195 research outputs found

    A survey to explore the current use of injection therapy as part of a conservative treatment plan for degenerative meniscal lesions within UK based, injection trained physiotherapy members of the society of musculoskeletal medicine

    Get PDF
    Objectives: To explore the current use of injection therapy as part of a conservative treatment plan for degenerative meniscal lesions (DML) within UK based physiotherapy members of the Society of Musculoskeletal Medicine (SOMM) with injection training. Methods: An online survey was distributed via email to all UK based, SOMM physiotherapists who had trained and received their injection diploma through the SOMM (n = 203) with a response rate of 32% (n = 64). The data were analysed using descriptive statistics, contingency tables and the Fisher's exact test. A P value ≤0.05 was considered significant. Ethical clearance was gained through the SOMM and Middlesex University. Results: Of the respondents 98% (n = 62) of current UK based, injection trained SOMM physiotherapists utilize conservative treatment for DML of which 81% (n = 52) include injection therapy. Seventy-seven per cent (n = 49) who currently use injection therapy for DML administer a combination of 40 mg Depomedrone combined with local anaesthetic via a patellofemoral approach. Those not using injection therapy as part of their management of DML attributed this to local department restrictions and lack of evidence. Discussion: This research has helped further understand the use of injection therapy for DML and where it fits within a conservative treatment plan. The benefit from injection therapy reported by respondents is similar to previous research but could be influenced by injection exposure and potentially steroid choice. Overall a consensus is starting to appear regarding dosage, steroid, and administration; however, differences arise when comparing individual department guidelines to CSP and NICE guidelines

    Chlorophyll a reconstruction from in situ measurements: 2. Marked carbon uptake decrease in the last century

    Get PDF
    A chlorophyll a hindcast in the Madeira Basin from 1871 to 2008 was used to analyze the long-term variability in the oligotrophic, subtropical gyres in relation to the climate change of the last century. The deep chlorophyll maximum (DCM), as dominant pattern of the chlorophyll a field, showed a fast decrease in its strength in the 1940s. An absolute minimum was reached between 1967 and 1973 when no DCM established with a recovering to the end of the time series. Long-term variability of the DCM was related to the North Atlantic Oscillation with a time delay of 9 years. The marked decrease in the 1940s was correlated to the drop of the solar radiation in transition from early brightening to global dimming. Caused by the influence of the solar radiation and maybe related to increasing global temperatures in the last century, the integrated chlorophyll a concentration decreased by about 0.7 mg m−2 in 2008 compared to 1871. The high-resolved chlorophyll a hindcast allowed an estimation of the carbon uptake by the ocean due to primary production in the euphotic zone. A rough calculation over the area of the global subtropical oceans showed 700 megaton less carbon uptake in 2008

    The highly accurate anteriolateral portal for injecting the knee

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The extended knee lateral midpatellar portal for intraarticular injection of the knee is accurate but is not practical for all patients. We hypothesized that a modified anteriolateral portal where the synovial membrane of the medial femoral condyle is the target would be highly accurate and effective for intraarticular injection of the knee.</p> <p>Methods</p> <p>83 subjects with non-effusive osteoarthritis of the knee were randomized to intraarticular injection using the modified anteriolateral bent knee versus the standard lateral midpatellar portal. After hydrodissection of the synovial membrane with lidocaine using a mechanical syringe (reciprocating procedure device), 80 mg of triamcinolone acetonide were injected into the knee with a 2.0-in (5.1-cm) 21-gauge needle. Baseline pain, procedural pain, and pain at outcome (2 weeks and 6 months) were determined with the 10 cm Visual Analogue Pain Score (VAS). The accuracy of needle placement was determined by sonographic imaging.</p> <p>Results</p> <p>The lateral midpatellar and anteriolateral portals resulted in equivalent clinical outcomes including procedural pain (VAS midpatellar: 4.6 ± 3.1 cm; anteriolateral: 4.8 ± 3.2 cm; p = 0.77), pain at outcome (VAS midpatellar: 2.6 ± 2.8 cm; anteriolateral: 1.7 ± 2.3 cm; p = 0.11), responders (midpatellar: 45%; anteriolateral: 56%; p = 0.33), duration of therapeutic effect (midpatellar: 3.9 ± 2.4 months; anteriolateral: 4.1 ± 2.2 months; p = 0.69), and time to next procedure (midpatellar: 7.3 ± 3.3 months; anteriolateral: 7.7 ± 3.7 months; p = 0.71). The anteriolateral portal was 97% accurate by real-time ultrasound imaging.</p> <p>Conclusion</p> <p>The modified anteriolateral bent knee portal is an effective, accurate, and equivalent alternative to the standard lateral midpatellar portal for intraarticular injection of the knee.</p> <p>Trial Registration</p> <p>ClinicalTrials.gov: <a href="http://www.clinicaltrials.gov/ct2/show/NCT00651625">NCT00651625</a></p

    Predictors of response to intra-articular steroid injections in knee osteoarthritis-a systematic review

