57 research outputs found

    A mixed model of active geodesic contours with gradient vector flows for X-ray microtomography segmentation

    Get PDF
    Actes de la conférence "Mathématiques pour l'image" - PUOInternational audienceThe structural characterization of weathered building stones of historical monuments can be achieved with a powerfull imagering technique, X-ray microtomography. It requires however a carefull extraction of each phase constituting the sample from the raw gray-level images obtained (the segmentation process). This contribution presents an original method of segmentation of such images that combines active contour models driven by gradient vector flows with a morphological preprocessing, alternate sequential filters. Preliminary results on high resolution, structuraly complex images are presented and compared to more classical approaches

    Anatomically constrained CT image translation for heterogeneous blood vessel segmentation

    Full text link
    Anatomical structures such as blood vessels in contrast-enhanced CT (ceCT) images can be challenging to segment due to the variability in contrast medium diffusion. The combined use of ceCT and contrast-free (CT) CT images can improve the segmentation performances, but at the cost of a double radiation exposure. To limit the radiation dose, generative models could be used to synthesize one modality, instead of acquiring it. The CycleGAN approach has recently attracted particular attention because it alleviates the need for paired data that are difficult to obtain. Despite the great performances demonstrated in the literature, limitations still remain when dealing with 3D volumes generated slice by slice from unpaired datasets with different fields of view. We present an extension of CycleGAN to generate high fidelity images, with good structural consistency, in this context. We leverage anatomical constraints and automatic region of interest selection by adapting the Self-Supervised Body Regressor. These constraints enforce anatomical consistency and allow feeding anatomically-paired input images to the algorithm. Results show qualitative and quantitative improvements, compared to stateof-the-art methods, on the translation task between ceCT and CT images (and vice versa).Comment: Accepted at BMVC 202

    18-Month Effectiveness of Short-Course Antiretroviral Regimens Combined with Alternatives to Breastfeeding to Prevent HIV Mother-to-Child Transmission

    Get PDF
    OBJECTIVE: We assessed the 18-month effectiveness of short-course (sc) antiretroviral peripartum regimens combined with alternatives to prolonged breastfeeding to prevent mother-to-child transmission (MTCT) of HIV-1 in Abidjan, Côte d'Ivoire. METHODOLOGY: HIV-1 infected pregnant women received from >/=32-36 weeks of gestation scZidovudine (ZDV)+/-Lamivudine (3TC)+single-dose Nevirapine (sdNVP) at delivery within the ANRS 1201/1202 DITRAME-Plus cohort (2001-2003). Neonates received a sdNVP+7-day ZDV prophylaxis. Two infant-feeding interventions were systematically offered free of charge: formula-feeding or exclusive shortened breastfeeding with early cessation from four months. The reference group was the ANRS 049a DITRAME cohort (1994-2000) exposed to scZDV from 36 weeks, then to prolonged breastfeeding. Pediatric HIV infection was defined by a positive plasma HIV-1 RNA at any age, or if aged >/=18 months, a positive HIV-1 serology. Turnbull estimates of cumulative transmission risks (CTR) and effectiveness (HIV-free survival) were compared by exposure group using a Cox model. FINDINGS: Among 926 live-born children enrolled, 107 (11.6%) were HIV-infected at 18 months. CTRs were 22.3% (95% confidence interval[CI]:16-30%) in the 238 ZDV long-term breastfed reference group, 15.9% (CI:10-27%) in the 169 ZDV+sdNVP shortened breastfed group; 9.4% (CI:6-14%) in the 195 ZDV+sdNVP formula-fed group; 6.8% (CI:4-11%) in the 198 ZDV+3TC+sdNVP shortened breastfed group, and 5.6% (CI:2-10%) in the 126 ZDV+3TC+sdNVP formula-fed group. Each combination had a significantly higher effectiveness than the ZDV long-term breastfed group except for ZDV+sdNVP shortened breastfed children, ranging from 51% (CI:20-70%) for ZDV+sdNVP formula fed children to 63% (CI:40-80%) for ZDV+3TC+NVPsd shortened breastfed children, after adjustment for maternal eligibility for antiretroviral therapy (ART), home delivery and low birth-weight. Substantial MTCT risk reductions are reachable in Africa, even in short-term breastfed children. The two sc antiretroviral combinations associated to any of the two infant feeding interventions, formula-feeding and shortened breastfeeding, reduce significantly MTCT with long-term benefit until age 18 months and without increasing mortality

    Fast strain mapping in abdominal aortic aneurysm wall reveals heterogeneous patterns

    Get PDF
    Abdominal aortic aneurysm patients are regularly monitored to assess aneurysm development and risk of rupture. A preventive surgical procedure is recommended when the maximum aortic antero-posterior diameter, periodically assessed on two-dimensional abdominal ultrasound scans, reaches 5.5 mm. Although the maximum diameter criterion has limited ability to predict aneurysm rupture, no clinically relevant tool that could complement the current guidelines has emerged so far. In vivo cyclic strains in the aneurysm wall are related to the wall response to blood pressure pulse, and therefore, they can be linked to wall mechanical properties, which in turn contribute to determining the risk of rupture. This work aimed to enable biomechanical estimations in the aneurysm wall by providing a fast and semi-automatic method to post-process dynamic clinical ultrasound sequences and by mapping the cross-sectional strains on the B-mode image. Specifically, the Sparse Demons algorithm was employed to track the wall motion throughout multiple cardiac cycles. Then, the cyclic strains were mapped by means of radial basis function interpolation and differentiation. We applied our method to two-dimensional sequences from eight patients. The automatic part of the analysis took under 1.5 min per cardiac cycle. The tracking method was validated against simulated ultrasound sequences, and a maximum root mean square error of 0.22 mm was found. The strain was calculated both with our method and with the established finite-element method, and a very good agreement was found, with mean differences of one order of magnitude smaller than the image spatial resolution. Most patients exhibited a strain pattern that suggests interaction with the spine. To conclude, our method is a promising tool for investigating abdominal aortic aneurysm wall biomechanics as it can provide a fast and accurate measurement of the cyclic wall strains from clinical ultrasound sequences

