2,578 research outputs found

    Convalescent plasma treatment for patients of 80 years and older with COVID-19 pneumonia

    Get PDF
    Background: Older patients, frequently with multiple comorbidities, have a high mortality from COVID-19 infection. Convalescent plasma (CP) is a therapeutic option for these patients. Our objective is to retrospectively evaluate the efficacy and adverse events of CP treatment in this population group. Methods: Forty one patients over 80 years old with COVID-19 pneumonia received CP added to standard treatment, 51.2% with high anti-SARS-CoV-2 IgG titers and 48.8% with low titers. Median time between the onset of symptoms and the infusion of plasma was 7 days (IQR 4-10). A similar group of 82 patients who received only standard treatment, during a period in which CP was not available, were selected as a control group. Results: In-hospital mortality was 26.8% for controls and 14.6% for CP patients (P = 0.131) and ICU admission was 8.5% for controls and 4.9% for CP patients (P = 0.467). Mortality tended to be lower in the high-titer group (9.5%) than in the low-titer group (20%), and in patients transfused within the first 7 days of symptom onset (10%) than in patients transfused later (19.1%), although the differences were not statistically significant (P = 0.307 and P = 0.355 respectively). There was no difference in the length of hospitalization. No significant adverse events were associated with CP treatment. Conclusions: Convalescent plasma treatment in patients over 80 years old with COVID-19 pneumonia was well tolerated but did not present a statistically significant difference in hospital mortality, ICU admission, or length of hospitalization. The results should be interpreted with caution as only half the patients received high-titer CP and the small number of patients included in the study limits the statistical power to detect significant differences

    Case-Control Analysis of the Impact of Anemia on Quality of Life in Patients with Cancer: A Qca Study Analysis

    Get PDF
    The impact of anemia on the quality of life (QoL) in cancer patients has been studied previously; however, the cut-off point used to define anemia differed among studies, thus providing inconsistent results. Therefore, we analysed the clinical impact of anemia on QoL using the same cut-off point for hemoglobin level to define anemia as that used in ESMO clinical practice guidelines. This post-hoc analysis aimed to determine the impact of anemia on QoL in cancer patients through the European Organization for Research and Treatment of Cancer Quality of life questionnaire version 3.0 (EORTC QLQ-C30) and Euro QoL 5-dimension 3-level (EQ-5D-3L) questionnaire. We found that cancer patients with anemia had significantly worse QoL in clinical terms. In addition, anemic patients had more pronounced symptoms than those in non-anemic patients. Anemia is a common condition in cancer patients and is associated with a wide variety of symptoms that impair quality of life (QoL). However, exactly how anemia affects QoL in cancer patients is unclear because of the inconsistencies in its definition in previous reports. We aimed to examine the clinical impact of anemia on the QoL of cancer patients using specific questionnaires. We performed a post-hoc analysis of a multicenter, prospective, case-control study. We included patients with cancer with (cases) or without (controls) anemia. Participants completed the European Organization for Research and Treatment of Cancer Quality of Life questionnaire version 3.0 (EORTC QLQ-C30) and Euro QoL 5-dimension 3-level (EQ-5D-3L) questionnaire. Statistically significant and clinically relevant differences in the global health status were examined. From 2015 to 2018, 365 patients were included (90 cases and 275 controls). We found minimally important differences in global health status according to the EORTC QLQ-C30 questionnaire (case vs. controls: 45.6 vs. 58%, respectively; mean difference: -12.4, p < 0.001). Regarding symptoms, cancer patients with anemia had more pronounced symptoms in six out of nine scales in comparison with those without anemia. In conclusion, cancer patients with anemia had a worse QoL both clinically and statistically

