720 research outputs found

    A description of the neutralino observables in terms of projectors

    Get PDF
    Applying Jarlskog's treatment of the CKM matrix, to the neutralino mass matrix in MSSM for real soft gaugino SUSY breaking and μ\mu-parameters, we construct explicit analytical expressions for the four projectors which acting on any neutralino state project out the mass eigenstates. Analytical expressions for the neutralino mass eigenvalues in terms of the various SUSY parameters, are also given. It is shown that these projectors and mass eigenvalues are sufficient to describe any physical observable involving neutralinos, to any order of perturbation theory. As an example, the ee+χ~i0χ~j0e^-e^+ \to \tilde \chi^0_i \tilde \chi^0_j cross section at tree level is given in terms of these projectors. The expected magnitude of their various matrix elements in plausible SUSY scenarios is also discussed.Comment: 14 pages, no figures. Version to appear in Phys. Rev. D. e-mail: [email protected]

    Statistical mechanics of RNA folding: importance of alphabet size

    Full text link
    We construct a minimalist model of RNA secondary-structure formation and use it to study the mapping from sequence to structure. There are strong, qualitative differences between two-letter and four or six-letter alphabets. With only two kinds of bases, there are many alternate folding configurations, yielding thermodynamically stable ground-states only for a small set of structures of high designability, i.e., total number of associated sequences. In contrast, sequences made from four bases, as found in nature, or six bases have far fewer competing folding configurations, resulting in a much greater average stability of the ground state.Comment: 7 figures; uses revtex

    Gyration radius of a circular polymer under a topological constraint with excluded volume

    Full text link
    It is nontrivial whether the average size of a ring polymer should become smaller or larger under a topological constraint. Making use of some knot invariants, we evaluate numerically the mean square radius of gyration for ring polymers having a fixed knot type, where the ring polymers are given by self-avoiding polygons consisting of freely-jointed hard cylinders. We obtain plots of the gyration radius versus the number of polygonal nodes for the trivial, trefoil and figure-eight knots. We discuss possible asymptotic behaviors of the gyration radius under the topological constraint. In the asymptotic limit, the size of a ring polymer with a given knot is larger than that of no topological constraint when the polymer is thin, and the effective expansion becomes weak when the polymer is thick enough.Comment: 12pages,3figure

    Extension to order β23\beta^{23} of the high-temperature expansions for the spin-1/2 Ising model on the simple-cubic and the body-centered-cubic lattices

    Get PDF
    Using a renormalized linked-cluster-expansion method, we have extended to order β23\beta^{23} the high-temperature series for the susceptibility χ\chi and the second-moment correlation length ξ\xi of the spin-1/2 Ising models on the sc and the bcc lattices. A study of these expansions yields updated direct estimates of universal parameters, such as exponents and amplitude ratios, which characterize the critical behavior of χ\chi and ξ\xi. Our best estimates for the inverse critical temperatures are βcsc=0.221654(1)\beta^{sc}_c=0.221654(1) and βcbcc=0.1573725(6)\beta^{bcc}_c=0.1573725(6). For the susceptibility exponent we get γ=1.2375(6)\gamma=1.2375(6) and for the correlation length exponent we get ν=0.6302(4)\nu=0.6302(4). The ratio of the critical amplitudes of χ\chi above and below the critical temperature is estimated to be C+/C=4.762(8)C_+/C_-=4.762(8). The analogous ratio for ξ\xi is estimated to be f+/f=1.963(8)f_+/f_-=1.963(8). For the correction-to-scaling amplitude ratio we obtain aξ+/aχ+=0.87(6)a^+_{\xi}/a^+_{\chi}=0.87(6).Comment: Misprints corrected, 8 pages, latex, no figure

    Deceleration and trapping of heavy diatomic molecules using a ring-decelerator

    Full text link
    We present an analysis of the deceleration and trapping of heavy diatomic molecules in low-field seeking states by a moving electric potential. This moving potential is created by a 'ring-decelerator', which consists of a series of ring-shaped electrodes to which oscillating high voltages are applied. Particle trajectory simulations have been used to analyze the deceleration and trapping efficiency for a group of molecules that is of special interest for precision measurements of fundamental discrete symmetries. For the typical case of the SrF molecule in the (N,M) = (2, 0) state, the ring-decelerator is shown to outperform traditional and alternate-gradient Stark decelerators by at least an order of magnitude. If further cooled by a stage of laser cooling, the decelerated molecules allow for a sensitivity gain in a parity violation measurement, compared to a cryogenic molecular beam experiment, of almost two orders of magnitude

    Impact of the COVID‐19 pandemic on the productivity and career prospects of musculoskeletal researchers

