical determination of the flux of meteoroids in Jupiter with implications for the populations of small bodies in the outer Solar System and may allow a better quantification of the threat of impacting bodies to Earth. The serendipitous recording of this optical flash opens a new window in the observation of Jupiter with small telescopes

    Impact flux on Jupiter: From superbolides to large-scale collisions

    Get PDF
    Context. Regular observations of Jupiter by a large number of amateur astronomers have resulted in the serendipitous discovery of short bright flashes in its atmosphere, which have been proposed as being caused by impacts of small objects. Three flashes were detected: one on June 3, 2010, one on August 20, 2010, and one on September 10, 2012. Aims. We show that the flashes are caused by impacting objects that we characterize in terms of their size, and we study the flux of small impacts on Jupiter. Methods. We measured the light curves of these atmospheric airbursts to extract their luminous energy and computed the masses and sizes of the objects. We ran simulations of impacts and compared them with the light curves. We analyzed the statistical significance of these events in the large pool of Jupiter observations. Results. All three objects are in the 5-20 m size category depending on their density, and they released energy comparable to the recent Chelyabinsk airburst. Model simulations approximately agree with the interpretation of the limited observations. Biases in observations of Jupiter suggest a rate of 12-60 similar impacts per year and we provide software tools for amateurs to examine the faint signature of impacts in their data to increase the number of detected collisions. Conclusions. The impact rate agrees with dynamical models of comets. More massive objects (a few 100 m) should impact with Jupiter every few years leaving atmospheric dark debris features that could be detectable about once per decade

    Effectiveness of systematic screening for the detection of atrial fibrillation

    Full text link
    © 2013 The Cochrane Collaboration. Background: Atrial fibrillation (AF) is the most common arrhythmia in clinical practice and is a leading cause of morbidity and mortality. Screening for AF in asymptomatic patients has been proposed as a way of reducing the burden of the disease by detecting people who would benefit from prophylactic anticoagulation therapy prior to the onset of symptoms. However, for screening to be an effective intervention it must improve the detection of AF and provide benefit for those who are detected earlier as a result of screening. Objectives: The primary objective of this review was to examine whether screening programmes increase the detection of new cases of AF compared to routine practice. The secondary objectives were to identify which combination of screening strategy and patient population is most effective, as well as assessing any safety issues associated with screening, its acceptability within the target population and the costs involved. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library, MEDLINE (Ovid) and EMBASE (Ovid) up to March 2012. Other relevant research databases, trials registries and websites were searched up to June 2012. Reference lists of identified studies were also searched for potentially relevant studies and we contacted corresponding authors for information about additional published or unpublished studies that may be relevant. No language restrictions were applied. Selection criteria: Randomised controlled trials, controlled before and after studies and interrupted time series studies comparing screening for AF with routine practice in people aged 40 years and over were eligible. Two authors (PM, CT or MF) independently selected the trials for inclusion. Data collection and analysis: Assessment of risk of bias and data extraction were performed independently by two authors (PM, CT). Odds ratios (OR) and 95% confidence intervals (CI) were used to present the results for the primary outcome, which is a dichotomous variable. Since only one included study was identified, no meta-analysis was performed. Main results: One cluster randomised controlled trial met the inclusion criteria for this review. This study compared systematic screening (by invitation to have an electrocardiogram (ECG)) and opportunistic screening (pulse palpation during a general practitioner (GP) consultation for any reason followed by an ECG if pulse was irregular) to routine practice (normal case finding on the basis of clinical presentation) in people aged 65 years or older. The risk of bias in the included study was judged to be low. Both systematic and opportunistic screening of people over the age of 65 years are more effective than routine practice (OR 1.57, 95% CI 1.08 to 2.26 and OR 1.58, 95% CI 1.10 to 2.29, respectively). The number needed to screen in order to detect one additional case compared to routine practice was 172 (95% CI 94 to 927) for systematic screening and 167 (95% CI 92 to 806) for opportunistic screening. Both systematic and opportunistic screening were more effective in men (OR 2.68, 95% CI 1.51 to 4.76 and OR 2.33, 95% CI 1.29 to 4.19, respectively) than in women (OR 0.98, 95% CI 0.59 to 1.62 and OR 1.2, 95% CI 0.74 to 1.93, respectively). No data on the effectiveness of screening in different ethnic or socioeconomic groups were available. There were insufficient data to compare the effectiveness of screening programmes in different healthcare settings. Systematic screening was associated with a better overall uptake rate than opportunistic screening (53% versus 46%) except in the ≥ 75 years age group where uptake rates were similar (43% versus 42%). In both screening programmes men were more likely to participate than women (57% versus 50% in systematic screening, 49% versus 41% in opportunistic screening) and younger people (65 to 74 years) were more likely to participate than people aged 75 years and over (61% versus 43% systematic, 49% versus 42% opportunistic). No adverse events associated with screening were reported. The incremental cost per additional case detected by opportunistic screening was GBP 337, compared to GBP 1514 for systematic screening. All cost estimates were based on data from the single included trial, which was conducted in the UK between 2001 and 2003. Authors' conclusions: Systematic and opportunistic screening for AF increase the rate of detection of new cases compared with routine practice. While both approaches have a comparable effect on the overall AF diagnosis rate, the cost of systematic screening is significantly more than that of opportunistic screening from the perspective of the health service provider. The lack of studies investigating the effect of screening in other health systems and younger age groups means that caution needs to be exercised in relation to the transferability of these results beyond the setting and population in which the included study was conducted. Additional research is needed to examine the effectiveness of alternative screening strategies and to investigate the effect of the intervention on the risk of stroke for screened versus non-screened populations

