3,906,579 research outputs found

    The gamma-ray burst monitor for Lobster-ISS

    Get PDF
    Lobster-ISS is an X-ray all-sky monitor experiment selected by ESA two years ago for a Phase A study (now almost completed) for a future flight (2009) aboard the Columbus Exposed Payload Facility of the International Space Station. The main instrument, based on MCP optics with Lobster-eye geometry, has an energy passband from 0.1 to 3.5 keV, an unprecedented daily sensitivity of 2x10^{-12} erg cm^{-2}s$^{-1}, and it is capable to scan, during each orbit, the entire sky with an angular resolution of 4--6 arcmin. This X-ray telescope is flanked by a Gamma Ray Burst Monitor, with the minimum requirement of recognizing true GRBs from other transient events. In this paper we describe the GRBM. In addition to the minimum requirement, the instrument proposed is capable to roughly localize GRBs which occur in the Lobster FOV (162x22.5 degrees) and to significantly extend the scientific capabilities of the main instrument for the study of GRBs and X-ray transients. The combination of the two instruments will allow an unprecedented spectral coverage (from 0.1 up to 300/700 keV) for a sensitive study of the GRB prompt emission in the passband where GRBs and X-Ray Flashes emit most of their energy. The low-energy spectral band (0.1-10 keV) is of key importance for the study of the GRB environment and the search of transient absorption and emission features from GRBs, both goals being crucial for unveiling the GRB phenomenon. The entire energy band of Lobster-ISS is not covered by either the Swift satellite or other GRB missions foreseen in the next decade.Comment: 6 pages, 4 figures. Paper presented at the COSPAR 2004 General Assembly (Paris), accepted for publication in Advances in Space Research in June 2005 and available on-line at the Journal site (http://www.sciencedirect.com/science/journal/02731177), section "Articles in press

    Antimicrobials: a global alliance for optimizing their rational use in intra-abdominal infections (AGORA)

    Get PDF
    Intra-abdominal infections (IAI) are an important cause of morbidity and are frequently associated with poor prognosis, particularly in high-risk patients. The cornerstones in the management of complicated IAIs are timely effective source control with appropriate antimicrobial therapy. Empiric antimicrobial therapy is important in the management of intra-abdominal infections and must be broad enough to cover all likely organisms because inappropriate initial antimicrobial therapy is associated with poor patient outcomes and the development of bacterial resistance. The overuse of antimicrobials is widely accepted as a major driver of some emerging infections (such as C. difficile), the selection of resistant pathogens in individual patients, and for the continued development of antimicrobial resistance globally. The growing emergence of multi-drug resistant organisms and the limited development of new agents available to counteract them have caused an impending crisis with alarming implications, especially with regards to Gram-negative bacteria. An international task force from 79 different countries has joined this project by sharing a document on the rational use of antimicrobials for patients with IAIs. The project has been termed AGORA (Antimicrobials: A Global Alliance for Optimizing their Rational Use in Intra-Abdominal Infections). The authors hope that AGORA, involving many of the world's leading experts, can actively raise awareness in health workers and can improve prescribing behavior in treating IAIs

    Direct photon elliptic flow in Pb-Pb collisions at root s(NN)=2.76 TeV

    Get PDF
    The elliptic flow of inclusive and direct photons was measured at mid-rapidity in two centrality classes 0-20% and 20-40% in Pb-Pb collisions at root s(NN) = 2.76 TeV by ALICE. Photons were detected with the highly segmented electromagnetic calorimeter PHOS and via conversions in the detector material with the e(broken vertical bar)e pairs reconstructed in the central tracking system. The results of the two methods were combined and the direct-photon elliptic flow was extracted in the transverse momentum range 0.9 < p(T) < 6.2 GeV/c. A comparison to RHIC data shows a similar magnitude of the measured direct-photon elliptic flow. Hydrodynamic and transport model calculations are systematically lower than the data, but are found to be compatible. (C) 2018 The Author. Published by Elsevier B.V.Peer reviewe

    Study of B Meson Production in p plus Pb Collisions at root s(NN)=5.02 TeV Using Exclusive Hadronic Decays

    Get PDF
    Peer reviewe

    Rebamipide Does Not Protect Against Naproxen-induced Gastric Damage: A Randomized Double-blind Controlled Trial

