31 research outputs found

    Optic disc classification by the Heidelberg Retina Tomograph and by physicians with varying experience of glaucoma

    Get PDF
    PurposeTo compare the diagnostic accuracy of the Heidelberg Retina Tomograph's (HRT) Moorfields regression analysis (MRA) and glaucoma probability score (GPS) with that of subjective grading of optic disc photographs performed by ophthalmologists with varying experience of glaucoma and by ophthalmology residents.MethodsDigitized disc photographs and HRT images from 97 glaucoma patients with visual field defects and 138 healthy individuals were classified as either within normal limits (WNL), borderline (BL), or outside normal limits (ONL). Sensitivity and specificity were compared for MRA, GPS, and the physicians. Analyses were also made according to disc size and for advanced visual field loss.ResultsForty-five physicians participated. When BL results were regarded as normal, sensitivity was significantly higher (P<5%) for both MRA and GPS compared with the average physician, 87%, 79%, and 62%, respectively. Specificity ranged from 86% for MRA to 97% for general ophthalmologists, but the differences were not significant. In eyes with small discs, sensitivity was 75% for MRA, 60% for the average doctor, and 25% for GPS; in eyes with large discs, sensitivity was 100% for both GPS and MRA, but only 68% for physicians.ConclusionOur results suggest that sensitivity of MRA is superior to that of the average physician, but not that of glaucoma experts. MRA correctly classified all eyes with advanced glaucoma and showed the best sensitivity in eyes with small optic discs

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6·9 per cent) from low-HDI, 254 (15·5 per cent) from middle-HDI and 1268 (77·6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57·5, 40·9 and 35·4 per cent; P < 0·001) and subsequent use of end colostomy (52·2, 24·8 and 18·9 per cent; P < 0·001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3·20, 95 per cent c.i. 1·35 to 7·57; P = 0·008) after risk adjustment for malignant disease (OR 2·34, 1·65 to 3·32; P < 0·001), emergency surgery (OR 4·08, 2·73 to 6·10; P < 0·001), time to operation at least 48 h (OR 1·99, 1·28 to 3·09; P = 0·002) and disease perforation (OR 4·00, 2·81 to 5·69; P < 0·001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Glaucoma versus red disease

    No full text
    The use of ophthalmic imaging for documentation and diagnosis of ocular disease is rising dramatically. Optical coherence tomography (OCT), confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and photographic imaging of the optic nerve head (ONH) are currently used to document baseline characteristics of the ONH and for diagnosing glaucoma and glaucoma progression secondary to loss of retinal nerve fiber layer (RNFL). Imaging modalities typically provide information on ONH and RNFL characteristics which are outside of the normal (relative to normative databases) in red lettering or boxes, whereas ONH and RNFL characteristics within the normal range are presented in green. As imaging modalities have become more sophisticated and are validated in research studies, clinicians have come to rely upon data from these imaging devices to aid in differentiating between normal and glaucomatous states of the ONH and RNFL - typically by examining if the data are green or red suggesting normal or abnormal. However, normative databases can sometimes be flawed relative to atypical ONH or RNFL morphologies and imaging can provide artifacts which do not represent true ocular disease but secondary to limitations of imaging technology. Ophthalmic imaging is an important adjunct to clinical diagnosis but the results from imaging devices need to be assessed critically relative to artifacts of imaging and the limitations of the technology and its normative databases

    Retinal Nerve Fiber and Optic Disc Morphology in Patients with Human Immunodeficiency Virus Using the Heidelberg Retina Tomography 3

    No full text
    PURPOSE:To use novel confocal scanning ophthalmoscopy technology to test hypothesis that HIV-seropositive patients without history of retinitis with a history of a low CD4 count are more likely to have damage to their retinal nerve fiber layer (RNFL) when compared to patients with high CD4 count. In addition, we compared optic disc morphologic changes with glaucoma. DESIGN:Cross-sectional study. PARTICIPANTS AND CONTROLS:171 patients were divided into four groups. The control group consisted of 40 eyes of 20 HIV-seronegative patients. The second group consisted of 80 eyes of 41 HIV-positive patients whose CD4 cell count never dropped below 100 (1.0 x 10(9)/L). The third group consisted of 44 eyes of 26 HIV-positive patients with a history of low CD4 counts <100. Fourth group consisted of 79 eyes of 79 patients with confirmed glaucoma who served as positive controls. TESTING:Confocal scanning laser ophthalmoscopy was performed with the Heidelberg Retina Tomograph (HRT3) and data were analyzed with HRT3, software (Heyex version 1.5.10.0). MAIN OUTCOME MEASURES:Disc area, cup area, cup volume, rim volume, mean cup depth, maximum cup depth, cup-to-disc ration, mean RNFL thickness, and RNFL cross-sectional area. RESULTS:Analysis of the global optic nerve and cup parameters showed no difference in disk area among the four groups. There was also no difference in cup, rim volume, mean cup depth, or maximum cup depth among the first three groups but they were all different from glaucoma group. The RNFL was thinner in glaucoma and both HIV-positive groups compared to HIV-seronegative subjects. The cross sectional RNFL area was thinner in both high and low CD4 HIV-positive groups compared to HIV-seronegative group in the nasal and temporal/inferior sectors, respectively. Glaucoma group showed thinning in all sectors. CONCLUSIONS:HIV retinopathy results in retinal nerve fiber layer loss without structural optic nerve supportive tissue change. RNFL damage may occur early in HIV disease by mechanism different than in glaucoma
    corecore