1,243 research outputs found

    The incidence of postoperative venous thrombosis among patients with ulcerative colitis

    Get PDF
    Background: Patients with Ulcerative Colitis (UC) have inherent prothrombotic tendencies. It is unknown whether this necessitates the use of additional perioperative anti-thrombotic prophylaxis when such patients require major surgery. Methods: The postoperative courses of 79 patients with UC undergoing 180 major abdominal and pelvic operations were examined for clinical and radiological evidence of venous thrombosis. Eighteen patients with Familial Adenomatous Polyposis (FAP) having surgery (35 operations) of similar magnitude were also studied. Standard anti-thrombosis prophylaxis was utilised in all patients. Results: Nine patients with UC were clinically suspected of developing postoperative venous thrombosis, but only three (3.8%) had their diagnosis confirmed radiologically (all had a pulmonary embolus). Therefore, the overall postoperative thrombosis rate, on an intention to treat basis, was 1.7% (3/180). No patient with FAP developed significant venous thrombosis. Conclusion: Standard perioperative antithrombotic modalities are sufficient to maintain any potential increase in postoperative thrombotic risk at an acceptable level in patients with UC undergoing operative intervention

    Palliative gastrostomy in the setting of voluminous ascites

    Get PDF
    Objective: We report the indications, methods, and complications of percutaneous gastrostomy/gastrojejunostomy (G/GJ) in patients with voluminous ascites. Methods: Following institutional review board approval, 69 patients (14 male, 55 female, mean age 58±12 years, range 32–89 years) who underwent percutaneous G/GJ with paracentesis were identified from a prospectively acquired database. Electronic medical record data extracted included diagnosis, method of G/GJ insertion, clinical course, and complications, which were graded by The Society of Interventional Radiology (SIR) criteria. Statistics were performed using Graphpad Instat. Results: Sixty-six G and three GJ catheters were placed in 62 patients with malignant and 7 patients with benign disease; 47 procedures were conducted using fluoroscopy and 22 using computed tomography (CT; 10 patients had failed fluoroscopy). Sixty-six patients had 1980±1371 mL (range, 20–5000 mL) ascites drained (more in males, p=0.01) 0.8±1.6 days (range, 0–5 days) prior to placement. Forty-one patients had significantly less ascites (1895±1426 mL; range, 100–5400 mL) drained after G/GJ (p>0.0.5). Mean survival after insertion was 43±57 days (range, 1–252 days) among 38 patients for whom data were available. Fifty-six patients had a mean postprocedure hospital stay of 8.6±8.4 days (range, 0–45 days); 3 were outpatients and 10 patients died in the hospital. Successful gastropexy was confirmed on subsequent cross-sectional imaging in 22 of 25 patients. There were 25 tube maintenance issues that included catheter displacement and leakage, one patient experienced hemorrhage, and there were two deaths. All except one patient had satisfactory gastrostomy function. Conclusion: Effective G/GJ placement is possible in most patients with voluminous ascites provided ascites is drained and gastrocutaneous fistula formation occurs. Caution is advised; placement is generally for fragile terminal patients, and fluoroscopy or CT guidance is required

    Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades

    Get PDF
    Objective: With the increasing life expectancy for patients with cystic fibrosis (CF), and a known predisposition to certain cancers, cumulative radiation exposure from radiologic imaging is of increasing significance. This study explores the estimated cumulative effective radiation dose over a 17-year period from radiologic procedures and changing trends of imaging modalities over this period. Methods: Estimated cumulative effective dose (CED) from all thoracic and extrathoracic imaging modalities and interventional radiology procedures for both adult and pediatric patients with CF, exclusively attending a nationally designated CF center between 1992-2009 for > 1 year, was determined. The study period was divided into three equal tertiles, and estimated CED attributable to all radiologic procedures was estimated for each tertile. Results: Two hundred thirty patients met inclusion criteria (2,240 person-years of follow-up; 5,596 radiologic procedures). CED was > 75 mSv for one patient (0.43%), 36 patients (15.6%) had a CED between 20 and 75 mSv, 56 patients (24.3%) had a CED between 5 and 20 mSv, and in 138 patients (60%) the CED was estimated to be between 0 and 5 mSv over the study period. The mean annual CED per patient increased consecutively from 0.39 mSv/y to 0.47 mSv/y to 1.67 mSv/y over the tertiles one to three of the study period, respectively (P < .001). Thoracic imaging accounted for 46.9% of the total CED and abdominopelvic imaging accounted for 42.9% of the CED, respectively. There was an associated 5.9-fold increase in the use of all CT scanning per patient (P < .001). Conclusions: This study highlights the increasing exposure to ionizing radiation to patients with CF as a result of diagnostic imaging, primarily attributable to CT scanning. Increased awareness of CED and strategies to reduce this exposure are needed

    The impact of routine open nonsuction drainage on fluid accumulation after thyroid surgery: a prospective randomised clinical trial.