    Get PDF
    Rebamipide is a gastroprotective agent with promising results against gastric damage induced by non-steroidal anti-inflammatory drugs. The present study evaluated if rebamipide protects against naproxen-induced gastric damage in healthy volunteers. Changes in gastric PGE2 tissue concentration were also evaluated. Methods: After a preliminary endoscopy to rule out previous gastric macroscopic damage, twenty-four healthy volunteers of both sexes were divided into 2 groups. One group received sodium naproxen 550 mg b.i.d. plus placebo for 7 days, while the other group received sodium naproxen 550 mg b.i.d. plus rebamipide 100 mg b.i.d. At the end of treatment, a new endoscopy was performed. Gastric macroscopic damage was evaluated by the Cryer score and by the modified Lanza score. The primary outcome measure of the trial was the macroscopic damage observed in each treatment group at the end of treatment. Biopsies were collected at both endoscopies for PGE2 quantification and histopathological analysis (secondary outcomes). Tissue PGE2 was quantified by ELISA. The randomization sequence was generated using 3 blocks of 8 subjects each. Volunteers and endoscopists were blind to whether they were receiving rebamipide or placebo. Results: All recruited volunteers completed the trial. Sodium naproxen induced gastric damage in both groups. At the end of the study, median Cryer score was 4 in both groups (Difference = 0; 95% CI = -1 to 0; p = 0.728). In the placebo group, the mean tissue PGE2 concentration was 1005 +/- 129 pg/mL before treatment and 241 +/- 41 pg/mL after treatment (p < 0.001). In the rebamipide group, the mean tissue PGE2 concentration was 999 +/- 109 pg/mL before treatment, and 168 +/- 13 pg/mL after treatment (p < 0.001). There was no difference in mean tissue PGE2 between the two groups (difference = 5; 95% CI from -334.870 to 345.650; p = 0.975). No significant change was observed at the histopathological evaluation, despite the evident macroscopic damage induced by naproxen. Conclusion: Rebamipide does not protect against naproxen-induced gastric damage in healthy volunteers.16Biolab Industria Farmaceutica Ltd

    Riemann-Hilbert problem for the small dispersion limit of the KdV equation and linear overdetermined systems of Euler-Poisson-Darboux type

    Full text link
    We study the Cauchy problem for the Korteweg de Vries (KdV) equation with small dispersion and with monotonically increasing initial data using the Riemann-Hilbert (RH) approach. The solution of the Cauchy problem, in the zero dispersion limit, is obtained using the steepest descent method for oscillatory Riemann-Hilbert problems. The asymptotic solution is completely described by a scalar function \g that satisfies a scalar RH problem and a set of algebraic equations constrained by algebraic inequalities. The scalar function \g is equivalent to the solution of the Lax-Levermore maximization problem. The solution of the set of algebraic equations satisfies the Whitham equations. We show that the scalar function \g and the Lax-Levermore maximizer can be expressed as the solution of a linear overdetermined system of equations of Euler-Poisson-Darboux type. We also show that the set of algebraic equations and algebraic inequalities can be expressed in terms of the solution of a different set of linear overdetermined systems of equations of Euler-Poisson-Darboux type. Furthermore we show that the set of algebraic equations is equivalent to the classical solution of the Whitham equations expressed by the hodograph transformation.Comment: 32 pages, 1 figure, latex2

    GALEX J201337.6+092801: The lowest gravity subdwarf B pulsator

    Full text link
    We present the recent discovery of a new subdwarf B variable (sdBV), with an exceptionally low surface gravity. Our spectroscopy of J20136+0928 places it at Teff = 32100 +/- 500, log(g) = 5.15 +/- 0.10, and log(He/H) = -2.8 +/- 0.1. With a magnitude of B = 12.0, it is the second brightest V361 Hya star ever found. Photometry from three different observatories reveals a temporal spectrum with eleven clearly detected periods in the range 376 to 566 s, and at least five more close to our detection limit. These periods are unusually long for the V361 Hya class of short-period sdBV pulsators, but not unreasonable for p- and g-modes close to the radial fundamental, given its low surface gravity. Of the ~50 short period sdB pulsators known to date, only a single one has been found to have comparable spectroscopic parameters to J20136+0928. This is the enigmatic high-amplitude pulsator V338 Ser, and we conclude that J20136+0928 is the second example of this rare subclass of sdB pulsators located well above the canonical extreme horizontal branch in the HR diagram.Comment: 5 pages, accepted for publication in ApJ Letter

    Development of EM-CCD-based X-ray detector for synchrotron applications

    Get PDF
    A high speed, low noise camera system for crystallography and X-ray imaging applications is developed and successfully demonstrated. By coupling an electron-multiplying (EM)-CCD to a 3:1 fibre-optic taper and a CsI(Tl) scintillator, it was possible to detect hard X-rays. This novel approach to hard X-ray imaging takes advantage of sub-electron equivalent readout noise performance at high pixel readout frequencies of EM-CCD detectors with the increase in the imaging area that is offered through the use of a fibre-optic taper. Compared with the industry state of the art, based on CCD camera systems, a high frame rate for a full-frame readout (50 ms) and a lower readout noise (<1 electron root mean square) across a range of X-ray energies (6–18 keV) were achieved

    Ultra-high-sensitivity two-dimensional bend sensor

    Get PDF
    A multicore fibre Fabry-Perot-based strain sensor interrogated with tandem interferometry for bend measurement is described. Curvature in two dimensions is obtained by measuring the difference in strain between three co-located low finesse Fabry-Perot interferometers formed in each core of the fibre by pairs of Bragg gratings. This sensor provides a responsivity enhancement of up to 30 times that of a previously reported fibre Bragg grating based sensor. Strain resolutions of 0.6 n epsilon/Hz(1/2) above 1 Hz are demonstrated, which corresponds to a curvature resolution of similar to 0.012 km(-1)/Hz(1/2)
    corecore