4,510 research outputs found

    Evaluation of a subscale internally insulated fiber-glass propellant tank for liquid hydrogen

    Get PDF
    Subscale internally insulated fiberglass reinforced plastics, propellant tank for liquid hydroge

    Measurements of Rudder Moments on an Airplane During Flight

    Get PDF
    Tests indicated that: 1) C airplanes with two struts are extremely susceptible to aileron maneuvers, slight alterations of the aileron sufficing to compensate great unequalized moments; 2) great unequalized moments can be produced or neutralized by the unequalized alternation of the angle of attack below the outer and inner struts. Adjustment below the outer strut is the more effective of the two. 3) When a load of bombs is suspended beyond the center of the airplane, below the wings, the bombs need not be dropped simultaneously. 4) The propeller wash of a wide open engine has considerable influence on the position and operation of the elevator. The elevator is more susceptible in flight with the engine running than in gliding flight. 5) Adjustable tail planes are not advisable for D airplanes, nor for the C type, but they are, on the other hand, to be recommended for large size and giant airplanes in which the center of gravity changes during flight. 6) The aileron values obtained by wind tunnel measurements are about 10 percent too low, though otherwise applicable. For the elevator, the results of such measurements should be taken as mean values between flight with the engine running and gliding flight

    Speed measurements made by Division "A" of the airplane director

    Get PDF
    The various speeds of an airplane can only be measured in horizontal flight, since there are no means for measuring the angle of ascent or descent. The measurements must be corrected for the density of the air. This is obtained by simultaneous pressure and temperature measurements during flight. Calculation from the mean yearly values in accordance with Everling's suggestion can only be considered an approximation, since the distribution of pressure and temperature in the individual strata at different altitudes undergoes such large variations that the yearly mean gives inaccurate values. Thermographs of the present form are useless for temperature measurements of an airplane. In altitude data, the following are to be distinguished: the height above the earth, the barometric altitude, and the altitude corresponding to the yearly mean air density. Variometers are not suited for the mechanical control of high altitude flight

    Unsteady blade pressure measurements for the SR-7A propeller at cruise conditions

    Get PDF
    The unsteady blade surface pressures were measured on the SR-7A propeller. The freestream Mach no., inflow angle, and advance ratio were varied while measurements were made at nine blade stations. At a freestream Mach no. of 0.8, the data in terms of unsteady pressure coefficient vs. azimuth angle are compared to an unsteady 3-D Euler solution, yielding very encouraging results. The code predicts the shape (phase) of the waveform very well, while the magnitude is over-predicted in many cases. At tunnel Mach nos. below 0.6, an unusually large response on the suction surface at 0.15 chord and 0.88 radius was observed. The behavior of this response suggests the presence of a leading edge vortex. The midchord measuring stations on the suction surface exhibit a response that leads the forcing function while most other locations show a phase lag

    Full-scale engine tests of bulk absorber acoustic inlet treatment

    Get PDF
    Three different densities of Keviar bulk absorber fan inlet treatment were tested on a YF 102 turbofan engine. This bulk absorber material may have potential for flight application. Farfield noise measurements were made and the attenuation properties of the three treatment densities were compared. In addition, the best bulk treatment was compared to the best single degree of freedom, SDOF (honeycomb and perforated cover sheet) treatment from another investigation. Although the density was varied over a large range, (3 to 1) the effect on attenuation was small. The highest density treatment, 11.8 lb/cubic ft., had a somewhat broader attenuation bandwidth. The comparison of the best bulk and SDOF treatments showed the bulk to have a much greater attenuation bandwidth. At the design frequency both types of treatment had almost equal performance

    Comparison of inlet suppressor data with approximate theory based on cutoff ratio

    Get PDF
    Inlet suppressor far-field directivity suppression was quantitatively compared with that predicted using an approximate linear design and evaluation method based upon mode cutoff ratio. The experimental data was obtained using a series of cylindrical point-reacting inlet liners on a YF102 engine. The theoretical prediction program is based upon simplified sound propagation concepts derived from exact calculations. These indicate that all of the controlling phenomenon can be approximately correlated with mode cutoff ratio which itself is intimately related to the angles of propagation within the duct. The theory-data comparisons are intended to point out possible deficiencies in the approximate theory which may be corrected. After all theoretical refinements are made, then empirical corrections can be applied

    Acoustic, performance, and wake survey measurements of a lobed velocity-decayer nozzle installed on a quieted TF-34 turbofan engine

    Get PDF
    Results for three velocity decayer nozzle configurations are compared with those obtained with a separate flow coannular nozzle tested on the same quieted turbofan engine. Peak sideline noise, which occurred 110 degrees from the inlet, was 2 to 4 db louder than with the coannular nozzle at the same ideal effective exhaust velocity and 8 to 11 db louder at the same thrust level. The decayer nozzles produced an increase in loss equivalent to about 4 percent of the engine thrust and also increased the effective exhaust velocity of the engine. The exhaust decayed to 0.35 of its peak velocity, compared with no decay for the coannular nozzle, within 3 equivalent nozzle diameters of the exit. The peak exhaust gas temperature was 400 K lower for the decayer configuration at the same location. The increase in perceived noise level for the decayer nozzles as compared with the coannular nozzle was attributed to the increase in exhaust velocity and the shift in peak spectrum frequency produced by these nozzles

    Acoustic Mode Measurements in the Inlet of a Model Turbofan Using a Continuously Rotating Rake

    Get PDF
    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator
    corecore