140 research outputs found

    Physiological consequences of CPAP therapy withdrawal in patients with obstructive sleep apnoea-an opportunity for an efficient experimental model

    Full text link
    Randomised controlled trials (RCTs) of continuous positive airway pressure (CPAP) in obstructive sleep apnoea (OSA) are time consuming, and their findings often inconclusive or limited due to suboptimal CPAP adherence in CPAP-naïve patients with OSA. Short-term CPAP withdrawal in patients with prior optimal CPAP adherence results in recurrence of OSA and its consequences. Thus, this experimental model serves as an efficient tool to investigate both the consequences of untreated OSA, and potential treatment alternatives to CPAP. The CPAP withdrawal protocol has been thoroughly validated, and applied in several RCTs focusing on cardiovascular and metabolic consequences of untreated OSA, as well as the assessment of treatment alternatives to CPAP

    Elevated levels of Endothelial cell-derived microparticles following short-term withdrawal of continuous positive airway pressure in patients with obstructive sleep apnea: Data from a randomized controlled trial

    Full text link
    Background: Obstructive sleep apnea has been associated with impaired endothelial function; however, the mechanisms underlying this association are not completely understood. Cell-derived microparticles may provide a link between obstructive sleep apnea and endothelial dysfunction. Objectives: This randomized controlled trial aimed to examine the effect of a 2-week withdrawal of continuous positive airway pressure (CPAP) therapy on levels of circulating microparticles. Methods: Forty-one obstructive sleep apnea patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continuing therapeutic CPAP, for 2 weeks. Polysomnography was performed and circulating levels of microparticles were analyzed by flow cytometry at baseline and 2 weeks. Results: CPAP withdrawal led to a recurrence of obstructive sleep apnea. Levels of CD62E+ endothelium-derived microparticles increased significantly in the CPAP withdrawal group compared to the continuing therapeutic CPAP group (median difference in change +32.4 per µl; 95% CI +7.3 to +64.1 per µl, p = 0.010). CPAP withdrawal was not associated with a statistically significant increase in granulocyte, leukocyte, and platelet-derived microparticles when compared with therapeutic CPAP. Conclusions: Short-term withdrawal of CPAP therapy leads to a significant increase in endothelium-derived microparticles, suggesting that microparticle formation may be causally linked to obstructive sleep apnea and may promote endothelial activation

    Measurement of the Z/gamma* + b-jet cross section in pp collisions at 7 TeV

    Get PDF
    The production of b jets in association with a Z/gamma* boson is studied using proton-proton collisions delivered by the LHC at a centre-of-mass energy of 7 TeV and recorded by the CMS detector. The inclusive cross section for Z/gamma* + b-jet production is measured in a sample corresponding to an integrated luminosity of 2.2 inverse femtobarns. The Z/gamma* + b-jet cross section with Z/gamma* to ll (where ll = ee or mu mu) for events with the invariant mass 60 < M(ll) < 120 GeV, at least one b jet at the hadron level with pT > 25 GeV and abs(eta) < 2.1, and a separation between the leptons and the jets of Delta R > 0.5 is found to be 5.84 +/- 0.08 (stat.) +/- 0.72 (syst.) +(0.25)/-(0.55) (theory) pb. The kinematic properties of the events are also studied and found to be in agreement with the predictions made by the MadGraph event generator with the parton shower and the hadronisation performed by PYTHIA.Comment: Submitted to the Journal of High Energy Physic

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    SmokeHaz: systematic reviews and meta-analyses of the effects of smoking on respiratory health

    Get PDF
    Background: Smoking tobacco increases the risk of respiratory disease in adults and children, but communicating the magnitude of these effects in a scientific manner that is accessible and usable by public and policymakers presents a challenge. We have therefore summarised scientific data on the impact of smoking on respiratory diseases to provide the content for a unique resource, SmokeHaz. Methods: We conducted systematic reviews and meta-analyses of longitudinal studies (published to 2013) identified from electronic databases, grey literature, and experts. Random effect meta-analyses were used to pool the findings. Results: We included 216 papers. Among adult smokers, we confirmed substantially increased risks of lung cancer (Risk Ratio (RR) 10.92, 95% CI 8.28-14.40; 34 studies), COPD (RR 4.01, 95% CI 3.18-5.05; 22 studies) and asthma (RR 1.61, 95% CI 1.07-2.42; 8 studies). Exposure to passive smoke significantly increased the risk of lung cancer in adult non-smokers; and increased the risks of asthma, wheeze, lower respiratory infections, and reduced lung function in children. Smoking significantly increased the risk of sleep apnoea, and asthma exacerbations in adult and pregnant populations; and active and passive smoking increased the risk of tuberculosis. Conclusions: These findings have been translated into easily digestible content and published on the SmokeHaz website (www.smokehaz.eu)

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Measurements of top-quark pair differential cross-sections in the eμe\mu channel in pppp collisions at s=13\sqrt{s} = 13 TeV using the ATLAS detector

    Get PDF
    corecore