    Measurement of the Lifetime Difference Between B_s Mass Eigenstates

    Get PDF
    We present measurements of the lifetimes and polarization amplitudes for B_s --> J/psi phi and B_d --> J/psi K*0 decays. Lifetimes of the heavy (H) and light (L) mass eigenstates in the B_s system are separately measured for the first time by determining the relative contributions of amplitudes with definite CP as a function of the decay time. Using 203 +/- 15 B_s decays, we obtain tau_L = (1.05 +{0.16}/-{0.13} +/- 0.02) ps and tau_H = (2.07 +{0.58}/-{0.46} +/- 0.03) ps. Expressed in terms of the difference DeltaGamma_s and average Gamma_s, of the decay rates of the two eigenstates, the results are DeltaGamma_s/Gamma_s = (65 +{25}/-{33} +/- 1)%, and DeltaGamma_s = (0.47 +{0.19}/-{0.24} +/- 0.01) inverse ps.Comment: 8 pages, 3 figures, 2 tables; as published in Physical Review Letters on 16 March 2005; revisions are for length and typesetting only, no changes in results or conclusion

    Allergic Rhinitis and its Impact on Asthma (ARIA) Phase 4 (2018) : Change management in allergic rhinitis and asthma multimorbidity using mobile technology

    Get PDF
    Allergic Rhinitis and its Impact on Asthma (ARIA) has evolved from a guideline by using the best approach to integrated care pathways using mobile technology in patients with allergic rhinitis (AR) and asthma multimorbidity. The proposed next phase of ARIA is change management, with the aim of providing an active and healthy life to patients with rhinitis and to those with asthma multimorbidity across the lifecycle irrespective of their sex or socioeconomic status to reduce health and social inequities incurred by the disease. ARIA has followed the 8-step model of Kotter to assess and implement the effect of rhinitis on asthma multimorbidity and to propose multimorbid guidelines. A second change management strategy is proposed by ARIA Phase 4 to increase self-medication and shared decision making in rhinitis and asthma multimorbidity. An innovation of ARIA has been the development and validation of information technology evidence-based tools (Mobile Airways Sentinel Network [MASK]) that can inform patient decisions on the basis of a self-care plan proposed by the health care professional.Peer reviewe

    Adherence to treatment in allergic rhinitis using mobile technology. The MASK Study

    Get PDF
    Background: Mobile technology may help to better understand the adherence to treatment. MASK-rhinitis (Mobile Airways Sentinel NetworK for allergic rhinitis) is a patient-centred ICT system. A mobile phone app (the Allergy Diary) central to MASK is available in 22 countries. Objectives: To assess the adherence to treatment in allergic rhinitis patients using the Allergy Diary App. Methods: An observational cross-sectional study was carried out on all users who filled in the Allergy Diary from 1 January 2016 to 1 August 2017. Secondary adherence was assessed by using the modified Medication Possession Ratio (MPR) and the Proportion of days covered (PDC) approach. Results: A total of 12143 users were registered. A total of 6949 users reported at least one VAS data recording. Among them, 1887 users reported >= 7 VAS data. About 1195 subjects were included in the analysis of adherence. One hundred and thirty-six (11.28%) users were adherent (MPR >= 70% and PDC = 70% and PDC = 1.50) and 176 (14.60%) were switchers. On the other hand, 832 (69.05%) users were non-adherent to medications (MPR Conclusion and clinical relevance: Adherence to treatment is low. The relative efficacy of continuous vs on-demand treatment for allergic rhinitis symptoms is still a matter of debate. This study shows an approach for measuring retrospective adherence based on a mobile app. This also represents a novel approach for analysing medication-taking behaviour in a real-world setting.Peer reviewe

    Measurement of the W-Pair Production Cross Section and W-Decay Branching Fractions in e+ee^{+}e^{-} Interactions at s\sqrt{s}= 189 GeV