    Get PDF
    Background: Thyroid drains following thyroid surgery are routinely used despite minimal supportive evidence. Our aim in this study is to determine the impact of routine open drainage of the thyroid bed postoperatively on ultrasound-determined fluid accumulation at 24 hours. Methods: We conducted a prospective randomised clinical trial on patients undergoing thyroid surgery. Patients were randomly assigned to a drain group (n = 49) or a no-drain group (n = 44) immediately prior to wound closure. Patients underwent a neck ultrasound on day 1 and day 2 postoperatively. After surgery, we evaluated visual analogue scale pain scores, postoperative analgesic requirements, self-reported scar satisfaction at 6 weeks and complications. Results: There was significantly less mean fluid accumulated in the drain group on both day 1, 16.4 versus 25.1 ml (P-value = 0.005), and day 2, 18.4 versus 25.7 ml (P-value = 0.026), following surgery. We found no significant differences between the groups with regard to length of stay, scar satisfaction, visual analogue scale pain score and analgesic requirements. There were four versus one wound infections in the drain versus no-drain groups. This finding was not statistically significant (P = 0.154). No life-threatening bleeds occurred in either group. Conclusions: Fluid accumulation after thyroid surgery was significantly lessened by drainage. However, this study did not show any clinical benefit associated with this finding in the non-emergent setting. Drains themselves showed a trend indicating that they may augment infection rates. The results of this study suggest that the frequency of acute life-threatening bleeds remains extremely low following abandoning drains. We advocate abandoning routine use of thyroid drains. Trial registration: ISRCTN94715414

    Optimizing parameters of an open-source airway segmentation algorithm using different CT images.

    Get PDF
    Background: Computed tomography (CT) helps physicians locate and diagnose pathological conditions. In some conditions, having an airway segmentation method which facilitates reconstruction of the airway from chest CT images can help hugely in the assessment of lung diseases. Many efforts have been made to develop airway segmentation algorithms, but methods are usually not optimized to be reliable across different CT scan parameters. Methods: In this paper, we present a simple and reliable semi-automatic algorithm which can segment tracheal and bronchial anatomy using the open-source 3D Slicer platform. The method is based on a region growing approach where trachea, right and left bronchi are cropped and segmented independently using three different thresholds. The algorithm and its parameters have been optimized to be efficient across different CT scan acquisition parameters. The performance of the proposed method has been evaluated on EXACT’09 cases and local clinical cases as well as on a breathing pig lung phantom using multiple scans and changing parameters. In particular, to investigate multiple scan parameters reconstruction kernel, radiation dose and slice thickness have been considered. Volume, branch count, branch length and leakage presence have been evaluated. A new method for leakage evaluation has been developed and correlation between segmentation metrics and CT acquisition parameters has been considered. Results: All the considered cases have been segmented successfully with good results in terms of leakage presence. Results on clinical data are comparable to other teams’ methods, as obtained by evaluation against the EXACT09 challenge, whereas results obtained from the phantom prove the reliability of the method across multiple CT platforms and acquisition parameters. As expected, slice thickness is the parameter affecting the results the most, whereas reconstruction kernel and radiation dose seem not to particularly affect airway segmentation. Conclusion: The system represents the first open-source airway segmentation platform. The quantitative evaluation approach presented represents the first repeatable system evaluation tool for like-for-like comparison between different airway segmentation platforms. Results suggest that the algorithm can be considered stable across multiple CT platforms and acquisition parameters and can be considered as a starting point for the development of a complete airway segmentation algorithm

    Search for chargino-neutralino production with mass splittings near the electroweak scale in three-lepton final states in √s=13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for supersymmetry through the pair production of electroweakinos with mass splittings near the electroweak scale and decaying via on-shell W and Z bosons is presented for a three-lepton final state. The analyzed proton-proton collision data taken at a center-of-mass energy of √s=13  TeV were collected between 2015 and 2018 by the ATLAS experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 139  fb−1. A search, emulating the recursive jigsaw reconstruction technique with easily reproducible laboratory-frame variables, is performed. The two excesses observed in the 2015–2016 data recursive jigsaw analysis in the low-mass three-lepton phase space are reproduced. Results with the full data set are in agreement with the Standard Model expectations. They are interpreted to set exclusion limits at the 95% confidence level on simplified models of chargino-neutralino pair production for masses up to 345 GeV

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    A First Search for coincident Gravitational Waves and High Energy Neutrinos using LIGO, Virgo and ANTARES data from 2007

    Get PDF
    We present the results of the first search for gravitational wave bursts associated with high energy neutrinos. Together, these messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, particularly at high energy. Our search uses neutrinos detected by the underwater neutrino telescope ANTARES in its 5 line configuration during the period January - September 2007, which coincided with the fifth and first science runs of LIGO and Virgo, respectively. The LIGO-Virgo data were analysed for candidate gravitational-wave signals coincident in time and direction with the neutrino events. No significant coincident events were observed. We place limits on the density of joint high energy neutrino - gravitational wave emission events in the local universe, and compare them with densities of merger and core-collapse events.Comment: 19 pages, 8 figures, science summary page at http://www.ligo.org/science/Publication-S5LV_ANTARES/index.php. Public access area to figures, tables at https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=p120000

    Search for lepton-flavor violation in different-flavor, high-mass final states in pp collisions at √s=13 TeV with the ATLAS detector

    Get PDF
    A search is performed for a heavy particle decaying into different-flavor, dilepton pairs (eμ, eτ or μτ), using 36.1  fb−1 of proton-proton collision data at √s=13  TeV collected in 2015–2016 by the ATLAS detector at the Large Hadron Collider. No excesses over the Standard Model predictions are observed. Bayesian lower limits at the 95% credibility level are placed on the mass of a Z′ boson, the mass of a supersymmetric τ-sneutrino, and on the threshold mass for quantum black-hole production. For the Z′ and sneutrino models, upper cross-section limits are converted to upper limits on couplings, which are compared with similar limits from low-energy experiments and which are more stringent for the eτ and μτ modes
    corecore