14 research outputs found

    High-current pulse electron accelerators based on stepped forming lines

    No full text
    There presented is a brief review of I-3000, STRAUS, STRAUS-2 and LIA-10M accelerators produced in VNIIEF over the period from 1981 to 1994. All the installations function in the mode of single pulses. Their distinction consists in using the systems of forming high-voltage pulses on the basis of stepped forming lines. Such installations formed of line sections of a similar electrical length with a stepped character of impedance variance provide a high efficiency and as a result of wave processes increase for a several time the output voltage as compared to the charge voltage of lines. The limiting energy of accelerated electrons for the created accelerators lies within the range from 2.3 to 25 MeV, beam current amplitude – from 20 to 50 kA, current pulse width at half-height – from 16 to 40 ns. The basic characteristics of each accelerator are presented

    Marx generator GIN-1000 with 1 MV output voltage and 80 kJ stored energy

    No full text
    The results of development and study of Marx generator with output voltage of 1 MV and stored energy of 80 kJ are reported. The measured value of generator inductance is ~1.3 µH, the measured effective ohmic resistance ~ 1 Ohm.Приведены результаты разработки и исследования генератора Маркса с выходным напряжением 1 МВ, запасаемой энергией 80 кДж. Измеренное значение индуктивности генератора составляет ~1,3 мкГн, измеренное эффективное омическое сопротивление ~1 Ом.Наведено результати розробки і дослідження генератора Маркса з вихідною напругою 1 МВ, що запасає енергією 80 кДж. Виміряне значення індуктивності генератора становить ~1,3 мкГн, виміряний ефективний омічний опір ~1 Ом

    A high resolution electromagnetic calorimeter based on lead-tungstate crystals

    No full text
    A large-scale prototype of the PHOS electromagnetic spectrometer, which is part of the ALICE detector, has been built and tested. This prototype has 256 detector channels and is operated at −25 °C. Each detector channel is a lead-tungstate crystal coupled to an Avalanche Photo-Diode with a low-noise preamplifier. The prototype includes a 16×16 crystal matrix, photo-detectors, analog and digital electronics, a thermo-stabilized cooling system, a light-emitting diode monitoring system, and a charged-particle detector acting as veto counter. Results of measurements using electron and hadron beams of the CERN PS and SPS accelerators are discussed, and the performance of the prototype is evaluated

    Transverse momentum spectra of charged particles in proton-proton collisions at 1as=900 GeV with ALICE at the LHC

    No full text
    The inclusive charged particle transverse momentum distribution is measured in proton-proton collisions at s=900 GeV at the LHC using the ALICE detector. The measurement is performed in the central pseudorapidity region (|\u3b7|<0.8) over the transverse momentum range 0.15<10 GeV/c. The correlation between transverse momentum and particle multiplicity is also studied. Results are presented for inelastic (INEL) and non-single-diffractive (NSD) events. The average transverse momentum for |\u3b7|<0.8 is \u3008pT\u3009INEL=0.483\ub10.001 (stat.)\ub10.007 (syst.) GeV/c and \u3008pT\u3009NSD=0.489\ub10.001 (stat.)\ub10.007 (syst.) GeV/c, respectively. The data exhibit a slightly larger \u3008pT\u3009 than measurements in wider pseudorapidity intervals. The results are compared to simulations with the Monte Carlo event generators PYTHIA and PHOJET. \ua9 2010

    The forward muon spectrometer of ALICE

    No full text

    ALICE Technical Design Report of the Computing

    No full text
    ALICE, EI PHASE SE