425 research outputs found
Pediculosis and the Pediatrician
Head lice commonly evoke feelings of disgust, revulsion, anger, and shame among parents and patients. There should, however, be no great cause for such alarm if a physician suspects pediculosis capitis. The recent introduction of several new pediculicidal drugs now allows a choice among four distinct therapeutic agents, which should substantially improve control of isolated cases and epidemics. Physicians must be aware that consumer groups are pressing public health authorities and drug manufacturers to establish proper treatment standards and safety warnings for the use of these agents. In addition, some controversy surrounds the use of lindane in children. This paper reviews the epidemiology and clinical appearance of pediculosis capitis in children, with emphasis on these recent developments. Pubic lice ( Phthirus pubis ) and body lice ( Pedicutus humanus corporis ), both of which are much less common pediatric infestations, are mentioned only briefly.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72607/1/j.1525-1470.1984.tb00447.x.pd
Superparamagnetic properties of hemozoin
We report that hemozoin nanocrystals demonstrate superparamagnetic properties, with direct measurements of the synthetic hemozoin magnetization. The results show that the magnetic permeability constant varies from mu = 4585 (at -20 degrees C) to 3843 (+20 degrees C), with the values corresponding to a superparamagnetic system. Similar results were obtained from the analysis of the diffusion separation of natural hemozoin nanocrystals in the magnetic field gradient, with mu = 6783 exceeding the value obtained in direct measurements by the factor of 1.8. This difference is interpreted in terms of structural differences between the synthetic and natural hemozoin. The ab initio analysis of the hemozoin elementary cell showed that the Fe3+ ion is in the high-spin state (S = 5/2), while the exchange interaction between Fe3+ electron-spin states was much stronger than k(B)T at room temperature. Thus, the spin dynamics of the neighboring Fe3+ ions are strongly correlated, lending support to the superparamagnetism
Multiple factors influence compliance with colorectal cancer staging recommendations: an exploratory study
<p>Abstract</p> <p>Background</p> <p>For patients with colorectal cancer (CRC) retrieval by surgeons, and assessment by pathologists of at least 12 lymph nodes (LNs) predicts the need for adjuvant treatment and improved survival. Different interventions (educational presentation, engaging clinical opinion leaders, performance data sent to hospital executives) to improve compliance with this practice had variable results. This exploratory study examined factors hypothesized to have influenced the outcome of those interventions.</p> <p>Methods</p> <p>Semi-structured interviews were conducted with 26 surgeons and pathologists at eleven hospitals. Clinicians were identified by intervention organizers, public licensing body database, and referral from interviewees. An interview guide incorporating open-ended questions was pilot-tested on one surgeon and pathologist. A single investigator conducted all interviews by phone. Transcripts were analyzed independently by two investigators using a grounded approach,ho then compared findings to resolve differences.</p> <p>Results</p> <p>Improvements in LN staging practice may have occurred largely due to educational presentations that created awareness, and self-initiated changes undertaken by pathologists. Executives that received performance data may not have shared this with staff, and opinion leaders engaged to promote compliance may not have fulfilled their roles. Barriers to change that are potentially amenable to quality improvement included perceptions about the practice (perceived lack of evidence for the need to examine at least 12 LNs) and associated responsibilities (blaming other profession), technical issues (need for pathology assistants, better clearing solutions and laboratory facilities), and a lack of organizational support for multidisciplinary interaction (little communication between surgeons and pathologists) or quality improvement (no change leaders or capacity for monitoring).</p> <p>Conclusion</p> <p>Use of an exploratory approach provided an in-depth view of the way that numerous factors amenable to quality improvement influenced the adoption of new CRC LN staging recommendations. Continued interventions targeting physicians and executives, in the absence of a receptive organizational infrastructure, may be fruitless. Individualized rather than regional or punitive performance data, coupled with increased organizational capacity for change may stimulate greater surgical and organizational response to quality improvement. Descriptive or experimental studies are needed to test these hypotheses.</p
Angular and Current-Target Correlations in Deep Inelastic Scattering at HERA
Correlations between charged particles in deep inelastic ep scattering have
been studied in the Breit frame with the ZEUS detector at HERA using an
integrated luminosity of 6.4 pb-1. Short-range correlations are analysed in
terms of the angular separation between current-region particles within a cone
centred around the virtual photon axis. Long-range correlations between the
current and target regions have also been measured. The data support
