326 research outputs found

    Structure of a crystal form of human methemoglobin indicative of fiber formation

    Get PDF
    Human methemoglobin was crystallized in a unique unit cell and its structure was solved by molecular replacement. The hexagonal unit cell has unit-cell parameters a = b = 54.6, c = 677.4 Å, with symmetry consistent with space group P6₁22. The unit cell has the second highest aspect ratio of all unit cells contained in the PDB. The 12 molecules in the unit cell describe a right-handed helical filament having no polarity, which is different from the filament composed of HbS fibers, which is the only other well characterized fiber of human hemoglobin. The filaments reported here can be related to canonical sickle-cell hemoglobin filaments and to an alternative sickle-cell filament deduced from fiber diffraction by slight modifications of intermolecular contacts

    Choosing how to choose : Institutional pressures affecting the adoption of personnel selection procedures

    Get PDF
    The gap between science and practice in personnel selection is an ongoing concern of human resource management. This paper takes Oliver´s framework of organizations´ strategic responses to institutional pressures as a basis for outlining the diverse economic and social demands that facilitate or inhibit the application of scientifically recommended selection procedures. Faced with a complex network of multiple requirements, practitioners make more diverse choices in response to any of these pressures than has previously been acknowledged in the scientific literature. Implications for the science-practitioner gap are discussed

    Measurement of the Bottom-Strange Meson Mixing Phase in the Full CDF Data Set

    Get PDF
    We report a measurement of the bottom-strange meson mixing phase \beta_s using the time evolution of B0_s -> J/\psi (->\mu+\mu-) \phi (-> K+ K-) decays in which the quark-flavor content of the bottom-strange meson is identified at production. This measurement uses the full data set of proton-antiproton collisions at sqrt(s)= 1.96 TeV collected by the Collider Detector experiment at the Fermilab Tevatron, corresponding to 9.6 fb-1 of integrated luminosity. We report confidence regions in the two-dimensional space of \beta_s and the B0_s decay-width difference \Delta\Gamma_s, and measure \beta_s in [-\pi/2, -1.51] U [-0.06, 0.30] U [1.26, \pi/2] at the 68% confidence level, in agreement with the standard model expectation. Assuming the standard model value of \beta_s, we also determine \Delta\Gamma_s = 0.068 +- 0.026 (stat) +- 0.009 (syst) ps-1 and the mean B0_s lifetime, \tau_s = 1.528 +- 0.019 (stat) +- 0.009 (syst) ps, which are consistent and competitive with determinations by other experiments.Comment: 8 pages, 2 figures, Phys. Rev. Lett 109, 171802 (2012

    Immediate newborn care and breastfeeding: EN-BIRTH multi-country validation study

    Get PDF
    Background Immediate newborn care (INC) practices, notably early initiation of breastfeeding (EIBF), are fundamental for newborn health. However, coverage tracking currently relies on household survey data in many settings. “Every Newborn Birth Indicators Research Tracking in Hospitals” (EN-BIRTH) was an observational study validating selected maternal and newborn health indicators. This paper reports results for EIBF. Methods The EN-BIRTH study was conducted in five public hospitals in Bangladesh, Nepal, and Tanzania, from July 2017 to July 2018. Clinical observers collected tablet-based, time-stamped data on EIBF and INC practices (skin-to-skin within 1 h of birth, drying, and delayed cord clamping). To assess validity of EIBF measurement, we compared observation as gold standard to register records and women’s exit-interview survey reports. Percent agreement was used to assess agreement between EIBF and INC practices. Kaplan Meier survival curves showed timing. Qualitative interviews were conducted to explore barriers/enablers to register recording. Results Coverage of EIBF among 7802 newborns observed for ≥1 h was low (10.9, 95% CI 3.8–21.0). Survey-reported (53.2, 95% CI 39.4–66.8) and register-recorded results (85.9, 95% CI 58.1–99.6) overestimated coverage compared to observed levels across all hospitals. Registers did not capture other INC practices apart from breastfeeding. Agreement of EIBF with other INC practices was high for skin-to-skin (69.5–93.9%) at four sites, but fair/poor for delayed cord-clamping (47.3–73.5%) and drying (7.3–29.0%). EIBF and skin-to-skin were the most delayed and EIBF rarely happened after caesarean section (0.5–3.6%). Qualitative findings suggested that focusing on accuracy, as well as completeness, contributes to higher quality with register reporting. Conclusions Our study highlights the importance of tracking EIBF despite measurement challenges and found low coverage levels, particularly after caesarean births. Both survey-reported and register-recorded data over-estimated coverage. EIBF had a strong agreement with skin-to-skin but is not a simple tracer for other INC indicators. Other INC practices are challenging to measure in surveys, not included in registers, and are likely to require special studies or audits. Continued focus on EIBF is crucial to inform efforts to improve provider practices and increase coverage. Investment and innovation are required to improve measurement