    Get PDF
    The data collected by the L3 experiment at LEP at a centre-of-mass energy of 188.6 GeV188.6~\rm{Ge\kern -0.1em V} are used to measure the W-pair production cross section and the W-boson decay branching fractions. These data correspond to an integrated luminosity of 176.8~pb1^{-1}. The total cross section for W-pair production, combining all final states, is measured to be σWW=16.24±0.37 (stat.)±0.22 (syst.)\sigma_{\rm{WW}}= 16.24 \pm 0.37~(stat.) \pm 0.22~(syst.)~pb. Including our data collected at lower centre-of-mass energies, the hadronic branching fraction of the W-boson is determined to be B(Wqq)=[68.20±0.68 (stat.)±0.33 (syst.)] % B(\rm{W} \rightarrow \rm{qq})= \left[ 68.20 \pm 0.68~(stat.) \pm 0.33~(syst.)\right]~\%. The results agree with the Standard Model predictions.The data collected by the L3 experiment at LEP at a centre-of-mass energy of 188.6 GeV are used to measure the W-pair production cross section and the W-boson decay branching fractions. These data correspond to an integrated luminosity of 176.8pb^-1. The total cross section for W-pair production, combining all final states, is measured to be sigma_WW = 16.24 +/- 0.37(stat.) +/- 0.22(syst.) pb. Including our data collected at lower centre-of-mass energies, the hadronic branching fraction of the W-boson is determined to be B(W ->qq) = [68.20 +/- 0.68 (stat.) +/- 0.33 (syst.) ] %. The results agree with the Standard Model predictions.The data collected by the L3 experiment at LEP at a centre-of-mass energy of 188.6 GeV are used to measure the W-pair production cross section and the W-boson decay branching fractions. These data correspond to an integrated luminosity of 176.8 pb −1 . The total cross section for W-pair production, combining all final states, is measured to be σ WW =16.24±0.37 (stat.)±0.22 (syst.) pb. Including our data collected at lower centre-of-mass energies, the hadronic branching fraction of the W-boson is determined to be B (W→qq)=[68.20±0.68 (stat.)±0.33 (syst.)]%. The results agree with the Standard Model predictions

    Correlation between work impairment, scores of rhinitis severity and asthma using the MASK-air (R) App

    Get PDF
    Background In allergic rhinitis, a relevant outcome providing information on the effectiveness of interventions is needed. In MASK-air (Mobile Airways Sentinel Network), a visual analogue scale (VAS) for work is used as a relevant outcome. This study aimed to assess the performance of the work VAS work by comparing VAS work with other VAS measurements and symptom-medication scores obtained concurrently. Methods All consecutive MASK-air users in 23 countries from 1 June 2016 to 31 October 2018 were included (14 189 users; 205 904 days). Geolocalized users self-assessed daily symptom control using the touchscreen functionality on their smart phone to click on VAS scores (ranging from 0 to 100) for overall symptoms (global), nose, eyes, asthma and work. Two symptom-medication scores were used: the modified EAACI CSMS score and the MASK control score for rhinitis. To assess data quality, the intra-individual response variability (IRV) index was calculated. Results A strong correlation was observed between VAS work and other VAS. The highest levels for correlation with VAS work and variance explained in VAS work were found with VAS global, followed by VAS nose, eye and asthma. In comparison with VAS global, the mCSMS and MASK control score showed a lower correlation with VAS work. Results are unlikely to be explained by a low quality of data arising from repeated VAS measures. Conclusions VAS work correlates with other outcomes (VAS global, nose, eye and asthma) but less well with a symptom-medication score. VAS work should be considered as a potentially useful AR outcome in intervention studies.Peer reviewe

    A communal catalogue reveals Earth's multiscale microbial diversity

    Get PDF
    Our growing awareness of the microbial world's importance and diversity contrasts starkly with our limited understanding of its fundamental structure. Despite recent advances in DNA sequencing, a lack of standardized protocols and common analytical frameworks impedes comparisons among studies, hindering the development of global inferences about microbial life on Earth. Here we present a meta-analysis of microbial community samples collected by hundreds of researchers for the Earth Microbiome Project. Coordinated protocols and new analytical methods, particularly the use of exact sequences instead of clustered operational taxonomic units, enable bacterial and archaeal ribosomal RNA gene sequences to be followed across multiple studies and allow us to explore patterns of diversity at an unprecedented scale. The result is both a reference database giving global context to DNA sequence data and a framework for incorporating data from future studies, fostering increasingly complete characterization of Earth's microbial diversity.Peer reviewe
    corecore