    Get PDF
    Objective: IA steroid injections (IASIs) have been shown to relieve pain in knee OA and are widely used in clinical practice. There is, however, evidence of some variation in response. Knowledge of predictors of response could aid in the selection of patients for this therapy. The aim of this systematic review was to determine factors associated with response to IASI in knee OA. Methods: Medline, Embase, AMED, CINAHL, Web of Science and Cochrane Central Registers for Controlled Trials up to January 2012 were searched with additional hand searches of relevant articles. Studies included were those that involved adults diagnosed with knee OA in whom IASIs were administered and factors that predicted treatment response were investigated. Results: Eleven publications meeting these criteria were reviewed and relevant information extracted. It was not possible to pool the results because of the different predictors studied, variable outcome measures, different criteria for symptom change and missing data. Given the relative paucity of data and small heterogeneously designed studies, it was difficult to identify predictors of response. Data from individual publications, although not consistent across studies, suggest that the presence of effusion, withdrawal of fluid from the knee, severity of disease, absence of synovitis, injection delivery under US guidance and greater symptoms at baseline may all improve the likelihood of response to IASI. Conclusion: Further larger-scale studies using standardized methods are required to characterize predictors of response and should focus on synovitis, effusion, pain and structural severity of disease. Such data would help in better targeting therapy to those most likely to benefit. © The Author 2012. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved

    The Kuramoto model in complex networks

    Get PDF
    181 pages, 48 figures. In Press, Accepted Manuscript, Physics Reports 2015 Acknowledgments We are indebted with B. Sonnenschein, E. R. dos Santos, P. Schultz, C. Grabow, M. Ha and C. Choi for insightful and helpful discussions. T.P. acknowledges FAPESP (No. 2012/22160-7 and No. 2015/02486-3) and IRTG 1740. P.J. thanks founding from the China Scholarship Council (CSC). F.A.R. acknowledges CNPq (Grant No. 305940/2010-4) and FAPESP (Grants No. 2011/50761-2 and No. 2013/26416-9) for financial support. J.K. would like to acknowledge IRTG 1740 (DFG and FAPESP).Peer reviewedPreprin

    Planetary Rings

    Full text link
    Planetary rings are the only nearby astrophysical disks, and the only disks that have been investigated by spacecraft. Although there are significant differences between rings and other disks, chiefly the large planet/ring mass ratio that greatly enhances the flatness of rings (aspect ratios as small as 1e-7), understanding of disks in general can be enhanced by understanding the dynamical processes observed at close-range and in real-time in planetary rings. We review the known ring systems of the four giant planets, as well as the prospects for ring systems yet to be discovered. We then review planetary rings by type. The main rings of Saturn comprise our system's only dense broad disk and host many phenomena of general application to disks including spiral waves, gap formation, self-gravity wakes, viscous overstability and normal modes, impact clouds, and orbital evolution of embedded moons. Dense narrow rings are the primary natural laboratory for understanding shepherding and self-stability. Narrow dusty rings, likely generated by embedded source bodies, are surprisingly found to sport azimuthally-confined arcs. Finally, every known ring system includes a substantial component of diffuse dusty rings. Planetary rings have shown themselves to be useful as detectors of planetary processes around them, including the planetary magnetic field and interplanetary impactors as well as the gravity of nearby perturbing moons. Experimental rings science has made great progress in recent decades, especially numerical simulations of self-gravity wakes and other processes but also laboratory investigations of coefficient of restitution and spectroscopic ground truth. The age of self-sustained ring systems is a matter of debate; formation scenarios are most plausible in the context of the early solar system, while signs of youthfulness indicate at least that rings have never been static phenomena.Comment: 82 pages, 34 figures. Final revision of general review to be published in "Planets, Stars and Stellar Systems", P. Kalas and L. French (eds.), Springer (http://refworks.springer.com/sss

    Improved functionalization of oleic acid-coated iron oxide nanoparticles for biomedical applications

    Get PDF
    Superparamagnetic iron oxide nanoparticles can providemultiple benefits for biomedical applications in aqueous environments such asmagnetic separation or magnetic resonance imaging. To increase the colloidal stability and allow subsequent reactions, the introduction of hydrophilic functional groups onto the particles’ surface is essential. During this process, the original coating is exchanged by preferably covalently bonded ligands such as trialkoxysilanes. The duration of the silane exchange reaction, which commonly takes more than 24 h, is an important drawback for this approach. In this paper, we present a novel method, which introduces ultrasonication as an energy source to dramatically accelerate this process, resulting in high-quality waterdispersible nanoparticles around 10 nmin size. To prove the generic character, different functional groups were introduced on the surface including polyethylene glycol chains, carboxylic acid, amine, and thiol groups. Their colloidal stability in various aqueous buffer solutions as well as human plasma and serum was investigated to allow implementation in biomedical and sensing applications.status: publishe

    The Physics of the B Factories

    Get PDF
    This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    corecore