9 research outputs found

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    Effect of IVL745, a VLA-4 antagonist, on allergen-induced bronchoconstriction in patients with asthma

    No full text
    Background: Very late antigen (VLA-4) antagonists have been proposed as potential therapies for diseases in which cell recruitment and accumulation are causative. Asthma, which is characterized by airway inflammation involving the accumulation of eosinophils and mononuclear cells, is one such disease.Objective: We sought to assess the effect of IVL745, a VLA-4 antagonist, on the early and late asthmatic response (LAR) and on markers of airway inflammation after allergen inhalation.Methods: The study was of a placebo-controlled, double-blind, randomized, 2-way crossover design. Sixteen subjects with mild-to-moderate asthma controlled with short-acting ?2-agonists only and with a LAR to inhaled allergen participated in the study. At one treatment period they took 20 mg of IVL745 and one treatment period placebo. Both treatments were taken twice daily for 7 days, with a single dose on day 8. Treatments were separated by a washout period of at least 2 weeks. On day 7 of each treatment period, sputum was induced and collected, and exhaled nitric oxide (NO) was measured. On day 8, an inhaled bolus allergen challenge was performed, and blood was taken for pharmacokinetics. On day 9, exhaled NO was measured, and a methacholine challenge was done. On day 10, sputum was induced and collected. Adverse events, peak expiratory flow (PEF), use of short-acting ?2-agonists, and asthma symptoms were recorded daily throughout the study.Results: There was no statistically significant difference between IVL745 and placebo in the effect on the LAR after allergen challenge, as measured by the area under the curve of the percentage change in FEV1 from the prechallenge baseline (mean [SEM], ?81.99 [18.80] after IVL745 and ?72.58 [21.29] after placebo; 95% CI of difference, ?36 to 16.8; P = .46) or by the maximum percentage change from the prechallenge baseline (mean [SEM], ?23.44 [4.73] after IVL745 and ?21.30 [5.17] after placebo; 95% CI of difference, ?11 to 6.29; P = .60). There was a statistically significant decrease in the percentage of eosinophils in sputum on day 7 of treatment with IVL745 (mean [SEM], 7.32 [1.46]) compared with placebo (mean [SEM], 15.00 [1.92]; 95% CI of difference, ?13 to ?1.2; P = .02). There was no statistically significant difference between IVL745 and placebo with respect to the early asthmatic response, methacholine hyperresponsiveness, exhaled NO, postallergen sputum, symptoms, inhaled ?2-agonist use, or PEF.Conclusion: In patients with mild-to-moderate atopic asthma, IVL745 did not affect the early and late response to inhaled allergen or markers of airway inflammation, except for a modest reduction in sputum eosinophils

    Single Ascending Dose Study of a Short Interfering RNA Targeting Lipoprotein(a) Production in Individuals with Elevated Plasma Lipoprotein(a) Levels

    No full text
    Importance: Lipoprotein(a) (Lp[a]) is an important risk factor for atherothrombotic cardiovascular disease and aortic stenosis, for which there are no treatments approved by regulatory authorities. Objectives: To assess adverse events and tolerability of a short interfering RNA (siRNA) designed to reduce hepatic production of apolipoprotein(a) and to assess associated changes in plasma concentrations of Lp(a) at different doses. Design, Setting, and Participants: A single ascending dose study of SLN360, an siRNA targeting apolipoprotein(a) synthesis conducted at 5 clinical research unit sites located in the US, United Kingdom, and Australia. The study enrolled adults with Lp(a) plasma concentrations of 150 nmol/L or greater at screening and no known clinically overt cardiovascular disease. Participants were enrolled between November 18, 2020, and July 21, 2021, with last follow-up on December 29, 2021. Interventions: Participants were randomized to receive placebo (n = 8) or single doses of SLN360 at 30 mg (n = 6), 100 mg (n = 6), 300 mg (n = 6), or 600 mg (n = 6), administered subcutaneously. Main Outcomes and Measures: The primary outcome was evaluation of safety and tolerability. Secondary outcomes included change in plasma concentrations of Lp(a) to a maximum follow-up of 150 days. Results: Among 32 participants who were randomized and received the study intervention (mean age, 50 [SD, 13.5] years; 17 women [53%]), 32 (100%) completed the trial. One participant experienced 2 serious adverse event episodes: admission to the hospital for headache following SARS-CoV-2 vaccination and later for complications of cholecystitis, both of which were judged to be unrelated to study drug. Median baseline Lp(a) concentrations were as follows: placebo, 238 (IQR, 203-308) nmol/L; 30-mg SLN360, 171 (IQR, 142-219) nmol/L; 100-mg SLN360, 217 (IQR, 202-274) nmol/L; 300-mg SLN360, 285 (IQR, 195-338) nmol/L; and 600-mg SLN360, 231 (IQR, 179-276) nmol/L. Maximal median changes in Lp(a) were -20 (IQR, -61 to 3) nmol/L, -89 (IQR, -119 to -61) nmol/L, -185 (IQR, -226 to -163) nmol/L, -268 (IQR, -292 to -189) nmol/L, and -227 (IQR, -270 to -174) nmol/L, with maximal median percentage changes of -10% (IQR, -16% to 1%), -46% (IQR, -64% to -40%), -86% (IQR, -92% to -82%), -96% (IQR, -98% to -89%), and -98% (IQR, -98% to -97%), for the placebo group and the 30-mg, 100-mg, 300-mg, and 600-mg SLN360 groups, respectively. The duration of Lp(a) lowering was dose dependent, persisting for at least 150 days after administration. Conclusions and Relevance: In this phase 1 study of 32 participants with elevated Lp(a) levels and no known cardiovascular disease, the siRNA SLN360 was well tolerated, and a dose-dependent lowering of plasma Lp(a) concentrations was observed. The findings support further study to determine the safety and efficacy of this siRNA. Trial Registration: ClinicalTrials.gov Identifier: NCT04606602; EudraCT Identifier: 2020-002471-35

    References

    No full text

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    No full text
    48 pages, 29 figures, submitted for publication in Experimental AstronomyThe Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. It is expected that thanks to the studies conducted so far on X-IFU, along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained (abridged)

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    48 pages, 29 figures, submitted for publication in Experimental AstronomyThe Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. It is expected that thanks to the studies conducted so far on X-IFU, along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained (abridged)

    Ecology of tetranychid mites and their natural enemies: A review: III. Biology, ecology, and pest status, and host-plant relations of tetranychids

    No full text
    corecore