147 research outputs found

    Phosphorus and water recovery by a novel osmotic membrane bioreactor-reverse osmosis system

    Get PDF
    © 2015. An osmotic membrane bioreactor-reverse osmosis (OMBR-RO) hybrid system integrated with periodic microfiltration (MF) extraction was evaluated for simultaneous phosphorus and clean water recovery from raw sewage. In this hybrid system, the forward osmosis membrane effectively retained inorganic salts and phosphate in the bioreactor, while the MF membrane periodically bled them out for phosphorus recovery with pH adjustment. The RO process was used for draw solute recovery and clean water production. Results show that phosphorus recuperation from the MF permeate was most effective when the solution pH was adjusted to 10, whereby the recovered precipitate contained 15-20% (wt/wt) of phosphorus. Periodic MF extraction also limited salinity build-up in the bioreactor, resulting in a stable biological performance and an increase in water flux during OMBR operation. Despite the build-up of organic matter and ammonia in the draw solution, OMBR-RO allowed for the recovery of high quality reused water

    Impact of simultaneous retention of micropollutants and laccase on micropollutant degradation in enzymatic membrane bioreactor

    Get PDF
    © 2018 This study systematically compares the performance of ultrafiltration (UF) and nanofiltration (NF) based enzymatic membrane bioreactors (EMBRs) for the degradation of five micropollutants, namely atrazine, carbamazepine, sulfamethoxazole, diclofenac and oxybenzone to elucidate the impact of effective membrane retention of micropollutants on their degradation. Based on the permeate quality, NF-EMBR achieved 92–99.9% micropollutant removal (i.e., biodegradation + membrane retention), while the removal of these micropollutants by UF-EMBR varied from 20 to 85%. Mass balance analysis revealed that micropollutant degradation was improved by 15–30% in NF-EMBR as compared to UF-EMBR, which could be attributed to the prolonged contact time between laccase and micropollutants following their effective retention by the NF membrane. A small decline in permeate flux was observed during EMBR operation. However, the flux could be recovered by flushing the membrane with permeate

    Effects among healthy subjects of the duration of regularly practicing a guided imagery program

    Get PDF
    BACKGROUND: We examined a large number of healthy adults in the general community who had individually participated in a guided imagery (GI) program daily and for various durations, to examine the psychophysiological effects of a GI program within a healthy group. METHODS: We studied 176 subjects who had participated in sessions that were part of a guided imagery program, and who had practiced GI at home for 20 minutes once daily in a quiet place after mastering GI in the group sessions. The average duration of GI practiced at home was 6.88 ± 14.06 months (n = 138, range: 0 to 72). The Multiple Mood Scale (MMS), Betts (1909) Shortened Questionnaire on Mental Imagery (QMI), and a visual analog scale (VAS) of imagery vividness, salivary cortisol (C(S)) levels, general stress and general health were used in the sessions. RESULTS: We examined the relationship between the duration of daily GI practiced at home and MMS, QMI, C(S), general health, and general stress at baseline. The subjects who had practiced GI at home longer had lower negative mood scores at baseline and lower severity of stress, and higher positive mood at baseline (both at a session and at home), general health, and QMI scores at baseline. The MMS change during a session and the duration of daily GI practiced at home were not correlated. Repeated-measures analysis of covariance showed that the duration of daily GI practiced as the covariate was not associated with changes in the three C(S )levels. CONCLUSION: Although regularly practicing a GI program daily for 20 min did not affect the C(S )level or mood during a GI session for several hours, it kept a good condition of the general mental, physical well-being and their overall stress of the practitioners as they had practiced it for long duration. We postulate that subjects who have the high ability of imaging vividness showed the better mood, health status and less stress than those subjects who have the low ability of it did. The ability of image vividness of the long-term regular practitioners of GI was higher than its short-term or inexperienced practitioners, which allowed practitioners to produce more comfortable imagery. Consequently, the longer the duration that they had practiced GI program once a day regularly, the lower scores of their stress were and the higher scores of their health were. We suggest that the regular daily practice of a GI program might be connected to less stress and better health

    The genetics of chronic obstructive pulmonary disease

    Get PDF
    Chronic obstructive pulmonary disease (COPD) is a heterogeneous disease caused by the interaction of genetic susceptibility and environmental influences. There is increasing evidence that genes link to disease pathogenesis and heterogeneity by causing variation in protease anti-protease systems, defence against oxidative stress and inflammation. The main methods of genomic research for complex disease traits are described, together with the genes implicated in COPD thus far, their roles in disease causation and the future for this area of investigation

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Pan-cancer analysis of whole genomes

    Get PDF
    Cancer is driven by genetic change, and the advent of massively parallel sequencing has enabled systematic documentation of this variation at the whole-genome scale(1-3). Here we report the integrative analysis of 2,658 whole-cancer genomes and their matching normal tissues across 38 tumour types from the Pan-Cancer Analysis of Whole Genomes (PCAWG) Consortium of the International Cancer Genome Consortium (ICGC) and The Cancer Genome Atlas (TCGA). We describe the generation of the PCAWG resource, facilitated by international data sharing using compute clouds. On average, cancer genomes contained 4-5 driver mutations when combining coding and non-coding genomic elements; however, in around 5% of cases no drivers were identified, suggesting that cancer driver discovery is not yet complete. Chromothripsis, in which many clustered structural variants arise in a single catastrophic event, is frequently an early event in tumour evolution; in acral melanoma, for example, these events precede most somatic point mutations and affect several cancer-associated genes simultaneously. Cancers with abnormal telomere maintenance often originate from tissues with low replicative activity and show several mechanisms of preventing telomere attrition to critical levels. Common and rare germline variants affect patterns of somatic mutation, including point mutations, structural variants and somatic retrotransposition. A collection of papers from the PCAWG Consortium describes non-coding mutations that drive cancer beyond those in the TERT promoter(4); identifies new signatures of mutational processes that cause base substitutions, small insertions and deletions and structural variation(5,6); analyses timings and patterns of tumour evolution(7); describes the diverse transcriptional consequences of somatic mutation on splicing, expression levels, fusion genes and promoter activity(8,9); and evaluates a range of more-specialized features of cancer genomes(8,10-18).Peer reviewe

    Muon reconstruction and identification efficiency in ATLAS using the full Run 2 pp collision data set at \sqrt{s}=13 TeV

    Get PDF
    This article documents the muon reconstruction and identification efficiency obtained by the ATLAS experiment for 139 \hbox {fb}^{-1} of pp collision data at \sqrt{s}=13 TeV collected between 2015 and 2018 during Run 2 of the LHC. The increased instantaneous luminosity delivered by the LHC over this period required a reoptimisation of the criteria for the identification of prompt muons. Improved and newly developed algorithms were deployed to preserve high muon identification efficiency with a low misidentification rate and good momentum resolution. The availability of large samples of Z\rightarrow \mu \mu and J/\psi \rightarrow \mu \mu decays, and the minimisation of systematic uncertainties, allows the efficiencies of criteria for muon identification, primary vertex association, and isolation to be measured with an accuracy at the per-mille level in the bulk of the phase space, and up to the percent level in complex kinematic configurations. Excellent performance is achieved over a range of transverse momenta from 3 GeV to several hundred GeV, and across the full muon detector acceptance of |\eta |<2.7
    corecore