21 research outputs found

    The role of nesfatin and selected molecular factors in various types of endometrial cancer

    Get PDF
    Objectives: Endometrial cancers (ECs) are the most common gynaecological cancers in well developed countries. Diabetes and metabolic syndrome are among the biggest risk factors. Nesfatin-1, the adipokine derivative of NUCB2 (nucleobindin derivative 2) is linked to the clinical course of EC. Molecular factors, including mutations in MLH1 and MHS2 genes, c-MET and ARID1A are also related to prognosis in endometrial cancer. Material and methods: Using sections of paraffin-embedded preparations and immunohistochemistry, the expression of NESF1, MLH1, MSH2,c-MET and ARID1A were examined. Results: In this study on protein expression, EC tissues manifested (although insignificantly) an elevated expression of NESF-1 in type II EC. In type I EC, NESF-1 expression was significantly higher in G1 in comparison to G2 and G3 together. A significantly lower expression of MLH1 was demonstrated in type I EC. Conclusions: The most pronounced expression involved c-MET in all EC I and EC II tissues (in over 80% of cases). A tendency was detected for a high expression of NESF-1 in patients with type II EC, who also exhibited a high expression of MSH2

    Measurements of Matching and High Count Rate Performance of Multichannel ASIC for Digital X-Ray Imaging Systems

    Get PDF
    We present the measurements of matching and high count rate performance of a 64 channel readout ASIC called DEDIX for high count rate position-sensitive measurements using semiconductor detectors. The ASIC is designed in 0.35 mum CMOS process and its total area is 3900 times 5000 mum2. The DEDIX has a binary readout architecture. Each channel is built of a charge sensitive amplifier (CSA) with a pole-zero cancellation circuit, a shaper, two independent discriminators and two independent 20-bit counters. The size of the input device in CSA has been optimized for a detector capacitance in the range of 1-3 pF per strip. An equivalent noise charge of 110 el rms has been achieved for a total detector capacitance of 1 pF at the shaper peaking time of 160 ns. Internal correction DAC implemented in each channel independently ensures a low spread of discriminator effective threshold, namely 0.4 mV at one sigma level. The mean gain in the multichannel ASIC is 54 muV/el, with a good uniformity from channel-to-channel (sd/mean ap 0.8%). Low noise performance and high rate capability have been demonstrated by the measurement up to and above 1 MHz average rate of input signals

    Characterization of Seamless CdTe Photon Counting X-Ray Detector

    Get PDF
    Spectrally selective X-ray imaging provides improved material and tissue discrimination in comparison with the state-of-the-art dual energy technologies that are commonly used in medical, industrial, and security applications. Cadmium telluride (CdTe)- and cadmium zinc telluride (CdZnTe)-based line scanners and small size two-dimensional X-ray sensors are emerging to the market, but the need for large-scale panels is axiomatic. In this study, a seamless CdTe tile was developed that enables the implementation of large-sized, energy selective X-ray detector panels. The developed tile consists of a 64 x 64 pixel array (with 150 mu m pitch) with a necessary substrate, ASIC, and CdTe crystal. The performance of the constructed seamless tile was characterized by focusing on spectral resolution and stability. In addition, a simple pixel trimming method that automates the equalization of each energy selective pixel was developed and analyzed. The obtained results suggest that the proposed concept of seamless (tileable) detector structures is a feasible approach to scale up panel sizes. The seamless tile shows comparable spectral resolution and stability performance with commercial CdTe sensors. The effect of tile to tile variation, the realization of a large-scale panel, as well as the charge sharing performance were left out of the scope and are to be studied in the next phase.Peer reviewe

    Characterization of Seamless CdTe Photon Counting X-Ray Detector

    Get PDF
    Spectrally selective X-ray imaging provides improved material and tissue discrimination in comparison with the state-of-the-art dual energy technologies that are commonly used in medical, industrial, and security applications. Cadmium telluride (CdTe)- and cadmium zinc telluride (CdZnTe)-based line scanners and small size two-dimensional X-ray sensors are emerging to the market, but the need for large-scale panels is axiomatic. In this study, a seamless CdTe tile was developed that enables the implementation of large-sized, energy selective X-ray detector panels. The developed tile consists of a 64 x 64 pixel array (with 150 mu m pitch) with a necessary substrate, ASIC, and CdTe crystal. The performance of the constructed seamless tile was characterized by focusing on spectral resolution and stability. In addition, a simple pixel trimming method that automates the equalization of each energy selective pixel was developed and analyzed. The obtained results suggest that the proposed concept of seamless (tileable) detector structures is a feasible approach to scale up panel sizes. The seamless tile shows comparable spectral resolution and stability performance with commercial CdTe sensors. The effect of tile to tile variation, the realization of a large-scale panel, as well as the charge sharing performance were left out of the scope and are to be studied in the next phase.Peer reviewe

    Some harvesting system transforming energy wastes of compressed air to electricity

    Full text link
    Energy harvesting devices are self-powered systems which are associated with input ambient energy and convert such energy to electrical one. In this study, we focus on input ambient energy deriving from compressed air. Using arbitrary pneumatic machine, the compressed air after work - with its typical parameters as overpressure 6 bar or higher and variable volume flow - is exhausted to atmosphere. This generates energy losses. We have constructed some device which transforms the loss of compressed air energy to electricity. It illustrates the principle of action very well and does not perturb operation of pneumatic machines being source of energy losses

    Radiation damage of silicon strip detectors in the NA50 experiment

    Get PDF
    Abstract During operation of the multiplicity detector in the NA50 experiment the single sided AC-coupled p-on-n silicon strip detectors were exposed to charged particle fluences up to 10 14 eq n/cm 2 and ionising doses up to 20 Mrad, with a very non-uniform radiation spatial distribution. Radiation effects in the detectors observed during the '96 lead ion run as well as results of the post-run measurements are presented in this paper

    Analysis of radiation effects on silicon strip detectors in the NA50 experiment

    Get PDF
    Abstract During the operation of the Multiplicity Detector in the NA50 experiment the single sided AC-coupled p-on-n silicon strip detectors were exposed to charged particle fluences resulting in an equivalent 1 MeV neutron fluence up to 10 14 eq. n/cm 2 and a total ionising dose up to 20 Mrad, with a very non-uniform radiation spatial distribution. In this paper detailed analysis of radiation effects observed on the detectors during the 1996 lead ion run as well as results of measurements performed after the run are presented

    The silicon Multiplicity Detector for the NA50 experiment

    Get PDF
    Abstract The operation and performance of the silicon strip Multiplicity Detector in the heavy-ion experiment NA50 at CERN are presented together with a selection of physics results. The main features of the detector are high speed (50 MHz sampling frequency), high granularity (more than 13,000 strips), and good radiation resistance. The detector provided a measurement of event centrality in Pb–Pb collisions, as well as target identification and the measurement of charged particle pseudorapidity distributions as a function of centrality

    The silicon multiplicity detector for the NA50 experiment at CERN

    Get PDF
    The design, operation and performance of the silicon strip Multiplicity Detector for the heavy-ion experiment NA50 at CERN are presented. The main features of the detector are high speed (50 MHz sampling frequency), high granularity (more than 13,000 strips), and good radiation resistance. The detector provided a measurement ofevent centrality in Pb–Pb collisions, as well as target identification and the measurement ofcharged particle pseudorapidity distributions as a function of centrality. r 2002 Elsevier Science B.V. All rights reserved. PACS: 29.4

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe
    corecore