    Colour terms affect detection of colour and colour-associated objects suppressed from visual awareness

    Get PDF
    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d’) and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object’s stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain

    New Frontiers-class Uranus Orbiter: Exploring the feasibility of achieving multidisciplinary science with a mid-scale mission

    Get PDF
    n/

    Advantages of a cohort study on cardiac arrest conducted by nurses

    Get PDF
    AbstractOBJECTIVEIdentifying factors associated to survival after cardiac arrest.METHODAn experience report of a cohort study conducted in a university hospital, with a consecutive sample comprised of 285 patients. Data were collected for a year by trained nurses. The training strategy was conducted through an expository dialogue lecture. Collection monitoring was carried out by nurses via telephone calls, visits to the emergency room and by medical record searches. The neurological status of survivors was evaluated at discharge, after six months and one year.RESULTSOf the 285 patients, 16 survived until hospital discharge, and 13 remained alive after one year, making possible to identify factors associated with survival. There were no losses in the process.CONCLUSIONCohort studies help identify risks and disease outcomes. Considering cardiac arrest, they can subsidize public policies, encourage future studies and training programs for CPR, thereby improving the prognosis of patients

    Search for scalar diphoton resonances in the mass range 65-600 GeV with the ATLAS detector in pp collision data at √s = 8  TeV

    Get PDF
    A search for scalar particles decaying via narrow resonances into two photons in the mass range 65–600 GeV is performed using 20.3  fb−¹ of √s=8  TeV pp collision data collected with the ATLAS detector at the Large Hadron Collider. The recently discovered Higgs boson is treated as a background. No significant evidence for an additional signal is observed. The results are presented as limits at the 95% confidence level on the production cross section of a scalar boson times branching ratio into two photons, in a fiducial volume where the reconstruction efficiency is approximately independent of the event topology. The upper limits set extend over a considerably wider mass range than previous searches

    withdrawn 2017 hrs ehra ecas aphrs solaece expert consensus statement on catheter and surgical ablation of atrial fibrillation

    Get PDF
    n/

    Monitoring and data quality assessment of the ATLAS liquid argon calorimeter

    Get PDF
    The liquid argon calorimeter is a key component of the ATLAS detector installed at the CERN Large Hadron Collider. The primary purpose of this calorimeter is the measurement of electron and photon kinematic properties. It also provides a crucial input for measuring jets and missing transverse momentum. An advanced data monitoring procedure was designed to quickly identify issues that would affect detector performance and ensure that only the best quality data are used for physics analysis. This article presents the validation procedure developed during the 2011 and 2012 LHC data-taking periods, in which more than 98% of the proton-proton luminosity recorded by ATLAS at a centre-of-mass energy of 7-8 TeV had calorimeter data quality suitable for physics analysis
    corecore