168 research outputs found

    Clinical outcomes after implantation of a sutureless aortic bioprosthesis with concomitant mitral valve surgery: the SURE-AVR registry

    Get PDF
    Background: Early treatment of aortic valve stenosis is recommended in eligible symptomatic patients with severe aortic valve stenosis who would otherwise have a poor prognosis. The sutureless aortic valve bioprosthesis offers an alternative to standard aortic valve replacement with a sutured valve, but limited data are available in patients who have undergone multiple valve procedures involving the new, sutureless technology. We sought to investigate outcomes in high operative risk patients with previous or concomitant valve surgery who were implanted with a sutureless valve. Methods: SURE-AVR is an ongoing, prospective, multinational registry of patients undergoing aortic valve replacement. In-hospital and post-discharge outcomes up to 5 years were collected. Results: The study population comprised 78 patients (mean \ub1 SD: age 73.6 \ub1 7.6 years, logistic EuroSCORE 18.0 \ub1 17.5) enrolled at 13 sites who presented for concomitant or previous mitral valve repair (n\ua0= 45) or replacement (n\ua0= 33), with or without additional concomitant procedures, and were implanted with a sutureless valve. Mean \ub1 SD overall aortic cross-clamp time was 109 \ub1 41 min and cardiopulmonary bypass time was 152 \ub1 49 min. Mean \ub1 SD aortic pressure gradients decreased from 37.6 \ub1 17.7 mmHg preoperatively to 13.0 \ub1 5.7 mmHg at hospital discharge, and peak aortic pressure gradient from 61.5 \ub1 28.7 to 23.4 \ub1 10.6 mmHg. Early events included 1 death, 1 transient ischaemic attack, and 1 bleed (all 1.3%); a permanent pacemaker implantation was required in 6 patients (7.7%), and 2 reoperations (not valve related) (2.6%) took place. Over a median follow-up of 55.5 months (Q1 13.4, Q3 68.6), 12 patients died (6 cardiovascular and 6 non-cardiovascular, both 2.1% per patient-year). Five-year survival was 81.3%. Late paravalvular leak occurred in 2 patients (0.7% per patient-year) and permanent pacemaker implantation was required in 3 patients (0.1% per patient-year). There was no apparent rise in mean or peak aortic pressure gradient over the study. Conclusions: These results suggest that the sutureless implant is a technically feasible procedure during mitral surgery and is associated with good clinical outcomes

    Human iPSC modeling of a familial form of atrial fibrillation reveals a gain of function of If and ICaL in patient-derived cardiomyocytes

    Get PDF
    AIMS: Atrial Fibrillation (AF) is the most common type of cardiac arrhythmias, whose incidence is likely to increase with the aging of the population. It is considered a progressive condition, frequently observed as a complication of other cardiovascular disorders. However, recent genetic studies revealed the presence of several mutations and variants linked to AF, findings that define AF as a multifactorial disease. Due to the complex genetics and paucity of models, molecular mechanisms underlying the initiation of AF are still poorly understood.Here we investigate the pathophysiological mechanisms of a familial form of AF, with particular attention to the identification of putative triggering cellular mechanisms, using patient's derived cardiomyocytes differentiated from induced pluripotent stem cells (iPSC). METHODS AND RESULTS: Here we report the clinical case of three siblings with untreatable persistent AF whose whole-exome sequence analysis revealed several mutated genes. To understand the pathophysiology of this multifactorial form of AF we generated three iPSC clones from two of these patients and differentiated these cells toward the cardiac lineage. Electrophysiological characterization of patient-derived cardiomyocytes (AF-CMs) revealed that they have higher beating rates compared to control (CTRL)-CMs. The analysis showed an increased contribution of the If and ICaL currents. No differences were observed in the repolarizing current IKr and in the sarcoplasmic reticulum calcium handling. Paced AF-CMs presented significantly prolonged action potentials and, under stressful conditions, generated both delayed afterdepolarizations of bigger amplitude and more ectopic beats than CTRL cells. CONCLUSIONS: Our results demonstrate that the common genetic background of the patients induces functional alterations of If and ICaL currents leading to a cardiac substrate more prone to develop arrhythmias under demanding conditions. To our knowledge this is the first report that, using patient-derived CMs differentiated from iPSC, suggests a plausible cellular mechanism underlying this complex familial form of AF

    withdrawn 2017 hrs ehra ecas aphrs solaece expert consensus statement on catheter and surgical ablation of atrial fibrillation

    Get PDF
    n/

    THORACIC AORTA ANEURYSM

    No full text
    DESCRIZIONE DELLE CARATTERISTICHE PATOLOGICHE E CLINICHE NEI PAZIENTI PORTATORI DI ANEURISMA DELL'AORTA TORACIC

    Y grafting for coronary artery bypass: is it as good as single grafting?

    No full text
    To be printed in 200

    Endoscopic harvesting of the left internal mammary artery.

    No full text
    Minimally invasive coronary artery bypass grafting via left anterior small thoracotomy is routinely performed on patients with single coronary artery disease, but recently has been expanded to a larger population as a part of a hybrid treatment in multivessel coronary artery disease. While the methods of internal mammary artery harvesting used in these operations can be different, the endoscopic method is more advantageous than operations performed by direct vision, and thus should be used as a technique of choice. In this article, we present detailed description of endoscopic mammary artery harvesting focusing on anatomical and technical aspects
    corecore