879 research outputs found

    Physical activity and anxiety : A perspective from the World Health Survey

    Get PDF
    Background: Despite the known benefits of physical activity (PA) among people with anxiety, little is known about PA levels in people with anxiety at the population level. This study explored the global prevalence of anxiety and its association with PA. Methods: Cross-sectional, community-based data from the World Health Survey was analyzed. Prevalence of anxiety was estimated for 237,964 individuals (47 countries). PA was categorized as low, moderate, and high based on the International Physical Activity Questionnaire (short form). The association between PA and anxiety was assessed by multivariable logistic regression. Results: The overall global prevalence of anxiety was 11.4% (47 countries). Across 38 countries with available data on PA, 62.5%, 20.2%, and 17.3% of the sample engaged in high, moderate, and low levels of PA respectively. The prevalence of low physical activity in those with and without anxiety was 22.9% vs. 16.6% (p <0.001) (38 countries, n=184,920). In the pooled model adjusted for socio-demographics, depression, and country, individuals engaging in low PA (vs. high PA) had 1.32 (95% CI=1.17-1.47) times higher odds for anxiety than those with high PA. Female sex, older age, lower education and wealth, and depression were also associated with low PA. At the individual country level, there was a significant positive association between low PA and anxiety in 17 of the 38 countries. Conclusion: Low PA levels are associated with increased prevalence of anxiety. There is a need for longitudinal research to establish the directionality of the relationships observed.Peer reviewe

    A Description of Quasar Variability Measured Using Repeated SDSS and POSS Imaging

    Get PDF
    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining ~25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000A to 6000A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic time scale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on time scales of ~5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from PTF and LSST.Comment: 33 pages, 19 figures, replaced with accepted version. Catalog is available at http://www.astro.washington.edu/users/ivezic/macleod/qso_dr7

    Measuring Lensing Magnification of Quasars by Large Scale Structure using the Variability-Luminosity Relation

    Full text link
    We introduce a technique to measure gravitational lensing magnification using the variability of type I quasars. Quasars' variability amplitudes and luminosities are tightly correlated, on average. Magnification due to gravitational lensing increases the quasars' apparent luminosity, while leaving the variability amplitude unchanged. Therefore, the mean magnification of an ensemble of quasars can be measured through the mean shift in the variability-luminosity relation. As a proof of principle, we use this technique to measure the magnification of quasars spectroscopically identified in the Sloan Digital Sky Survey, due to gravitational lensing by galaxy clusters in the SDSS MaxBCG catalog. The Palomar-QUEST Variability Survey, reduced using the DeepSky pipeline, provides variability data for the sources. We measure the average quasar magnification as a function of scaled distance (r/R200) from the nearest cluster; our measurements are consistent with expectations assuming NFW cluster profiles, particularly after accounting for the known uncertainty in the clusters' centers. Variability-based lensing measurements are a valuable complement to shape-based techniques because their systematic errors are very different, and also because the variability measurements are amenable to photometric errors of a few percent and to depths seen in current wide-field surveys. Given the data volume expected from current and upcoming surveys, this new technique has the potential to be competitive with weak lensing shear measurements of large scale structure.Comment: Accepted for publication in Ap

    Spectral variability of quasars from multi-epoch photometric data in the Sloan Digital Sky Survey Stripe 82

    Full text link
    We present a new approach to analysing the dependence of quasar variability on rest-frame wavelengths. We exploited the spectral archive of the Sloan Digital Sky Survey (SDSS) to create a sample of more than 9000 quasars in the Stripe 82. The quasar catalogue was matched with the Light Motion Curve Catalogue for SDSS Stripe 82 and individual first-order structure functions were computed. The structure functions are used to create a variability indicator that is related to the same intrinsic timescales for all quasars (1 to 2 yr in the rest frame). We study the variability ratios for adjacent SDSS filter bands as a function of redshift. While variability is almost always stronger in the bluer passband compared to the redder, the variability ratio depends on whether strong emission lines contribute to either one band or the other. The variability ratio-redshift relations resemble the corresponding colour index-redshift relations. From the comparison with Monte Carlo simulations of variable quasar spectra we find that the observed variability ratio-redshift relations are closely fitted assuming that (a) the r.m.s. fluctuation of the quasar continuum follows a power law-dependence on the intrinsic wavelength with an exponent -2 (i.e., bluer when brighter) and (b) the variability of the emission line flux is only about 10% of that of the underlying continuum. These results, based upon the photometry of more than 8000 quasars, confirm the previous findings by Wilhite et al. (2005) from 315 quasars with repeated SDSS spectroscopy. Finally, we find that quasars with unusual spectra and weak emission lines tend to have less variability than conventional quasars. This trend is opposite to what is expected from the dilution effect of variability due to line emission and may be indicative of high Eddington ratios in these unconventinal quasars.Comment: Accepted for publication in Astronomy and Astrophysic

    Nanostructured luminescently labeled nucleic acids

    Get PDF
    Important and emerging trends at the interface of luminescence, nucleic acids and nanotechnology are: (i) the conventional luminescence labeling of nucleic acid nanostructures (e.g. DNA tetrahedron); (ii) the labeling of bulk nucleic acids (e.g. single‐stranded DNA, double‐stranded DNA) with nanostructured luminescent labels (e.g. copper nanoclusters); and (iii) the labeling of nucleic acid nanostructures (e.g. origami DNA) with nanostructured luminescent labels (e.g. silver nanoclusters). This review surveys recent advances in these three different approaches to the generation of nanostructured luminescently labeled nucleic acids, and includes both direct and indirect labeling methods

    First report of generalized face processing difficulties in möbius sequence.

