63 research outputs found
Meeting the ISTE Challenge in the Field: An Overview of the First Six Distinguished Achievement Award Winning Programs
The 2002 National Educational Technology Standards (NETS) Distinguished Achievement Awards, sponsored by the International Society for Technology in Education (ISTE), were awarded to six teacher education programs across the United States. The awards recognize institutions that exemplify successful integration of the National Educational Technology Standards for Teachers (NETS[solid dot]T) into teacher education programs. Institutions across the country completed an extensive application process to be selected one of the first six recipients of the ISTE Distinguished Achievement award. This process included online documentation that demonstrated the program\u27s implementation of the NETS[solid dot]T models and practices. This article provides a means of uniting various programs and program developers (teacher educators and instructional technologists) by looking at the most common obstacles they face in the pursuit of appropriate infusion of technology into teacher education programs and workable solutions for overcoming those obstacles
Recommended from our members
Containment and Analysis Capability Insights Gained from Drop Testing Representative Spent Nuclear Fuel Containers
The National Spent Nuclear Fuel Program (NSNFP), operating from the Idaho National Engineering and Environmental Laboratory (INEEL), developed the standardized Department of Energy (DOE) spent nuclear fuel (SNF) canister. This canister is designed to be loaded with DOE SNF (including other radioactive materials) and then be used during interim storage, during transportation to the nation’s repository, and for final disposal at the repository without having to be reopened. The canister has been fully designed and has completed significant testing that clearly demonstrates that it can safely achieve its intended design goals. During 1999, nine 457-mm diameter test canisters were fabricated at the INEEL to represent the standardized DOE SNF canister design. Various "worst case" internals were incorporated. Seven of the test canisters were 4.57 m long and weighed approximately 2721 kg, while two were 3.00 m long and weighed approximately 1360 kg and 1725 kg. Seven of the test canisters were dropped from 9 m onto an essentially unyielding flat surface and one of the test canisters was dropped from 1 m onto a 15-cm diameter puncture post. The final test canister was dropped from 61 cm onto a 50.8 mm thick vertically oriented steel plate, and then fell over to impact another 50.8 mm thick vertically oriented steel plate. This last test represented a canister dropping onto another larger container such as a repository disposal container or waste package. The 1999 drop testing was performed at Sandia National Laboratories (SNL). The nine test canisters experienced varying degrees of damage to their skirts, lifting rings, and pressure boundary components (heads and main body). However, all of the canisters were shown to have maintained their pressure boundary (through pressure testing). Four heavily damaged canisters were also shown to be leaktight via helium leak testing. Pre- and post-drop finite element (FE) analyses were also performed. The results clearly indicated that accurate predictions of canister responses to the drop tests were achieved. The results achieved for the standardized canister can also be applicable to other well-constructed containers (canisters, casks, cans, vessels, etc.) subjected to similar loads. Properly designed containers can maintain a containment system after being subjected to dynamically induced high strains and FE computer analyses can accurately predict the resulting responses
Recommended from our members
Preliminary Drop Testing Results to Validate an Analysis Methodology for Accidental Drop Events of Containers for Radioactive Materials
The National Spent Nuclear Fuel Program, operating from the Idaho National Engineering and Environmental Laboratory (INEEL), developed the standardized Department of Energy (DOE) spent nuclear fuel (SNF) canister. During the development of this canister, more than twenty drop tests were completed, evaluating high strain behavior, puncture resistance, maintenance of containment, and other canister responses. Computer analyses of these drop-test specimens/canisters employed the ABAQUS/Explicit software. A pre-drop analysis was performed for each test specimen to predict the deformed shape and resulting material straining. Typically, a postdrop analysis was also performed to better match actual test specifics (actual impact angle, test specimen material properties, etc.). The