9 research outputs found

    Errors associated with particulate matter measurements on rural sources: appropriate basis for regulating cotton gins

    Get PDF
    Agricultural operations across the United States are encountering difficulties complying with current air pollution regulations for particulate matter (PM). PM is currently regulated in terms of particle diameters less than or equal to a nominal 10 μm (PM10); however, current legislation is underway to regulate PM with diameters less than or equal to a nominal 2.5 μm (PM2.5). The goals of this research were to determine the biases and uncertainties associated with current PM10 and PM2.5 sampling methods and to determine the extent to which these errors may impact the determination of cotton gin emission factors. Ideally, PM samplers would produce an accurate measure of the pollutant indicator; for instance, a PM10 sampler would produce an accurate measure of PM less than or equal to 10 μm. However, samplers are not perfect and errors are introduced because of the established tolerances associated with sampler performance characteristics and the interaction of particle size and sampler performance characteristics. Results of this research indicated that a source emitting PM characterized by a mass median diameter (MMD) of 20 μm and a geometric standard deviation (GSD) of 1.5 could be forced to comply with a 3.2 and 14 times more stringent regulation of PM10 and PM2.5, respectively, than a source emitting PM characterized by a MMD of 10 μm and a GSD of 1.5. These estimates are based on both sources emitting the same concentrations of true PM or concentrations corresponding to the particle diameters less than the size of interest. Various methods were used to estimate the true PM10 and PM2.5 emission factors associated with cotton gin exhausts and the extent to which the sampler errors impacted the PM regulation. Results from this research indicated that current cotton gin emission factors could be over-estimated by about 40%. This over-estimation is a consequence of the relatively large PM associated with cotton gin exhausts. These PM sampling errors are contributing to the misappropriation of source emissions in State Implementation Plans, essentially forcing Air Pollution Regulatory Agencies to require additional controls on sources that may be incorrectly classified has high emitters

    Rare Complications of Cervical Spine Surgery: Pseudomeningocoele.

    Get PDF
    STUDY DESIGN: This study was a retrospective, multicenter cohort study. OBJECTIVES: Rare complications of cervical spine surgery are inherently difficult to investigate. Pseudomeningocoele (PMC), an abnormal collection of cerebrospinal fluid that communicates with the subarachnoid space, is one such complication. In order to evaluate and better understand the incidence, presentation, treatment, and outcome of PMC following cervical spine surgery, we conducted a multicenter study to pool our collective experience. METHODS: This study was a retrospective, multicenter cohort study of patients who underwent cervical spine surgery at any level(s) from C2 to C7, inclusive; were over 18 years of age; and experienced a postoperative PMC. RESULTS: Thirteen patients (0.08%) developed a postoperative PMC, 6 (46.2%) of whom were female. They had an average age of 48.2 years and stayed in hospital a mean of 11.2 days. Three patients were current smokers, 3 previous smokers, 5 had never smoked, and 2 had unknown smoking status. The majority, 10 (76.9%), were associated with posterior surgery, whereas 3 (23.1%) occurred after an anterior procedure. Myelopathy was the most common indication for operations that were complicated by PMC (46%). Seven patients (53%) required a surgical procedure to address the PMC, whereas the remaining 6 were treated conservatively. All PMCs ultimately resolved or were successfully treated with no residual effects. CONCLUSIONS: PMC is a rare complication of cervical surgery with an incidence of less than 0.1%. They prolong hospital stay. PMCs occurred more frequently in association with posterior approaches. Approximately half of PMCs required surgery and all ultimately resolved without residual neurologic or other long-term effects

    C5 Palsy After Cervical Spine Surgery: A Multicenter Retrospective Review of 59 Cases.

    Get PDF
    STUDY DESIGN: A multicenter, retrospective review of C5 palsy after cervical spine surgery. OBJECTIVE: Postoperative C5 palsy is a known complication of cervical decompressive spinal surgery. The goal of this study was to review the incidence, patient characteristics, and outcome of C5 palsy in patients undergoing cervical spine surgery. METHODS: We conducted a multicenter, retrospective review of 13 946 patients across 21 centers who received cervical spine surgery (levels C2 to C7) between January 1, 2005, and December 31, 2011, inclusive. P values were calculated using 2-sample t test for continuous variables and χ(2) tests or Fisher exact tests for categorical variables. RESULTS: Of the 13 946 cases reviewed, 59 patients experienced a postoperative C5 palsy. The incidence rate across the 21 sites ranged from 0% to 2.5%. At most recent follow-up, 32 patients reported complete resolution of symptoms (54.2%), 15 had symptoms resolve with residual effects (25.4%), 10 patients did not recover (17.0%), and 2 were lost to follow-up (3.4%). CONCLUSION: C5 palsy occurred in all surgical approaches and across a variety of diagnoses. The majority of patients had full recovery or recovery with residual effects. This study represents the largest series of North American patients reviewed to date

    Group 2 ITI Consensus Report: Prosthodontics and implant dentistry

    Get PDF
    ObjectivesWorking Group 2 was convened to address topics relevant to prosthodontics and dental implants. Systematic reviews were developed according to focused questions addressing (a) the number of implants required to support fixed full‐arch restorations, (b) the influence of intentionally tilted implants compared to axial positioned implants when supporting fixed dental prostheses (FDPs), (c) implant placement and loading protocols, (d) zirconia dental implants, (e) zirconia and metal ceramic implant supported single crowns and (f) zirconia and metal ceramic implant supported FDPs.Materials and methodsGroup 2 considered and discussed information gathered in six systematic reviews. Group participants discussed statements developed by the authors and developed consensus. The group developed and found consensus for clinical recommendations based on both the statements and the experience of the group. The consensus statements and clinical recommendations were presented to the plenary (gathering of all conference attendees) and discussed. Final versions were developed after consensus was reached.ResultsA total of 27 consensus statements were developed from the systematic reviews. Additionally, the group developed 24 clinical recommendations based on the combined expertise of the participants and the developed consensus statements.ConclusionsThe literature supports the use of various implant numbers to support full‐arch fixed prostheses. The use of intentionally tilted dental implants is indicated when appropriate conditions exist. Implant placement and loading protocols should be considered together when planning and treating patients. One‐piece zirconia dental implants can be recommended when appropriate clinical conditions exist although two‐piece zirconia implants should be used with caution as a result of insufficient data. Clinical performance of zirconia and metal ceramic single implant supported crowns is similar and each demonstrates significant, though different, complications. Zirconia ceramic FDPs are less reliable than metal ceramic. Implant supported monolithic zirconia prostheses may be a future option with more supporting evidence.</p

    Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values

    No full text
    PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period

    Early loading after 21 days of healing of nonsubmerged titanium implants with a chemically modified sandblasted and acid-etched surface: two-year results of a prospective two-center study

    No full text
    PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up

    Group 2 ITI consensus report: prosthodontics and implant dentistry

    Get PDF
    Working Group 2 was convened to address topics relevant to prosthodontics and dental implants. Systematic reviews were developed according to focused questions addressing (a) the number of implants required to support fixed full-arch restorations, (b) the influence of intentionally tilted implants compared to axial positioned implants when supporting fixed dental prostheses (FDPs), (c) implant placement and loading protocols, (d) zirconia dental implants, (e) zirconia and metal ceramic implant supported single crowns and (f) zirconia and metal ceramic implant supported FDPs

    2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease

    No full text
    corecore