286 research outputs found
Photodetachment of H near a partial reflecting surface
Theoretical and interpretative study on the subject of photodetachment of
H near a partial reflecting surface is presented, and the absorption
effect of the surface is investigated on the total and differential cross
sections using a theoretical imaging method. To understand the absorption
effect, a reflection parameter is introduced as a multiplicative factor to
the outgoing detached-electron wave of H propagating toward the wall. The
reflection parameter measures, how much electron wave would reflect from the
surface; K=0 corresponds to no reflection and K=1 corresponds to the total
reflection.Comment: 8 pages, 4 figure
CT-based texture analysis potentially provides prognostic information complementary to interim fdg-pet for patients with hodgkin's and aggressive non-hodgkin's lymphomas
OBJECTIVES: The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL).
METHODS: This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features.
RESULTS: A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET.
CONCLUSION: CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL
Investigation of structural and optoelectronic properties of BaThO3
Structural and optoelectronic properties of BaThO3 cubic perovskite are
calculated using all electrons full potential linearized augmented plane wave
(FP-LAPW) method. Wide and direct band gap, 5.7 eV, of the compound predicts
that it can be effectively used in UV based optoelectronic devices. Different
characteristic peaks in the wide UV range emerges mainly due to the transition
of electrons between valance band state O-p and conduction band states Ba-d,
Ba-f, Th-f and Th-d.Comment: 20 pages and 7 figure
Areas of normal pulmonary parenchyma on HRCT exhibit increased FDG PET signal in IPF patients
Purpose: Patients with idiopathic pulmonary fibrosis (IPF) show increased PET signal at sites of morphological abnormality on high-resolution computed tomography (HRCT). The purpose of this investigation was to investigate the PET signal at sites of normal-appearing lung on HRCT in IPF. Methods: Consecutive IPF patients (22 men, 3 women) were prospectively recruited. The patients underwent 18F-FDG PET/HRCT. The pulmonary imaging findings in the IPF patients were compared to the findings in a control population. Pulmonary uptake of 18F-FDG (mean SUV) was quantified at sites of morphologically normal parenchyma on HRCT. SUVs were also corrected for tissue fraction (TF). The mean SUV in IPF patients was compared with that in 25 controls (patients with lymphoma in remission or suspected paraneoplastic syndrome with normal PET/CT appearances). Results: The pulmonary SUV (mean ± SD) uncorrected for TF in the controls was 0.48 ± 0.14 and 0.78 ± 0.24 taken from normal lung regions in IPF patients (p < 0.001). The TF-corrected mean SUV in the controls was 2.24 ± 0.29 and 3.24 ± 0.84 in IPF patients (p < 0.001). Conclusion: IPF patients have increased pulmonary uptake of 18F-FDG on PET in areas of lung with a normal morphological appearance on HRCT. This may have implications for determining disease mechanisms and treatment monitoring. © 2013 The Author(s)
Comparison of PET/MRI With PET/CT in the Evaluation of Disease Status in Lymphoma
PURPOSE: The primary aim was to compare the diagnostic performance of PET/MRI (performed with basic anatomical MRI sequences) in detecting sites of disease in adult patients with lymphoma compared with the current standard of care, PET/CT. Secondary aims were to assess the additional value of diffusion-weighted imaging to PET/MRI in disease detection and to evaluate the relationship between the standardized uptake value on PET/MR and the apparent diffusion coefficient on diffusion-weighted imaging.
METHODS:
Sixty-eight studies in 66 consecutive patients with histologically proven Hodgkin or non-Hodgkin lymphoma were prospectively evaluated. Each patient had whole body PET/CT, followed by whole body PET/MR. Two experienced readers independently evaluated the PET/MRI studies, and two other experienced readers independently evaluated PET/CT. Site of lymphoma involvement and SUVmax at all nodal sites more avid than background liver were recorded. Readers provided stage (in baseline cases) and disease status (remission vs active disease). The apparent diffusion coefficient mean value corresponding to the most avid PET site of disease was recorded.
RESULTS:
Ninety-five nodal and 8 extranodal sites were identified on both PET/CT and PET/MRI. In addition, 3 nodal and 1 extranodal sites were identified on PET/MRI. For positive lesion detection, reader agreement in PET/MR was perfect between the 2 readers and almost perfect between PET/CT and PET/MR (k > 0.978). Intermodality agreement between PET/CT and PET/MRI was also near perfect to perfect for staging/disease status k = (0.979–1.000). SUVmax from PET/CT and PET/MRI correlated significantly (Spearman rho correlation coefficient, 0.842; P < 0.001). Diffusion-weighted imaging did not alter lesion detection or staging in any case. A negative correlation was demonstrated between ADC mean and SUVmax (Spearman rho correlation coefficient r, -0.642; P < 0.001).
CONCLUSIONS:
PET/MRI is a reliable alternative to PET/CT in the evaluation of patients with lymphoma. Diffusion-weighted imaging did not alter diagnostic accuracy. With comparable accuracy in detection of disease sites and added benefit of radiation dose reduction, PET/MRI has a potential to become part of routine lymphoma imaging
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
A multi-targeted approach to suppress tumor-promoting inflammation
Cancers harbor significant genetic heterogeneity and patterns of relapse following many therapies are due to evolved resistance to treatment. While efforts have been made to combine targeted therapies, significant levels of toxicity have stymied efforts to effectively treat cancer with multi-drug combinations using currently approved therapeutics. We discuss the relationship between tumor-promoting inflammation and cancer as part of a larger effort to develop a broad-spectrum therapeutic approach aimed at a wide range of targets to address this heterogeneity. Specifically, macrophage migration inhibitory factor, cyclooxygenase-2, transcription factor nuclear factor-κB, tumor necrosis factor alpha, inducible nitric oxide synthase, protein kinase B, and CXC chemokines are reviewed as important antiinflammatory targets while curcumin, resveratrol, epigallocatechin gallate, genistein, lycopene, and anthocyanins are reviewed as low-cost, low toxicity means by which these targets might all be reached simultaneously. Future translational work will need to assess the resulting synergies of rationally designed antiinflammatory mixtures (employing low-toxicity constituents), and then combine this with similar approaches targeting the most important pathways across the range of cancer hallmark phenotypes
Performance and Operation of the CMS Electromagnetic Calorimeter
The operation and general performance of the CMS electromagnetic calorimeter
using cosmic-ray muons are described. These muons were recorded after the
closure of the CMS detector in late 2008. The calorimeter is made of lead
tungstate crystals and the overall status of the 75848 channels corresponding
to the barrel and endcap detectors is reported. The stability of crucial
operational parameters, such as high voltage, temperature and electronic noise,
is summarised and the performance of the light monitoring system is presented
The CMS High Level Trigger System
The CMS Data Acquisition (DAQ) System relies on a purely software driven High Level Trigger (HLT) to reduce the full Level-1 accept rate of 100 kHz to approximately 100 Hz for archiving and later offline analysis. The HLT operates on the full information of events assembled by an event builder collecting detector data from the CMS front-end systems. The HLT software consists of a sequence of reconstruction and filtering modules executed on a farm of O(1000) CPUs built from commodity hardware. This paper presents the architecture of the CMS HLT, which integrates the CMS reconstruction framework in the online environment. The mechanisms to configure, control, and monitor the Filter Farm and the procedures to validate the filtering code within the DAQ environment are described
- …