1,019 research outputs found
Entropy of the Schwarzschild black hole to all orders in the Planck length
Considering corrections to all orders in the Planck length on the quantum
state density from a generalized uncertainty principle (GUP), we calculate the
statistical entropy of the scalar field on the background of the Schwarzschild
black hole without any cutoff. We obtain the entropy of the massive scalar
field proportional to the horizon area.Comment: 13 pages, 1 figure; Minor typos corrected, one reference added;
Accepted for publication in Phys. Lett.
Random Matrix Theories in Quantum Physics: Common Concepts
We review the development of random-matrix theory (RMT) during the last
decade. We emphasize both the theoretical aspects, and the application of the
theory to a number of fields. These comprise chaotic and disordered systems,
the localization problem, many-body quantum systems, the Calogero-Sutherland
model, chiral symmetry breaking in QCD, and quantum gravity in two dimensions.
The review is preceded by a brief historical survey of the developments of RMT
and of localization theory since their inception. We emphasize the concepts
common to the above-mentioned fields as well as the great diversity of RMT. In
view of the universality of RMT, we suggest that the current development
signals the emergence of a new "statistical mechanics": Stochasticity and
general symmetry requirements lead to universal laws not based on dynamical
principles.Comment: 178 pages, Revtex, 45 figures, submitted to Physics Report
A Novel Animal Model of Borrelia recurrentis Louse-Borne Relapsing Fever Borreliosis Using Immunodeficient Mice
Louse-borne relapsing fever (LBRF) borreliosis is caused by Borrelia recurrentis, and it is a deadly although treatable disease that is endemic in the Horn of Africa but has epidemic potential. Research on LBRF has been severely hampered because successful infection with B. recurrentis has been achieved only in primates (i.e., not in other laboratory or domestic animals). Here, we present the first non-primate animal model of LBRF, using SCID (-B, -T cells) and SCID BEIGE (-B, -T, -NK cells) immunocompromised mice. These animals were infected with B. recurrentis A11 or A17, or with B. duttonii 1120K3 as controls. B. recurrentis caused a relatively mild but persistent infection in SCID and SCID BEIGE mice, but did not proliferate in NUDE (-T) and BALB/c (wild-type) mice. B. duttonii was infectious but not lethal in all animals. These findings demonstrate that the immune response can limit relapsing fever even in the absence of humoral defense mechanisms. To study the significance of phagocytic cells in this context, we induced systemic depletion of such cells in the experimental mice by injecting them with clodronate liposomes, which resulted in uncontrolled B. duttonii growth and a one-hundred-fold increase in B. recurrentis titers in blood. This observation highlights the role of macrophages and other phagocytes in controlling relapsing fever infection. B. recurrentis evolved from B. duttonii to become a primate-specific pathogen that has lost the ability to infect immunocompetent rodents, probably through genetic degeneration. Here, we describe a novel animal model of B. recurrentis based on B- and T-cell-deficient mice, which we believe will be very valuable in future research on LBRF. Our study also reveals the importance of B-cells and phagocytes in controlling relapsing fever infection
Ambulatory monitoring demonstrates an acute association between cookstove-related carbon monoxide and blood pressure in a Ghanaian cohort
Background
Repeated exposure to household air pollution may intermittently raise blood pressure (BP) and affect cardiovascular outcomes. We investigated whether hourly carbon monoxide (CO) exposures were associated with acute increases in ambulatory blood pressure (ABP); and secondarily, if switching to an improved cookstove was associated with BP changes. We also evaluated the feasibility of using 24-h ambulatory blood pressure monitoring (ABPM) in a cohort of pregnant women in Ghana.
Methods
Participants were 44 women enrolled in the Ghana Randomized Air Pollution and Health Study (GRAPHS). For 27 of the women, BP was measured using 24-h ABPM; home blood pressure monitoring (HBPM) was used to measure BP in the remaining 17 women. Personal CO exposure monitoring was conducted alongside the BP monitoring.
Results
ABPM revealed that peak CO exposure (defined as ≥4.1 ppm) in the 2 hours prior to BP measurement was associated with elevations in hourly systolic BP (4.3 mmHg [95% CI: 1.1, 7.4]) and diastolic BP (4.5 mmHg [95% CI: 1.9, 7.2]), as compared to BP following lower CO exposures. Women receiving improved cookstoves had lower post-intervention SBP (within-subject change in SBP of −2.1 mmHg [95% CI: -6.6, 2.4] as compared to control), though this result did not reach statistical significance. 98.1% of expected 24-h ABPM sessions were successfully completed, with 92.5% of them valid according to internationally defined criteria.
