9 research outputs found

    A patient-specific study investigating the relation between coronary hemodynamics and neo-intimal thickening after bifurcation stenting with a polymeric bioresorbable scaffold

    Get PDF
    We present an application of a validated reconstruction methodology for the comparison between patient-specific hemodynamics and neo-intimal thickening at nine months from the intervention. (1) Background: Coronary bifurcation stenting alters the vessel geometry, influencing the local hemodynamics. The evaluation of wall shear stress (WSS) relies on the application of computational fluid dynamics to model its distribution along the coronary tree. The endothelium actively responds to WSS, which triggers eventual cell proliferation to cover the stent struts. (2) Methods: Baseline optical coherence tomography and angiographic data were combined to reconstruct a patient-specific coronary bifurcation with an implanted bioresorbable scaffold and to simulate the hemodynamics. Results were linked with the neo-intimal thickening after nine months from the intervention. (3) Results: Blood velocity patterns were disrupted at the bifurcation due to the presence of the stent. It was observed that 55.6% of the scaffolded lumen surface was exposed to values of time-averaged WSS lower than 0.4 Pa. Follow-up images showed a luminal narrowing of 19% in the main branch. There was also a complete coverage in 99% of struts. (4) Conclusions: This approach provided valuable complementary information that might improve the clinical outcomes in this subset of coronary diseases

    Initial experience of a large, self-expanding, and fully recapturable transcatheter aortic valve: The UK & Ireland Implanters' registry.

    Get PDF
    OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation

    Derivation and Validation of a Chronic Total Coronary Occlusion Intervention Procedural Success Score From the 20,000-Patient EuroCTO Registry: The EuroCTO (CASTLE) Score

    No full text
    Objectives: The aim was to establish a contemporary scoring system to predict the outcome of chronic total occlusion coronary angioplasty. Background: Interventional treatment of chronic total coronary occlusions (CTOs) is a developing subspecialty. Predictors of technical success or failure have been derived from datasets of modest size. A robust scoring tool could facilitate case selection and inform decision making. Methods: The study analyzed data from the EuroCTO registry. This prospective database was set up in 2008 and includes >20,000 cases submitted by CTO expert operators (>50 cases/year). Derivation (n = 14,882) and validation (n = 5,745) datasets were created to develop a risk score for predicting technical failure. Results: There were 14,882 patients in the derivation dataset (with 2,356 [15.5%] failures) and 5,745 in the validation dataset (with 703 [12.2%] failures). A total of 20.2% of cases were done retrogradely, and dissection re-entry was performed in 9.3% of cases. We identified 6 predictors of technical failure, collectively forming the CASTLE score (Coronary artery bypass graft history, Age ( 6570 years), Stump anatomy [blunt or invisible], Tortuosity degree [severe or unseen], Length of occlusion [ 6520 mm], and Extent of calcification [severe]). When each parameter was assigned a value of 1, technical failure was seen to increase from 8% with a CASTLE score of 0 to 1, to 35% with a score 654. The area under the curve (AUC) was similar in both the derivation (AUC: 0.66) and validation (AUC: 0.68) datasets. Conclusions: The EuroCTO (CASTLE) score is derived from the largest database of CTO cases to date and offers a useful tool for predicting procedural outcome

    Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement

    No full text
    OBJECTIVES The aim of this study was to evaluate the predictors of left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR).BACKGROUND LVOT obstruction is a major concern with TMVR, but limited data exist regarding its predictors and impact on outcomes.METHODS Patients with pre-procedural multidetector row computed tomography (MDCT) undergoing TMVR for failed mitral bioprosthetic valves (valve-in-valve), annuloplasty rings (valve-in-ring), and mitral annular calcification (valve-in-MAC) were included in this study. Echocardiographic and procedural characteristics were recorded, and comprehensive assessment with MDCT was performed to identify the predictors of LVOT obstruction (defined as an increment of mean LVOT gradient >= 10 mm Hg from baseline). The new LVOT (neo-LVOT) area left after TMVR was estimated by embedding a virtual valve into the mitral annulus on MDCT, simulating the procedure.RESULTS Among 194 patients with pre-procedural MDCT undergoing TMVR (valve-in-valve, 107 patients; valve-in-ring, 50 patients; valve-in-MAC, 37 patients), LVOT obstruction was observed in 26 patients (13.4%), with a higher rate after valve-in-MAC than valve-in-ring and valve-in-valve (54.1% vs. 8.0% vs. 1.9%; p < 0.001). Patients with LVOT obstruction had significantly higher procedural mortality compared with those without LVOT obstruction (34.6% vs. 2.4%; p < 0.001). Receiver-operating characteristic curve analysis showed that an estimated neo-LVOT area <= 1.7 cm(2) predicted LVOT obstruction with sensitivity of 96.2% and specificity of 92.3%.CONCLUSIONS LVOT obstruction after TMVR was associated with higher procedural mortality. A small estimated neo-LVOT area was significantly associated with LVOT obstruction after TMVR and may help identify patients at high risk for LVOT obstruction. (c) 2019 by the American College of Cardiology Foundation.Cardiolog

    Transcatheter Mitral Valve Replacement for Degenerated Bioprosthetic Valves and Failed Annuloplasty Rings.

    No full text
    BACKGROUND Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. OBJECTIVES This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). METHODS From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. RESULTS A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). CONCLUSIONS The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV

    2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay

    No full text
    corecore