    Fabrication of deformable patient-specific AAA models by material casting techniques

    Get PDF
    BackgroundAbdominal Aortic Aneurysm (AAA) is a balloon-like dilatation that can be life-threatening if not treated. Fabricating patient-specific AAA models can be beneficial for in-vitro investigations of hemodynamics, as well as for pre-surgical planning and training, testing the effectiveness of different interventions, or developing new surgical procedures. The current direct additive manufacturing techniques cannot simultaneously ensure the flexibility and transparency of models required by some applications. Therefore, casting techniques are presented to overcome these limitations and make the manufactured models suitable for in-vitro hemodynamic investigations, such as particle image velocimetry (PIV) measurements or medical imaging.MethodsTwo complex patient-specific AAA geometries were considered, and the related 3D models were fabricated through material casting. In particular, two casting approaches, i.e. lost molds and lost core casting, were investigated and tested to manufacture the deformable AAA models. The manufactured models were acquired by magnetic resonance, computed tomography (CT), ultrasound imaging, and PIV. In particular, CT scans were segmented to generate a volumetric reconstruction for each manufactured model that was compared to a reference model to assess the accuracy of the manufacturing process.ResultsBoth lost molds and lost core casting techniques were successful in the manufacturing of the models. The lost molds casting allowed a high-level surface finish in the final 3D model. In this first case, the average signed distance between the manufactured model and the reference was (−0.2±0.2) mm. However, this approach was more expensive and time-consuming. On the other hand, the lost core casting was more affordable and allowed the reuse of the external molds to fabricate multiple copies of the same AAA model. In this second case, the average signed distance between the manufactured model and the reference was (0.1±0.6) mm. However, the final model’s surface finish quality was poorer compared to the model obtained by lost molds casting as the sealing of the outer molds was not as firm as the other casting technique.ConclusionsBoth lost molds and lost core casting techniques can be used for manufacturing patient-specific deformable AAA models suitable for hemodynamic investigations, including medical imaging and PIV

    Risk factors for virological failure and subtherapeutic antiretroviral drug concentrations in HIV-positive adults treated in rural northwestern Uganda

    Get PDF
    ABSTRACT: BACKGROUND: Little is known about immunovirological treatment outcomes and adherence in HIV/AIDS patients on antiretroviral therapy (ART) treated using a simplified management approach in rural areas of developing countries, or about the main factors influencing those outcomes in clinical practice. METHODS: Cross-sectional immunovirological, pharmacological, and adherence outcomes were evaluated in all patients alive and on fixed-dose ART combinations for 24 months, and in a random sample of those treated for 12 months. Risk factors for virological failure (>1,000 copies/mL) and subtherapeutic antiretroviral (ARV) concentrations were investigated with multiple logistic regression. RESULTS: At 12 and 24 months of ART, 72% (n=701) and 70% (n=369) of patients, respectively, were alive and in care. About 8% and 38% of patients, respectively, were diagnosed with immunological failure; and 75% and 72% of patients, respectively, had undetectable HIV RNA (<400 copies/mL). Risk factors for virological failure (>1,000 copies/mL) were poor adherence, tuberculosis diagnosed after ART initiation, subtherapeutic NNRTI concentrations, general clinical symptoms, and lower weight than at baseline. About 14% of patients had low ARV plasma concentrations. Digestive symptoms and poor adherence to ART were risk factors for low ARV plasma concentrations. CONCLUSIONS: Efforts to improve both access to care and patient management to achieve better immunological and virological outcomes on ART are necessary to maximize the duration of first-line therapy

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe

    Measuring the maximum diameter of native abdominal aortic aneurysms: review and critical analysis.

    Get PDF
    International audienceOBJECTIVES: Maximum diameter is a determinant parameter for the clinical management of asymptomatic abdominal aortic aneurysm (AAA). However, its measurement is not standardised. We review the different methods used to measure AAA maximum diameter, with ultrasound (US) or computed tomography (CT). METHODS: A review of maximum diameter measurement methods with US and CT was performed, focussing on screening, surveillance before repair and decision for intervention. Diameter measurement methodology was described according to four parameters: plane of acquisition, axis of measurement, position of callipers and selected diameter. A quality score to evaluate methodology descriptions was defined (plane, axis, callipers placement and selected diameter), ranging from 0 (worst) to 4 (best). RESULTS: Review showed a wide range of definitions and practices. The mean value of the quality score was 2.52 in screening studies, 1.66 in guidelines for screening, 2.81 in follow-up studies and 1.63 in studies describing decision for intervention. CONCLUSION: To improve the efficiency of AAA management (in screening programmes, follow-up and decision for intervention), and enable comparison between future studies, a standardised methodology for AAA maximum diameter measurement is necessary. Until such a consensus is reached, publications should at least clearly report the method of measurement
    corecore