    Antibiotic use for inpatient newborn care with suspected infection: EN-BIRTH multi-country validation study

    Get PDF
    Background An estimated 30 million neonates require inpatient care annually, many with life-threatening infections. Appropriate antibiotic management is crucial, yet there is no routine measurement of coverage. The Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study aimed to validate maternal and newborn indicators to inform measurement of coverage and quality of care. This paper reports validation of reported antibiotic coverage by exit survey of mothers for hospitalized newborns with clinically-defined infections, including sepsis, meningitis, and pneumonia. Methods EN-BIRTH study was conducted in five hospitals in Bangladesh, Nepal, and Tanzania (July 2017–July 2018). Neonates were included based on case definitions to focus on term/near-term, clinically-defined infection syndromes (sepsis, meningitis, and pneumonia), excluding major congenital abnormalities. Clinical management was abstracted from hospital inpatient case notes (verification) which was considered as the gold standard against which to validate accuracy of women’s report. Exit surveys were conducted using questions similar to The Demographic and Health Surveys (DHS) approach for coverage of childhood pneumonia treatment. We compared survey-report to case note verified, pooled across the five sites using random effects meta-analysis. Results A total of 1015 inpatient neonates admitted in the five hospitals met inclusion criteria with clinically-defined infection syndromes. According to case note verification, 96.7% received an injectable antibiotic, although only 14.5% of them received the recommended course of at least 7 days. Among women surveyed (n = 910), 98.8% (95% CI: 97.8–99.5%) correctly reported their baby was admitted to a neonatal ward. Only 47.1% (30.1–64.5%) reported their baby’s diagnosis in terms of sepsis, meningitis, or pneumonia. Around three-quarters of women reported their baby received an injection whilst in hospital, but 12.3% reported the correct antibiotic name. Only 10.6% of the babies had a blood culture and less than 1% had a lumbar puncture. Conclusions Women’s report during exit survey consistently underestimated the denominator (reporting the baby had an infection), and even more so the numerator (reporting known injectable antibiotics). Admission to the neonatal ward was accurately reported and may have potential as a contact point indicator for use in household surveys, similar to institutional births. Strengthening capacity and use of laboratory diagnostics including blood culture are essential to promote appropriate use of antibiotics. To track quality of neonatal infection management, we recommend using inpatient records to measure specifics, requiring more research on standardised inpatient records

    Kangaroo mother care: EN-BIRTH multi-country validation study

    Get PDF
    Background Kangaroo mother care (KMC) reduces mortality among stable neonates ≤2000 g. Lack of data tracking coverage and quality of KMC in both surveys and routine information systems impedes scale-up. This paper evaluates KMC measurement as part of the Every Newborn Birth Indicators Research Tracking in Hospitals (EN-BIRTH) study. Methods The EN-BIRTH observational mixed-methods study was conducted in five hospitals in Bangladesh, Nepal and Tanzania from 2017 to 2018. Clinical observers collected time-stamped data as gold standard for mother-baby pairs in KMC wards/corners. To assess accuracy, we compared routine register-recorded and women’s exit survey-reported coverage to observed data, using different recommended denominator options (≤2000 g and ≤ 2499 g). We analysed gaps in quality of provision and experience of KMC. In the Tanzanian hospitals, we assessed daily skin-to-skin duration/dose and feeding frequency. Qualitative data were collected from health workers and data collectors regarding barriers and enablers to routine register design, filling and use. Results Among 840 mother-baby pairs, compared to observed 100% coverage, both exit-survey reported (99.9%) and register-recorded coverage (92.9%) were highly valid measures with high sensitivity. KMC specific registers outperformed general registers. Enablers to register recording included perceptions of data usefulness, while barriers included duplication of data elements and overburdened health workers. Gaps in KMC quality were identified for position components including wearing a hat. In Temeke Tanzania, 10.6% of babies received daily KMC skin-to-skin duration/dose of ≥20 h and a further 75.3% received 12–19 h. Regular feeding ≥8 times/day was observed for 36.5% babies in Temeke Tanzania and 14.6% in Muhimbili Tanzania. Cup-feeding was the predominant assisted feeding method. Family support during admission was variable, grandmothers co-provided KMC more often in Bangladesh. No facility arrangements for other family members were reported by 45% of women at exit survey. Conclusions Routine hospital KMC register data have potential to track coverage from hospital KMC wards/corners. Women accurately reported KMC at exit survey and evaluation for population-based surveys could be considered. Measurement of content, quality and experience of KMC need consensus on definitions. Prioritising further KMC measurement research is important so that high quality data can be used to accelerate scale-up of high impact care for the most vulnerable

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR
    • …
    corecore