39 research outputs found

    Centrality evolution of the charged-particle pseudorapidity density over a broad pseudorapidity range in Pb-Pb collisions at root s(NN)=2.76TeV

    Get PDF
    Peer reviewe

    Optimizing the risk threshold of lymph node involvement for performing extended pelvic lymph node dissection in prostate cancer patients: a cost-effectiveness analysis

    Get PDF
    Background: Extended pelvic lymph node dissection (ePLND) may be omitted in prostate cancer (CaP) patients with a low predicted risk of lymph node involvement (LNI). The aim of the current study was to quantify the cost-effectiveness of using different risk thresholds for predicted LNI in CaP patients to inform decision making on omitting ePLND. Methods: Five different thresholds (2%, 5%, 10%, 20%, and 100%) used in practice for performing ePLND were compared using a decision analytic cohort model with the 100% threshold (i.e., no ePLND) as reference. Compared outcomes consisted of quality-adjusted life years (QALYs) and costs. Baseline characteristics for the hypothetical cohort were based on an actual Dutch patient cohort containing 925 patients who underwent ePLND with risks of LNI predicted by the Memorial Sloan Kettering Cancer Center web-calculator. The best strategy was selected based on the incremental cost effectiveness ratio when applying a willingness to pay (WTP) threshold of €20,000 per QALY gained. Probabilistic sensitivity analysis was performed with Monte Carlo simulation to assess the robustness of the results. Results: Costs and health outcomes were lowest (€4,858 and 6.04 QALYs) for the 100% threshold, and highest (€10,939 and 6.21 QALYs) for the 2% threshold, respectively. The incremental cost effectiveness ratio for the 2%, 5%, 10%, and 20% threshold compared with the first threshold above (i.e., 5%, 10%, 20%, and 100%) were €189,222/QALY, €130,689/QALY, €51,920/QALY, and €23,187/QALY respectively. Applying a WTP threshold of €20.000 the probabilities for the 2%, 5%, 10%, 20%, and 100% threshold strategies being cost-effective were 0.0%, 0.3%, 4.9%, 30.3%, and 64.5% respectively. Conclusion: Applying a WTP threshold of €20.000, completely omitting ePLND in CaP patients is cost-effective compared to other risk-based strategies. However, applying a 20% threshold for probable LNI to the Briganti 2012 nomogram or the Memorial Sloan Kettering Cancer Center web-calculator, may be a feasible alternative, in particular when higher WTP values are considered

    Clinical use of the SelectMDx urinary-biomarker test with or without mpMRI in prostate cancer diagnosis : a prospective, multicenter study in biopsy-naive men

    No full text
    Background Risk stratification in men with suspicion of prostate cancer (PCa) requires reliable diagnostic tests, not only to identify high-grade PCa, also to minimize the overdetection of low-grade PCa, and reduction of "unnecessary" prostate MRIs and biopsies. This study aimed to evaluate the SelectMDx test to detect high-grade PCa in biopsy-naive men. Subsequently, to assess combinations of SelectMDx test and multi-parametric (mp) MRI and its potential impact on patient selection for prostate biopsy. Methods This prospective multicenter diagnostic study included 599 biopsy-naive patients with prostate-specific antigen level >= 3 ng/ml. All patients underwent a SelectMDx test and mpMRI before systematic transrectal ultrasound-guided biopsy (TRUSGB). Patients with a suspicious mpMRI also had an in-bore MR-guided biopsy (MRGB). Histopathologic outcome of TRUSGB and MRGB was used as reference standard. High-grade PCa was defined as ISUP Grade Group (GG) >= 2. The primary outcome was the detection rates of low- and high-grade PCa and number of biopsies avoided in four strategies, i.e., (1) SelectMDx test-only, (2) mpMRI-only, (3) SelectMDx test followed by mpMRI when SelectMDx test was positive (conditional strategy), and (4) SelectMDx test and mpMRI in all (joint strategy). A positive SelectMDx test outcome was a risk score of >=-2.8. Decision curve analysis (DCA) was performed to assess clinical utility. Results Prevalence of high-grade PCa was 31% (183/599). Thirty-eight percent (227/599) of patients had negative SelectMDx test in whom biopsy could be avoided. Low-grade PCa was not detected in 35% (48/138) with missing 10% (18/183) high-grade PCa. Yet, mpMRI-only could avoid 49% of biopsies, not detecting 4.9% (9/183) of high-grade PCa. The conditional strategy reduces the number of mpMRIs by 38% (227/599), avoiding biopsy in 60% (357/599) and missing 13% (24/183) high-grade PCa. Low-grade PCa was not detected in 58% (80/138). DCA showed the highest net benefit for the mpMRI-only strategy, followed by the conditional strategy at-risk thresholds >10%. Conclusions SelectMDx test as a risk stratification tool for biopsy-naive men avoids unnecessary biopsies in 38%, minimizes low-grade PCa detection, and misses only 10% high-grade PCa. Yet, using mpMRI in all patients had the highest net benefit, avoiding biopsy in 49% and missing 4.9% of high-risk PCa. However, if mpMRI availability is limited or expensive, using mpMRI-only in SelectMDx test positive patients is a good alternative strategy

    Sequence variant on 8q24 confers susceptibility to urinary bladder cancer.

