9 research outputs found

    An integrated system for genetic analysis

    Get PDF
    BACKGROUND: Large-scale genetic mapping projects require data management systems that can handle complex phenotypes and detect and correct high-throughput genotyping errors, yet are easy to use. DESCRIPTION: We have developed an Integrated Genotyping System (IGS) to meet this need. IGS securely stores, edits and analyses genotype and phenotype data. It stores information about DNA samples, plates, primers, markers and genotypes generated by a genotyping laboratory. Data are structured so that statistical genetic analysis of both case-control and pedigree data is straightforward. CONCLUSION: IGS can model complex phenotypes and contain genotypes from whole genome association studies. The database makes it possible to integrate genetic analysis with data curation. The IGS web site contains further information

    NOX1 loss-of-function genetic variants in patients with inflammatory bowel disease.

    Get PDF
    Genetic defects that affect intestinal epithelial barrier function can present with very early-onset inflammatory bowel disease (VEOIBD). Using whole-genome sequencing, a novel hemizygous defect in NOX1 encoding NAPDH oxidase 1 was identified in a patient with ulcerative colitis-like VEOIBD. Exome screening of 1,878 pediatric patients identified further seven male inflammatory bowel disease (IBD) patients with rare NOX1 mutations. Loss-of-function was validated in p.N122H and p.T497A, and to a lesser degree in p.Y470H, p.R287Q, p.I67M, p.Q293R as well as the previously described p.P330S, and the common NOX1 SNP p.D360N (rs34688635) variant. The missense mutation p.N122H abrogated reactive oxygen species (ROS) production in cell lines, ex vivo colonic explants, and patient-derived colonic organoid cultures. Within colonic crypts, NOX1 constitutively generates a high level of ROS in the crypt lumen. Analysis of 9,513 controls and 11,140 IBD patients of non-Jewish European ancestry did not reveal an association between p.D360N and IBD. Our data suggest that loss-of-function variants in NOX1 do not cause a Mendelian disorder of high penetrance but are a context-specific modifier. Our results implicate that variants in NOX1 change brush border ROS within colonic crypts at the interface between the epithelium and luminal microbes

    Linkage Analysis of Extremely Discordant and Concordant Sibling Pairs Identifies Quantitative-Trait Loci That Influence Variation in the Human Personality Trait Neuroticism

    Get PDF
    Several theoretical studies have suggested that large samples of randomly ascertained siblings can be used to ascertain phenotypically extreme individuals and thereby increase power to detect genetic linkage in complex traits. Here, we report a genetic linkage scan using extremely discordant and concordant sibling pairs, selected from 34,580 sibling pairs in the southwest of England who completed a personality questionnaire. We performed a genomewide scan for quantitative-trait loci (QTLs) that influence variation in the personality trait of neuroticism, or emotional stability, and we established genomewide empirical significance thresholds by simulation. The maximum pointwise P values, expressed as the negative logarithm (base 10), were found on 1q (3.95), 4q (3.84), 7p (3.90), 12q (4.74), and 13q (3.81). These five loci met or exceeded the 5% genomewide significance threshold of 3.8 (negative logarithm of the P value). QTLs on chromosomes 1, 12, and 13 are likely to be female specific. One locus, on chromosome 1, is syntenic with that reported from QTL mapping of rodent emotionality, an animal model of neuroticism, suggesting that some animal and human QTLs influencing emotional stability may be homologous

    Factors influencing success of clinical genome sequencing across a broad spectrum of disorders

    No full text
    To assess factors influencing the success of whole-genome sequencing for mainstream clinical diagnosis, we sequenced 217 individuals from 156 independent cases or families across a broad spectrum of disorders in whom previous screening had identified no pathogenic variants. We quantified the number of candidate variants identified using different strategies for variant calling, filtering, annotation and prioritization. We found that jointly calling variants across samples, filtering against both local and external databases, deploying multiple annotation tools and using familial transmission above biological plausibility contributed to accuracy. Overall, we identified disease-causing variants in 21% of cases, with the proportion increasing to 34% (23/68) for mendelian disorders and 57% (8/14) in family trios. We also discovered 32 potentially clinically actionable variants in 18 genes unrelated to the referral disorder, although only 4 were ultimately considered reportable. Our results demonstrate the value of genome sequencing for routine clinical diagnosis but also highlight many outstanding challenges

    Notes and References

    No full text

    Factors influencing success of clinical genome sequencing across a broad spectrum of disorders

    No full text
    corecore