3,298 research outputs found

    Circulating Apolipoprotein E Concentration and Cardiovascular Disease Risk: Meta-analysis of Results from Three Studies

    Get PDF
    Background: The association of APOE genotype with circulating apolipoprotein E (ApoE) concentration and cardiovascular disease (CVD) risk is well established. However, the relationship of circulating ApoE concentration and CVD has received little attention. Methods and Findings: To address this, we measured circulating ApoE concentration in 9,587 individuals (with 1,413 CVD events) from three studies with incident CVD events: two population-based studies, the English Longitudinal Study of Ageing (ELSA) and the men-only Northwick Park Heart Study II (NPHSII), and a nested sub-study of the Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT). We examined the association of circulating ApoE with cardiovascular risk factors in the two population-based studies (ELSA and NPHSII) and the relationship between ApoE concentration and coronary heart disease and stroke in all three studies. Analyses were carried out within study, and, where appropriate, pooled effect estimates were derived using meta-analysis. In the population-based samples, circulating ApoE was associated with systolic blood pressure (correlation coefficient 0.08, p < 0.001, in both ELSA and NPHSII), total cholesterol (correlation coefficient 0.46 and 0.34 in ELSA and NPHSII, respectively; both p < 0.001), low-density lipoprotein cholesterol (correlation coefficient 0.30 and 0.14, respectively; both p < 0.001), high-density lipoprotein (correlation coefficient 0.16 and ?0.14, respectively; both p < 0.001), and triglycerides (correlation coefficient 0.43 and 0.46, respectivly; both p < 0.001). In NPHSII, ApoE concentration was additionally associated with apolipoprotein B (correlation coefficient 0.13, p = 0.001) and lipoprotein(a) (correlation coefficient ?0.11, p < 0.001). In the pooled analysis of ASCOT, ELSA, and NPHSII, there was no association of ApoE with CVD events; the odds ratio (OR) for CVD events per 1-standard-deviation higher ApoE concentration was 1.02 (95% CI 0.96, 1.09). After adjustment for cardiovascular risk factors, the OR for CVD per 1-standard-deviation higher ApoE concentration was 0.97 (95% CI 0.82, 1.15). Limitations of these analyses include a polyclonal method of ApoE measurement, rather than isoform-specific measurement, a moderate sample size (although larger than any other study to our knowledge and with a long lag between ApoE measures), and CVD events that may attenuate an effect. Conclusions: In the largest study to date on this question, we found no evidence of an association of circulating ApoE concentration with CVD events. The established association of APOE genotype with CVD events may be explained by isoform-specific functions as well as other mechanisms, rather than circulating concentrations of ApoE

    Case Report Treated Follicular Lymphoma, Recurrent Invasive Pneumococcal Disease, Nonresponsiveness to Vaccination, and a Unique Pneumococcus

    Get PDF
    A nonneutropenic patient with treated low-grade non-Hodgkin&apos;s (Follicular) lymphoma and secondary hypogammaglobulinemia recovered from pneumococcal pneumonia and septicemia (serotype 7F; ST191) subsequent to influenza A H1N1 (2009). Both infections were potentially vaccine preventable. The patient then developed pneumococcal meningitis due to a serotype 35F pneumococcus with a unique Multilocus Sequence Type (ST7004) which was not vaccine preventable. Patient management was influenced by host predisposition to pneumococcal infection, antibiotic intolerance, and poor response to polysaccharide pneumococcal vaccine. Indirect immunofluorescence with anti-human immunoglobulin confirmed a poor or intermediate response to Pneumovax II. Prophylactic erythromycin was initiated, and immunoglobulin transfusions were also commenced as a preventive strategy. ST7004 is a single locus variant of ST1635 which has been associated with the serotype 35F capsule in England. The spi gene in ST7004, which differentiates it from ST1635, is the same as the spi gene present in ST191 which could have arisen from the first disease episode suggesting that horizontal gene transfer may have occurred between different populations of pneumococci present within the patient in an attempt to evade vaccination selection pressure

    Cerebrospinal fluid cannot be used to distinguish inflammatory myelitis from congestive myelopathy due to spinal dural arteriovenous fistula: case series.

    Get PDF
    Patients with congestive myelopathy due to spinal dural arteriovenous fistula (SDAVF) typically present with progressive sensory and motor disturbance in association with sphincter dysfunction. Spinal MRI usually shows longitudinally extensive T2 signal change. Here, we report four patients with progressive myelopathy due to SDAVF who also presented with findings on cerebrospinal fluid (CSF) examination suggestive of an inflammatory aetiology. Such CSF findings in SDAVF are important to recognise, to avoid the erroneous diagnosis of an inflammatory myelitis and inappropriate treatment with immunosuppression. SDAVF can be difficult to detect and may require repeated investigation, with formal angiography as the gold standard

    Wearable technology in the sports medicine clinic to guide the return-to-play and performance protocols of athletes following a COVID-19 diagnosis

    Get PDF
    The coronavirus disease 2019 (COVID-19) pandemic has enabled the adoption of digital health platforms for self-monitoring and diagnosis. Notably, the pandemic has had profound effects on athletes and their ability to train and compete. Sporting organizations worldwide have reported a significant increase in injuries manifesting from changes in training regimens and match schedules resulting from extended quarantines. While current literature focuses on the use of wearable technology to monitor athlete workloads to guide training, there is a lack of literature suggesting how such technology can mediate the return to sport processes of athletes infected with COVID-19. This paper bridges this gap by providing recommendations to guide team physicians and athletic trainers on the utility of wearable technology for improving the well-being of athletes who may be asymptomatic, symptomatic, or tested negative but have had to quarantine due to a close exposure. We start by describing the physiologic changes that occur in athletes infected with COVID-19 with extended deconditioning from a musculoskeletal, psychological, cardiopulmonary, and thermoregulatory standpoint and review the evidence on how these athletes may safely return to play. We highlight opportunities for wearable technology to aid in the return-to-play process by offering a list of key parameters pertinent to the athlete affected by COVID-19. This paper provides the athletic community with a greater understanding of how wearable technology can be implemented in the rehabilitation process of these athletes and spurs opportunities for further innovations in wearables, digital health, and sports medicine to reduce injury burden in athletes of all ages. © The Author(s) 2023

    Wearable Technology and Analytics as a Complementary Toolkit to Optimize Workload and to Reduce Injury Burden

    Get PDF
    Wearable sensors enable the real-time and non-invasive monitoring of biomechanical, physiological, or biochemical parameters pertinent to the performance of athletes. Sports medicine researchers compile datasets involving a multitude of parameters that can often be time consuming to analyze in order to create value in an expeditious and accurate manner. Machine learning and artificial intelligence models may aid in the clinical decision-making process for sports scientists, team physicians, and athletic trainers in translating the data acquired from wearable sensors to accurately and efficiently make decisions regarding the health, safety, and performance of athletes. This narrative review discusses the application of commercial sensors utilized by sports teams today and the emergence of descriptive analytics to monitor the internal and external workload, hydration status, sleep, cardiovascular health, and return-to-sport status of athletes. This review is written for those who are interested in the application of wearable sensor data and data science to enhance performance and reduce injury burden in athletes of all ages

    Constitutivism

    Get PDF
    A brief explanation and overview of constitutivism
    corecore