Conclusions
We demonstrate an association between acute exposure to carbon monoxide and transient increases in BP in a West African setting. ABPM shows promise as an outcome measure for assessing cardiovascular health benefits of cookstove interventions
Circulating KRAS G12D but not G12V is associated with survival in metastatic pancreatic ductal adenocarcinoma
While high circulating tumor DNA (ctDNA) levels are associated with poor survival for multiple cancers, variant-specific differences in the association of ctDNA levels and survival have not been examined. Here we investigate KRAS ctDNA (ctKRAS) variant-specific associations with overall and progression-free survival (OS/PFS) in first-line metastatic pancreatic ductal adenocarcinoma (mPDAC) for patients receiving chemoimmunotherapy ("PRINCE", NCT03214250), and an independent cohort receiving standard of care (SOC) chemotherapy. For PRINCE, higher baseline plasma levels are associated with worse OS for ctKRAS G12D (log-rank p = 0.0010) but not G12V (p = 0.7101), even with adjustment for clinical covariates. Early, on-therapy clearance of G12D (p = 0.0002), but not G12V (p = 0.4058), strongly associates with OS for PRINCE. Similar results are obtained for the SOC cohort, and for PFS in both cohorts. These results suggest ctKRAS G12D but not G12V as a promising prognostic biomarker for mPDAC and that G12D clearance could also serve as an early biomarker of response
Impact of magnetic field on the stability of the CMS GE1/1 GEM detector operation
The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7 of October 2021. During the magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. In order to reproduce the behavior, it was decided to conduct a dedicated test at the CERN North Area with the Goliath magnet, using four GE1/1 spare chambers. The test consisted in studying the characteristics of discharge events that occurred in different detector configurations and external conditions. Multiple magnetic field ramps were performed in sequence: patterns in the evolution of the discharge rates were observed with these data. The goal of this test is the understanding of the experimental conditions inducing discharges and short circuits in a GEM foil.
The results of this test lead to the development of procedure for the optimal operation and performance of GEM detectors in the CMS experiment during the magnet ramps. Another important result is the estimation of the probability of short circuit generation, at 68 % confidence level, p = 0.42% with detector HV OFF and p < 0.49% with the HV ON. These numbers are specific for the detectors used during this test, but they provide a first quantitative indication on the phenomenon, and a point of comparison for future studies adopting the same procedure
Benchmarking LHC background particle simulation with the CMS triple-GEM detector
In 2018, a system of large-size triple-GEM demonstrator chambers was installed in the CMS experiment at CERN\u27s Large Hadron Collider (LHC). The demonstrator\u27s design mimicks that of the final detector, installed for Run-3. A successful Monte Carlo (MC) simulation of the collision-induced background hit rate in this system in proton-proton collisions at 13 TeV is presented. The MC predictions are compared to CMS measurements recorded at an instantaneous luminosity of 1.5 ×10 cm s. The simulation framework uses a combination of the FLUKA and GEANT4 packages. FLUKA simulates the radiation environment around the GE1/1 chambers. The particle flux by FLUKA covers energy spectra ranging from 10 to 10 MeV for neutrons, 10 to 10 MeV for γ\u27s, 10 to 10 MeV for e, and 10 to 10 MeV for charged hadrons. GEANT4 provides an estimate of the detector response (sensitivity) based on an accurate description of the detector geometry, the material composition, and the interaction of particles with the detector layers. The detector hit rate, as obtained from the simulation using FLUKA and GEANT4, is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties in the range 13.7-14.5%. This simulation framework can be used to obtain a reliable estimate of the background rates expected at the High Luminosity LHC
Modeling the triple-GEM detector response to background particles for the CMS Experiment
An estimate of environmental background hit rate on triple-GEM chambers is
performed using Monte Carlo (MC) simulation and compared to data taken by test
chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large
Hadron Collider (LHC). The hit rate is measured using data collected with
proton-proton collisions at 13 TeV and a luminosity of 1.5
cm s. The simulation framework uses a combination of the FLUKA
and Geant4 packages to obtain the hit rate. FLUKA provides the radiation
environment around the GE1/1 chambers, which is comprised of the particle flux
with momentum direction and energy spectra ranging from to
MeV for neutrons, to MeV for 's, to
MeV for , and to MeV for charged hadrons.
Geant4 provides an estimate of detector response (sensitivity) based on an
accurate description of detector geometry, material composition and interaction
of particles with the various detector layers. The MC simulated hit rate is
estimated as a function of the perpendicular distance from the beam line and
agrees with data within the assigned uncertainties of 10-14.5%. This simulation
framework can be used to obtain a reliable estimate of background rates
expected at the High Luminosity LHC.Comment: 16 pages, 9 figures, 6 table
- …