purpose for this analysis effort was to determine the capability of current analysis techniques to accurately predict the deformed shape of a standardized DOE SNF canister subjected to a defined drop event, without actually having to perform a drop test for every drop event of interest. Those analytical efforts yielded very accurate predictions for nearly all of the drop tests. However, it was noted, during one small-scale test, that the calculated deformed shape of the test specimen depended on the modeled frictional behavior as it impacted the essentially unyielding flat surface. In order to calculate the correct deformed shape, the modeled frictional behavior had to be changed to an unanticipated value. This paper will report the results of a preliminary investigation that determined the appropriate frictional modeling for a variety of impact angles. That investigation included drop testing performed at the INEEL from September 2000 to January 2001
Recommended from our members
Analytical Evaluation of Drop Tests Performed on Nine 18-Inch Diameter Standardized DOE Spent Nuclear Fuel Canisters
During fiscal year 1999, a total of nine 18-inch diameter test canisters were fabricated at the Idaho National Engineering & Environmental Laboratory (INEEL) to represent the standardized Department of Energy (DOE) Spent Nuclear Fuel (SNF) canister design. Various "worst case" internal loadings were incorporated. Seven of the test canisters were 15-foot long and weighed approximately 6000 pounds, while two were 10-foot long and weighed 3000 and 3800 pounds. Seven of the test canisters were dropped from thirty feet onto an essentially unyielding flat surface and one of the test canisters was dropped from 40-inches onto a 6-inch diameter puncture post. The final test canister was dropped from 24 inches onto a 2-inch thick vertically oriented steel plate, and then tipped over to impact another 2-inch thick vertically oriented steel plate. This last test was attempting to represent a canister dropping onto another larger container such as a repository disposal container. All drop testing was performed at Sandia National Laboratory (SNL). The nine test canisters experienced varying degrees of damage to their skirts, lifting rings, and pressure boundary components (heads and main body). However, all of the canisters were shown to have maintained their pressure boundary (through pressure testing), and the four worst damaged canisters were also shown to be leaktight (via helium leak testing performed at the INEEL). Pre-drop and post-drop test canister finite element modeling was performed at the INEEL in support of the canister drop test program. All model evaluations were performed using the ABAQUS/Explicit software. The finite element models representing the test canisters accurately (though at times, slightly conservatively) predicted the actual test canister responses during the defined drop events.This paper will discuss highlights of the drop testing program and will give detailed comparisons of analysis versus actual test results
Recommended from our members
Recent Progress on the Standardized DOE Spent Nuclear Fuel Canister
The Department of Energy (DOE) has developed a set of containers for the handling, interim storage, transportation, and disposal in the national repository of DOE spent nuclear fuel (SNF). This container design, referred to as the standardized DOE SNF canister or standardized canister, was developed by the Department's National Spent Nuclear Fuel Storage Program (NSNFP) working in conjunction with the Office of Civilian Radioactive Waste Management (OCRWM) and the DOE spent fuel sites. This canister had to have a standardized design yet be capable of accepting virtually all of the DOE SNF, be placed in a variety of storage and transportation systems, and still be acceptable to the repository. Since specific design details regarding the storage, transportation, and repository disposal of DOE SNF were not finalized, the NSNFP recognized the necessity to specify a complete DOE SNF canister design. This allowed other evaluations of canister performance and design to proceed as well as providing standardized canister users adequate information to proceed with their work. This paper is an update of a paper presented to the 1999 American Nuclear Society of Mechanical Engineers (ASME) Pressure Vessels and Piping (PVP) Conference. It discusses recent progress achieved in various areas to enhance acceptance of this canister not only by the DOE complex but also fabricators and regulatory agencies
CFD [computational fluid dynamics] And Safety Factors. Computer modeling of complex processes needs old-fashioned experiments to stay in touch with reality.