    Get PDF
    Academic researchers faced a multitude of challenges posed by the COVID-19 pandemic, including widespread shelter-in-place orders, workplace closures, and cessation of in-person meetings and laboratory activities. The extent to which these challenges impacted musculoskeletal researchers, specifically, is unknown. We developed an anonymous web-based survey to determine the pandemic's impact on research productivity and career prospects among musculoskeletal research trainees and faculty. There were 116 musculoskeletal (MSK) researchers with varying demographic backgrounds who completed the survey. Of respondents, 48.3% (n = 56) believed that musculoskeletal funding opportunities decreased because of COVID-19, with faculty members more likely to hold this belief compared to nonfaculty researchers (p = 0.008). Amongst MSK researchers, 88.8% (n = 103) reported research activity was limited by COVID-19, and 92.2% (n = 107) of researchers reported their research was not able to be refocused on COVID-19-related topics, with basic science researchers less likely to be able to refocus their research compared to clinical researchers (p = 0.030). Additionally, 47.4% (n = 55) reported a decrease in manuscript submissions since the onset of the pandemic. Amongst 51 trainee researchers, 62.8% (n = 32) reported a decrease in job satisfaction directly attributable to the COVID-19 pandemic. In summary, study findings indicated that MSK researchers struggled to overcome challenges imposed by the pandemic, reporting declines in funding opportunities, research productivity, and manuscript submission. Trainee researchers experienced significant disruptions to critical research activities and worsening job satisfaction. Our findings motivate future efforts to support trainees in developing their careers and target the recovery of MSK research from the pandemic stall

    Adsorption of mono- and multivalent cat- and anions on DNA molecules

    Get PDF
    Adsorption of monovalent and multivalent cat- and anions on a deoxyribose nucleic acid (DNA) molecule from a salt solution is investigated by computer simulation. The ions are modelled as charged hard spheres, the DNA molecule as a point charge pattern following the double-helical phosphate strands. The geometrical shape of the DNA molecules is modelled on different levels ranging from a simple cylindrical shape to structured models which include the major and minor grooves between the phosphate strands. The densities of the ions adsorbed on the phosphate strands, in the major and in the minor grooves are calculated. First, we find that the adsorption pattern on the DNA surface depends strongly on its geometrical shape: counterions adsorb preferentially along the phosphate strands for a cylindrical model shape, but in the minor groove for a geometrically structured model. Second, we find that an addition of monovalent salt ions results in an increase of the charge density in the minor groove while the total charge density of ions adsorbed in the major groove stays unchanged. The adsorbed ion densities are highly structured along the minor groove while they are almost smeared along the major groove. Furthermore, for a fixed amount of added salt, the major groove cationic charge is independent on the counterion valency. For increasing salt concentration the major groove is neutralized while the total charge adsorbed in the minor groove is constant. DNA overcharging is detected for multivalent salt. Simulations for a larger ion radii, which mimic the effect of the ion hydration, indicate an increased adsorbtion of cations in the major groove.Comment: 34 pages with 14 figure

    Controversies in spine research: organ culture versus in vivo models for studies of the intervertebral disc

    Get PDF
    Intervertebral disc degeneration is a common cause of low back pain, the leading cause of disability worldwide. Appropriate preclinical models for intervertebral disc research are essential to achieving a better understanding of underlying pathophysiology and for the development, evaluation, and translation of more effective treatments. To this end, in vivo animal and ex vivo organ culture models are both widely used by spine researchers; however, the relative strengths and weaknesses of these two approaches are a source of ongoing controversy. In this article, members from the Spine and Preclinical Models Sections of the Orthopedic Research Society, including experts in both basic and translational spine research, present contrasting arguments in support of in vivo animal models versus ex vivo organ culture models for studies of the disc, supported by a comprehensive review of the relevant literature. The objective is to provide a deeper understanding of the respective advantages and limitations of these approaches, and advance the field toward a consensus with respect to appropriate model selection and implementation. We conclude that complementary use of several model types and leveraging the unique advantages of each is likely to result in the highest impact research in most instances

    Measurement of the Bottom-Strange Meson Mixing Phase in the Full CDF Data Set

    Get PDF
    We report a measurement of the bottom-strange meson mixing phase \beta_s using the time evolution of B0_s -> J/\psi (->\mu+\mu-) \phi (-> K+ K-) decays in which the quark-flavor content of the bottom-strange meson is identified at production. This measurement uses the full data set of proton-antiproton collisions at sqrt(s)= 1.96 TeV collected by the Collider Detector experiment at the Fermilab Tevatron, corresponding to 9.6 fb-1 of integrated luminosity. We report confidence regions in the two-dimensional space of \beta_s and the B0_s decay-width difference \Delta\Gamma_s, and measure \beta_s in [-\pi/2, -1.51] U [-0.06, 0.30] U [1.26, \pi/2] at the 68% confidence level, in agreement with the standard model expectation. Assuming the standard model value of \beta_s, we also determine \Delta\Gamma_s = 0.068 +- 0.026 (stat) +- 0.009 (syst) ps-1 and the mean B0_s lifetime, \tau_s = 1.528 +- 0.019 (stat) +- 0.009 (syst) ps, which are consistent and competitive with determinations by other experiments.Comment: 8 pages, 2 figures, Phys. Rev. Lett 109, 171802 (2012
    corecore