34 research outputs found

    Rationale and design of EXPLORE: a randomized, prospective, multicenter trial investigating the impact of recanalization of a chronic total occlusion on left ventricular function in patients after primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the setting of primary percutaneous coronary intervention, patients with a chronic total occlusion in a non-infarct related artery were recently identified as a high-risk subgroup. It is unclear whether ST-elevation myocardial infarction patients with a chronic total occlusion in a non-infarct related artery should undergo additional percutaneous coronary intervention of the chronic total occlusion on top of optimal medical therapy shortly after primary percutaneous coronary intervention. Possible beneficial effects include reduction in adverse left ventricular remodeling and preservation of global left ventricular function and improved clinical outcome during future coronary events.</p> <p>Methods/Design</p> <p>The Evaluating Xience V and left ventricular function in Percutaneous coronary intervention on occLusiOns afteR ST-Elevation myocardial infarction (EXPLORE) trial is a randomized, prospective, multicenter, two-arm trial with blinded evaluation of endpoints. Three hundred patients after primary percutaneous coronary intervention for ST-elevation myocardial infarction with a chronic total occlusion in a non-infarct related artery are randomized to either elective percutaneous coronary intervention of the chronic total occlusion within seven days or standard medical treatment. When assigned to the invasive arm, an everolimus-eluting coronary stent is used. Primary endpoints are left ventricular ejection fraction and left ventricular end-diastolic volume assessed by cardiac Magnetic Resonance Imaging at four months. Clinical follow-up will continue until five years.</p> <p>Discussion</p> <p>The ongoing EXPLORE trial is the first randomized clinical trial powered to investigate whether recanalization of a chronic total occlusion in a non-infarct related artery after primary percutaneous coronary intervention for ST-elevation myocardial infarction results in a better preserved residual left ventricular ejection fraction, reduced end-diastolic volume and enhanced clinical outcome.</p> <p>Trial registration</p> <p>trialregister.nl NTR1108.</p

    Clinical and Organizational Factors Related to the Reduction of Mechanical Restraint Application in an Acute Ward: An 8-Year Retrospective Analysis

    Get PDF
    Background: The purpose of this study was to describe the frequency of mechanical restraint use in an acute psychiatric ward and to analyze which variables may have significantly influenced the use of this procedure. Methods: This retrospective study was conducted in the Servizio Psichiatrico di Diagnosi e Cura (SPDC) of Modena Centro. The following variables of our sample, represented by all restrained patients admitted from 1-1-2005 to 31-12-2012, were analyzed: age, gender, nationality, psychiatric diagnoses, organic comorbidity, state and duration of admission, motivation and duration of restraints, nursing shift and hospitalization day of restraint, number of patients admitted at the time of restraint and institutional changes during the observation period. The above variables were statistically compared with those of all other non-restrained patients admitted to our ward in the same period. Results: Mechanical restraints were primarily used as a safety procedure to manage aggressive behavior of male patients, during the first days of hospitalization and night shifts. Neurocognitive disorders, organic comorbidity, compulsory state and long duration of admission were statistically significantly related to the increase of restraint use (p<.001, multivariate logistic regression). Institutional changes, especially more restricted guidelines concerning restraint application, were statistically significantly related to restraint use reduction (p<.001, chi2 test, multivariate logistic regression). Conclusion: The data obtained highlight that mechanical restraint use was influenced not only by clinical factors, but mainly by staff and policy factors, which have permitted a gradual but significant reduction in the use of this procedure through a multidimensional approach

    Localization and broadband follow-up of the gravitational-wave transient GW150914

    Get PDF
    A gravitational-wave (GW) transient was identified in data recorded by the Advanced Laser Interferometer Gravitational-wave Observatory (LIGO) detectors on 2015 September 14. The event, initially designated G184098 and later given the name GW150914, is described in detail elsewhere. By prior arrangement, preliminary estimates of the time, significance, and sky location of the event were shared with 63 teams of observers covering radio, optical, near-infrared, X-ray, and gamma-ray wavelengths with ground- and space-based facilities. In this Letter we describe the low-latency analysis of the GW data and present the sky localization of the first observed compact binary merger. We summarize the follow-up observations reported by 25 teams via private Gamma-ray Coordinates Network circulars, giving an overview of the participating facilities, the GW sky localization coverage, the timeline, and depth of the observations. As this event turned out to be a binary black hole merger, there is little expectation of a detectable electromagnetic (EM) signature. Nevertheless, this first broadband campaign to search for a counterpart of an Advanced LIGO source represents a milestone and highlights the broad capabilities of the transient astronomy community and the observing strategies that have been developed to pursue neutron star binary merger events. Detailed investigations of the EM data and results of the EM follow-up campaign are being disseminated in papers by the individual teams