    No full text
    Contains fulltext : 71044.pdf (publisher's version ) (Closed access)We conducted a genome-wide SNP association study on 1,803 urinary bladder cancer (UBC) cases and 34,336 controls from Iceland and The Netherlands and follow up studies in seven additional case-control groups (2,165 cases and 3,800 controls). The strongest association was observed with allele T of rs9642880 on chromosome 8q24, 30 kb upstream of MYC (allele-specific odds ratio (OR) = 1.22; P = 9.34 x 10(-12)). Approximately 20% of individuals of European ancestry are homozygous for rs9642880[T], and their estimated risk of developing UBC is 1.49 times that of noncarriers. No association was observed between UBC and the four 8q24 variants previously associated with prostate, colorectal and breast cancers, nor did rs9642880 associate with any of these three cancers. A weaker signal, but nonetheless of genome-wide significance, was captured by rs710521[A] located near TP63 on chromosome 3q28 (allele-specific OR = 1.19; P = 1. 15 x 10(-7))

    D. Die einzelnen romanischen Sprachen und Literaturen.

    No full text

    Direct observation of the dead-cone effect in quantum chromodynamics

    No full text
    The direct measurement of the QCD dead cone in charm quark fragmentation is reported, using iterative declustering of jets tagged with a fully reconstructed charmed hadron

    Direct observation of the dead-cone effect in quantum chromodynamics

    No full text
    At particle collider experiments, elementary particle interactions with large momentum transfer produce quarks and gluons (known as partons) whose evolution is governed by the strong force, as described by the theory of quantum chromodynamics (QCD) [1]. The vacuum is not transparent to the partons and induces gluon radiation and quark pair production in a process that can be described as a parton shower [2]. Studying the pattern of the parton shower is one of the key experimental tools in understanding the properties of QCD. This pattern is expected to depend on the mass of the initiating parton, through a phenomenon known as the dead-cone effect, which predicts a suppression of the gluon spectrum emitted by a heavy quark of mass m and energy E, within a cone of angular size m/E around the emitter [3]. A direct observation of the dead-cone effect in QCD has not been possible until now, due to the challenge of reconstructing the cascading quarks and gluons from the experimentally accessible bound hadronic states. Here we show the first direct observation of the QCD dead-cone by using new iterative declustering techniques [4, 5] to reconstruct the parton shower of charm quarks. This result confirms a fundamental feature of QCD, which is derived more generally from its origin as a gauge quantum field theory. Furthermore, the measurement of a dead-cone angle constitutes the first direct experimental observation of the non-zero mass of the charm quark, which is a fundamental constant in the standard model of particle physics.The direct measurement of the QCD dead cone in charm quark fragmentation is reported, using iterative declustering of jets tagged with a fully reconstructed charmed hadron.In particle collider experiments, elementary particle interactions with large momentum transfer produce quarks and gluons (known as partons) whose evolution is governed by the strong force, as described by the theory of quantum chromodynamics (QCD). These partons subsequently emit further partons in a process that can be described as a parton shower which culminates in the formation of detectable hadrons. Studying the pattern of the parton shower is one of the key experimental tools for testing QCD. This pattern is expected to depend on the mass of the initiating parton, through a phenomenon known as the dead-cone effect, which predicts a suppression of the gluon spectrum emitted by a heavy quark of mass mQm_{\rm{Q}} and energy EE, within a cone of angular size mQm_{\rm{Q}}/EE around the emitter. Previously, a direct observation of the dead-cone effect in QCD had not been possible, owing to the challenge of reconstructing the cascading quarks and gluons from the experimentally accessible hadrons. We report the direct observation of the QCD dead cone by using new iterative declustering techniques to reconstruct the parton shower of charm quarks. This result confirms a fundamental feature of QCD. Furthermore, the measurement of a dead-cone angle constitutes a direct experimental observation of the non-zero mass of the charm quark, which is a fundamental constant in the standard model of particle physics
    corecore