Computational fluid dynamics (CFD) is recognized as a powerful engineering tool. That is, CFD has advanced over the years to the point where it can now give us deep insight into the analysis of very complex processes. There is a danger, though, that an engineer can place too much confidence in a simulation. If a user is not careful, it is easy to believe that if you plug in the numbers, the answer comes out, and you are done. This assumption can lead to significant errors. As we discovered in the course of a study on behalf of the Department of Energy's Savannah River Site in South Carolina, CFD models fail to capture some of the large variations inherent in complex processes. These variations, or scatter, in experimental data emerge from physical tests and are inadequately captured or expressed by calculated mean values for a process. This anomaly between experiment and theory can lead to serious errors in engineering analysis and design unless a correction factor, or safety factor, is experimentally validated. For this study, blending times for the mixing of salt solutions in large storage tanks were the process of concern under investigation. This study focused on the blending processes needed to mix salt solutions to ensure homogeneity within waste tanks, where homogeneity is required to control radioactivity levels during subsequent processing. Two of the requirements for this task were to determine the minimum number of submerged, centrifugal pumps required to blend the salt mixtures in a full-scale tank in half a day or less, and to recommend reasonable blending times to achieve nearly homogeneous salt mixtures. A full-scale, low-flow pump with a total discharge flow rate of 500 to 800 gpm was recommended with two opposing 2.27-inch diameter nozzles. To make this recommendation, both experimental and CFD modeling were performed. Lab researchers found that, although CFD provided good estimates of an average blending time, experimental blending times varied significantly from the average
Weight loss in individuals with metabolic syndrome given DASH diet counseling when provided a low sodium vegetable juice: a randomized controlled trial
<p>Abstract</p> <p>Background</p> <p>Metabolic syndrome, a constellation of metabolic risk factors for type 2 diabetes and cardiovascular disease, is one of the fastest growing disease entities in the world. Weight loss is thought to be a key to improving all aspects of metabolic syndrome. Research studies have suggested benefits from diets rich in vegetables and fruits in helping individuals reach and achieve healthy weights.</p> <p>Objective</p> <p>To evaluate the effects of a ready to serve vegetable juice as part of a calorie-appropriate Dietary Approaches to Stop Hypertension (DASH) diet in an ethnically diverse population of people with Metabolic Syndrome on weight loss and their ability to meet vegetable intake recommendations, and on their clinical characteristics of metabolic syndrome (waist circumference, triglycerides, HDL, fasting blood glucose and blood pressure).</p> <p>A secondary goal was to examine the impact of the vegetable juice on associated parameters, including leptin, vascular adhesion markers, and markers of the oxidative defense system and of oxidative stress.</p> <p>Methods</p> <p>A prospective 12 week, 3 group (0, 8, or 16 fluid ounces of low sodium vegetable juice) parallel arm randomized controlled trial. Participants were requested to limit their calorie intake to 1600 kcals for women and 1800 kcals for men and were educated on the DASH diet. A total of 81 (22 men & 59 women) participants with Metabolic Syndrome were enrolled into the study. Dietary nutrient and vegetable intake, weight, height, leptin, metabolic syndrome clinical characteristics and related markers of endothelial and cardiovascular health were measured at baseline, 6-, and 12-weeks.</p> <p>Results</p> <p>There were significant group by time interactions when aggregating both groups consuming vegetable juice (8 or 16 fluid ounces daily). Those consuming juice lost more weight, consumed more Vitamin C, potassium, and dietary vegetables than individuals who were in the group that only received diet counseling (p < 0.05).</p> <p>Conclusion</p> <p>The incorporation of vegetable juice into the daily diet can be a simple and effective way to increase the number of daily vegetable servings. Data from this study also suggest the potential of using a low sodium vegetable juice in conjunction with a calorie restricted diet to aid in weight loss in overweight individuals with metabolic syndrome.</p
International genome-wide meta-analysis identifies new primary biliary cirrhosis risk loci and targetable pathogenic pathways.
Primary biliary cirrhosis (PBC) is a classical autoimmune liver disease for which effective immunomodulatory therapy is lacking. Here we perform meta-analyses of discovery data sets from genome-wide association studies of European subjects (n=2,764 cases and 10,475 controls) followed by validation genotyping in an independent cohort (n=3,716 cases and 4,261 controls). We discover and validate six previously unknown risk loci for PBC (Pcombined<5 × 10(-8)) and used pathway analysis to identify JAK-STAT/IL12/IL27 signalling and cytokine-cytokine pathways, for which relevant therapies exist
Large expert-curated database for benchmarking document similarity detection in biomedical literature search
Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe
- …