9 research outputs found

    Real-time quantification of microRNAs by stem–loop RT–PCR

    Get PDF
    A novel microRNA (miRNA) quantification method has been developed using stem–loop RT followed by TaqMan PCR analysis. Stem–loop RT primers are better than conventional ones in terms of RT efficiency and specificity. TaqMan miRNA assays are specific for mature miRNAs and discriminate among related miRNAs that differ by as little as one nucleotide. Furthermore, they are not affected by genomic DNA contamination. Precise quantification is achieved routinely with as little as 25 pg of total RNA for most miRNAs. In fact, the high sensitivity, specificity and precision of this method allows for direct analysis of a single cell without nucleic acid purification. Like standard TaqMan gene expression assays, TaqMan miRNA assays exhibit a dynamic range of seven orders of magnitude. Quantification of five miRNAs in seven mouse tissues showed variation from less than 10 to more than 30 000 copies per cell. This method enables fast, accurate and sensitive miRNA expression profiling and can identify and monitor potential biomarkers specific to tissues or diseases. Stem–loop RT–PCR can be used for the quantification of other small RNA molecules such as short interfering RNAs (siRNAs). Furthermore, the concept of stem–loop RT primer design could be applied in small RNA cloning and multiplex assays for better specificity and efficiency

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Specificity of TaqMan miRNA assays between stem–loop and linear RT primers

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Real-time quantification of microRNAs by stem–loop RT–PCR"</p><p>Nucleic Acids Research 2005;33(20):e179-e179.</p><p>Published online 27 Nov 2005</p><p>PMCID:PMC1292995.</p><p>© The Author 2005. Published by Oxford University Press. All rights reserved</p> Mature let-7a-specific assay was tested against let-7a, let-7e and pri-miR precursor let-7a-3. Δ represents the difference between two targets or methods. A total of 1.5 × 10 copies of synthetic targets were added to each RT reaction

    Scaffolding polymeric biomaterials: Are naturally occurring biological macromolecules more appropriate for tissue engineering?

    No full text

    Recent progress in fundamental understanding of halide perovskite semiconductors

    No full text
    corecore