    Get PDF
    Reverse simulation models of facial expression recognition suggest that we recognize the emotions of others by running implicit motor programmes responsible for the production of that expression. Previous work has tested this theory by examining facial expression recognition in participants with Möbius sequence, a condition characterized by congenital bilateral facial paralysis. However, a mixed pattern of findings has emerged, and it has not yet been tested whether these individuals can imagine facial expressions, a process also hypothesized to be underpinned by proprioceptive feedback from the face. We investigated this issue by examining expression recognition and imagery in six participants with Möbius sequence, and also carried out tests assessing facial identity and object recognition, as well as basic visual processing. While five of the six participants presented with expression recognition impairments, only one was impaired at the imagery of facial expressions. Further, five participants presented with other difficulties in the recognition of facial identity or objects, or in lower-level visual processing. We discuss the implications of our findings for the reverse simulation model, and suggest that facial identity recognition impairments may be more severe in the condition than has previously been noted

    Advanced Fluorescence Microscopy Techniques-FRAP, FLIP, FLAP, FRET and FLIM

    Get PDF
    Fluorescence microscopy provides an efficient and unique approach to study fixed and living cells because of its versatility, specificity, and high sensitivity. Fluorescence microscopes can both detect the fluorescence emitted from labeled molecules in biological samples as images or photometric data from which intensities and emission spectra can be deduced. By exploiting the characteristics of fluorescence, various techniques have been developed that enable the visualization and analysis of complex dynamic events in cells, organelles, and sub-organelle components within the biological specimen. The techniques described here are fluorescence recovery after photobleaching (FRAP), the related fluorescence loss in photobleaching (FLIP), fluorescence localization after photobleaching (FLAP), Forster or fluorescence resonance energy transfer (FRET) and the different ways how to measure FRET, such as acceptor bleaching, sensitized emission, polarization anisotropy, and fluorescence lifetime imaging microscopy (FLIM). First, a brief introduction into the mechanisms underlying fluorescence as a physical phenomenon and fluorescence, confocal, and multiphoton microscopy is given. Subsequently, these advanced microscopy techniques are introduced in more detail, with a description of how these techniques are performed, what needs to be considered, and what practical advantages they can bring to cell biological research

    The Role of Particulate Matter-Associated Zinc in Cardiac Injury in Rats

    Get PDF
    Background: Exposure to particulate matter (PM) has been associated with increased cardiovascular morbidity; however, causative components are unknown. Zinc is a major element detected at high levels in urban air.Objective We investigated the role of PM-associated zinc in cardiac injury. Methods: We repeatedly exposed 12- to 14-week-old male Wistar Kyoto rats intratracheally (1×/week for 8 or16 weeks) to a) saline (control); b) PM having no soluble zinc (Mount St. Helens ash, MSH); or c) whole-combustion PM suspension containing 14.5 μg/mg of water-soluble zinc at high dose (PM-HD) and d ) low dose (PM-LD), e) the aqueous fraction of this suspension (14.5 μg/mg of soluble zinc) (PM-L), or f ) zinc sulfate (rats exposed for 8 weeks received double the concentration of all PM components of rats exposed for 16 weeks). Results: Pulmonary inflammation was apparent in all exposure groups when compared with saline (8 weeks greater than 16 weeks). PM with or without zinc, or with zinc alone caused small increases in focal subepicardial inflammation, degeneration, and fibrosis. Lesions were not detected in controls at 8 weeks but were noted at 16 weeks. We analyzed mitochondrial DNA damage using quantitative polymerase chain reaction and found that all groups except MSH caused varying degrees of damage relative to control. Total cardiac aconitase activity was inhibited in rats receiving soluble zinc. Expression array analysis of heart tissue revealed modest changes in mRNA for genes involved in signaling, ion channels function, oxidative stress, mitochondrial fatty acid metabolism, and cell cycle regulation in zinc but not in MSH-exposed rats. Conclusion: These results suggest that water-soluble PM-associated zinc may be one of the causal components involved in PM cardiac effects

    Interference Screw vs. Suture Anchor Fixation for Open Subpectoral Biceps Tenodesis: Does it Matter?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Bioabsorbable interference screw fixation has superior biomechanical properties compared to suture anchor fixation for biceps tenodesis. However, it is unknown whether fixation technique influences clinical results.</p> <p>Hypothesis</p> <p>We hypothesize that subpectoral interference screw fixation offers relevant clinical advantages over suture anchor fixation for biceps tenodesis.</p> <p>Study Design</p> <p>Case Series.</p> <p>Methods</p> <p>We performed a retrospective review of a consecutive series of 88 patients receiving open subpectoral biceps tenodesis with either interference screw fixation (34 patients) or suture anchor fixation (54 patients). Average follow up was 13 months. Outcomes included Visual Analogue Pain Scale (0–10), ASES score, modified Constant score, pain at the tenodesis site, failure of fixation, cosmesis, deformity (popeye) and complications.</p> <p>Results</p> <p>There were no failures of fixation in this study. All patients showed significant improvement between their preoperative and postoperative status with regard to pain, ASES score, and abbreviated modified Constant scores. When comparing IF screw versus anchor outcomes, there was no statistical significance difference for VAS (p = 0.4), ASES score (p = 0.2), and modified Constant score (P = 0.09). One patient (3%) treated with IF screw complained of persistent bicipital groove tenderness, versus four patients (7%) in the SA group (nonsignificant).</p> <p>Conclusion</p> <p>Subpectoral biceps tenodesis reliably relieves pain and improves function. There was no statistically significant difference in the outcomes studied between the two fixation techniques. Residual pain at the site of tenodesis may be an issue when suture anchors are used in the subpectoral location.</p
    corecore