predictions for the scaling behaviour of the angular correlations at high Q2
and for anti-correlations between the current and target regions over a large
range in Q2 and in the Bjorken scaling variable x. Analytic QCD calculations
and Monte Carlo models correctly describe the trends of the data at high Q2,
but show quantitative discrepancies. The data show differences between the
correlations in deep inelastic scattering and e+e- annihilation.Comment: 26 pages including 10 figures (submitted to Eur. J. Phys. C
Plastisol Foaming Process. Decomposition of the Foaming Agent, Polymer Behavior in the Corresponding Temperature Range and Resulting Foam Properties
The decomposition of azodicarbonamide, used as foaming agent in PVC - plasticizer (1/1) plastisols was studied by DSC. Nineteen different plasticizers, all belonging to the ester family, two being polymeric (polyadipates), were compared. The temperature of maximum decomposition rate (in anisothermal regime at 5 K min-1 scanning rate), ranges between 434 and 452 K. The heat of decomposition ranges between 8.7 and 12.5 J g -1. Some trends of variation of these parameters appear significant and are discussed in terms of solvent (matrix) and viscosity effects on the decomposition reactions. The shear modulus at 1 Hz frequency was determined at the temperature of maximum rate of foaming agent decomposition, and differs significantly from a sample to another. The foam density was determined at ambient temperature and the volume fraction of bubbles was used as criterion to judge the efficiency of the foaming process. The results reveal the existence of an optimal shear modulus of the order of 2 kPa that corresponds roughly to plasticizer molar masses of the order of 450 ± 50 g mol-1. Heavier plasticizers, especially polymeric ones are too difficult to deform. Lighter plasticizers such as diethyl phthalate (DEP) deform too easily and presumably facilitate bubble collapse
Measurement of the Bottom-Strange Meson Mixing Phase in the Full CDF Data Set
We report a measurement of the bottom-strange meson mixing phase \beta_s
using the time evolution of B0_s -> J/\psi (->\mu+\mu-) \phi (-> K+ K-) decays
in which the quark-flavor content of the bottom-strange meson is identified at
production. This measurement uses the full data set of proton-antiproton
collisions at sqrt(s)= 1.96 TeV collected by the Collider Detector experiment
at the Fermilab Tevatron, corresponding to 9.6 fb-1 of integrated luminosity.
We report confidence regions in the two-dimensional space of \beta_s and the
B0_s decay-width difference \Delta\Gamma_s, and measure \beta_s in [-\pi/2,
-1.51] U [-0.06, 0.30] U [1.26, \pi/2] at the 68% confidence level, in
agreement with the standard model expectation. Assuming the standard model
value of \beta_s, we also determine \Delta\Gamma_s = 0.068 +- 0.026 (stat) +-
0.009 (syst) ps-1 and the mean B0_s lifetime, \tau_s = 1.528 +- 0.019 (stat) +-
0.009 (syst) ps, which are consistent and competitive with determinations by
other experiments.Comment: 8 pages, 2 figures, Phys. Rev. Lett 109, 171802 (2012
Precise measurement of the W-boson mass with the CDF II detector
We have measured the W-boson mass MW using data corresponding to 2.2/fb of
integrated luminosity collected in proton-antiproton collisions at 1.96 TeV
with the CDF II detector at the Fermilab Tevatron collider. Samples consisting
of 470126 W->enu candidates and 624708 W->munu candidates yield the measurement
MW = 80387 +- 12 (stat) +- 15 (syst) = 80387 +- 19 MeV. This is the most
precise measurement of the W-boson mass to date and significantly exceeds the
precision of all previous measurements combined
Measurement of the Forward-Backward Asymmetry in the B -> K(*) mu+ mu- Decay and First Observation of the Bs -> phi mu+ mu- Decay
We reconstruct the rare decays , , and in a data sample
corresponding to collected in collisions at
by the CDF II detector at the Fermilab Tevatron
Collider. Using and decays we report the branching ratios. In addition, we report
the measurement of the differential branching ratio and the muon
forward-backward asymmetry in the and decay modes, and the
longitudinal polarization in the decay mode with respect to the squared
dimuon mass. These are consistent with the theoretical prediction from the
standard model, and most recent determinations from other experiments and of
comparable accuracy. We also report the first observation of the {\mathcal{B}}(B^0_s \to
\phi\mu^+\mu^-) = [1.44 \pm 0.33 \pm 0.46] \times 10^{-6}27 \pm 6B^0_s$ decay observed.Comment: 7 pages, 2 figures, 3 tables. Submitted to Phys. Rev. Let
Search for a New Heavy Gauge Boson Wprime with Electron + missing ET Event Signature in ppbar collisions at sqrt(s)=1.96 TeV
We present a search for a new heavy charged vector boson decaying
to an electron-neutrino pair in collisions at a center-of-mass
energy of 1.96\unit{TeV}. The data were collected with the CDF II detector
and correspond to an integrated luminosity of 5.3\unit{fb}^{-1}. No
significant excess above the standard model expectation is observed and we set
upper limits on . Assuming standard
model couplings to fermions and the neutrino from the boson decay to
be light, we exclude a boson with mass less than
1.12\unit{TeV/}c^2 at the 95\unit{%} confidence level.Comment: 7 pages, 2 figures Submitted to PR
- âŠ