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    First Measurement of the Hubble Constant from a Dark Standard Siren using the Dark Energy Survey Galaxies and the LIGO/Virgo Binary-Black-hole Merger GW170814

    Get PDF
    We present a multi-messenger measurement of the Hubble constant H 0 using the binary–black-hole merger GW170814 as a standard siren, combined with a photometric redshift catalog from the Dark Energy Survey (DES). The luminosity distance is obtained from the gravitational wave signal detected by the Laser Interferometer Gravitational-Wave Observatory (LIGO)/Virgo Collaboration (LVC) on 2017 August 14, and the redshift information is provided by the DES Year 3 data. Black hole mergers such as GW170814 are expected to lack bright electromagnetic emission to uniquely identify their host galaxies and build an object-by-object Hubble diagram. However, they are suitable for a statistical measurement, provided that a galaxy catalog of adequate depth and redshift completion is available. Here we present the first Hubble parameter measurement using a black hole merger. Our analysis results in H0=75−32+40 km s−1 Mpc−1{H}_{0}={75}_{-32}^{+40}\,\mathrm{km}\,{{\rm{s}}}^{-1}\,{\mathrm{Mpc}}^{-1}, which is consistent with both SN Ia and cosmic microwave background measurements of the Hubble constant. The quoted 68% credible region comprises 60% of the uniform prior range [20, 140] km s−1 Mpc−1, and it depends on the assumed prior range. If we take a broader prior of [10, 220] km s−1 Mpc−1, we find {H}_{0 {78}_{-24}^{+96}\,\mathrm{km}\,{{\rm{s}}}^{-1}\,{\mathrm{Mpc}}^{-1} (57% of the prior range). Although a weak constraint on the Hubble constant from a single event is expected using the dark siren method, a multifold increase in the LVC event rate is anticipated in the coming years and combinations of many sirens will lead to improved constraints on H 0

    Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total Occlusions The PRISON IV Trial

    No full text
    OBJECTIVES: The aim of this study was to investigate the efficacy and safety of the hybrid ultrathin-strut sirolimus-eluting stent (SES) with biodegradable polymer compared with the thin-strut everolimus-eluting stent (EES) with durable polymer in successfully recanalized chronic total occlusions (CTOs). BACKGROUND: The introduction of drug-eluting stents revolutionized the treatment of CTOs. However, limited data are available on new-generation drug-eluting stents with biodegradable polymer in CTOs. METHODS: In this multicenter trial, patients were randomized, after successful CTO recanalization, to either SES or EES. The primary noninferiority endpoint was in-segment late lumen loss (noninferiority margin 0.2 mm). Secondary endpoints included in-stent late lumen loss and clinical endpoints. RESULTS: Overall, 330 patients were included. At 9 months, angiography was available in 281 patients (85%). Duration of occlusion ≄3 months was 92.5%, with mean stent length of 52.4 ± 28.1 mm versus 52.3 ± 26.5 mm in the SES and EES groups. The primary noninferiority endpoint, in-segment late lumen loss, was not met for SES versus EES (0.13 ± 0.63 mm vs. 0.02 ± 0.47 mm; p = 0.08, 2-sided; difference 0.11 mm; 95% confidence interval: -0.01 to 0.25 mm; pnoninferiority = 0.11, 1-sided). In-stent late lumen loss was comparable between SES and EES (0.12 ± 0.59 mm vs. 0.07 ± 0.46 mm; p = 0.52). The incidence of in-stent and in-segment binary restenosis was significantly higher with SES compared with EES (8.0% vs. 2.1%; p = 0.028), with comparable rates of reocclusions (2.2% vs. 1.4%; p = 0.68). Clinically indicated target lesion and target vessel revascularization (9.2% vs. 4.0% [p = 0.08] and 9.2% vs. 6.0% [p = 0.33]), target vessel failure (9.9% vs. 6.6%; p = 0.35), and definite or probable stent thrombosis (0.7% vs. 0.7%; p = 1.00) were comparable between the SES and EES groups. CONCLUSIONS: This randomized trial failed to show noninferiority of hybrid SES relative to EES in terms of in-segment late lumen loss in successfully recanalized CTOs. Furthermore, a statistically significantly higher rate of binary restenosis was found with SES.publisher: Elsevier articletitle: Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total Occlusions journaltitle: JACC: Cardiovascular Interventions articlelink: http://dx.doi.org/10.1016/j.jcin.2016.10.017 content_type: article copyright: © 2017 by the American College of Cardiology Foundation. Published by Elsevier.status: publishe
    corecore