2,267 research outputs found

    Laboratory testing in patients treated with direct oral anticoagulants: a practical guide for clinicians

    Get PDF
    Click to hear Dr Baglin's perspective on the role of the laboratory in treatment with new oral anticoagulants SUMMARY: One of the key benefits of the direct oral anticoagulants (DOACs) is that they do not require routine laboratory monitoring. Nevertheless, assessment of DOAC exposure and anticoagulant effects may become useful in various clinical scenarios. The five approved DOACs (apixaban, betrixaban, dabigatran etexilate, edoxaban and rivaroxaban) have different characteristics impacting assay selection and the interpretation of results. This article provides an updated overview on (i) which test to use (and their advantages and limitations), (ii) when to assay DOAC levels, (iii) how to interpret the results relating to bleeding risk, emergency situations and perioperative management, and (iv) what is the impact of DOACs on routine and specialized coagulation assays. Assays for anti-Xa or anti-IIa activity are the preferred methods when quantitative information is useful, although the situations in which to test for DOAC levels are still debated. Different reagent sensitivities and variabilities in laboratory calibrations impact assay results. International calibration standards for all specific tests for each DOAC are needed to reduce the inter-laboratory variability and allow inter-study comparisons. The impact of the DOACs on hemostasis testing may cause false-positive or false-negative results; however, these can be minimized by using specific assays and collecting blood samples at trough concentrations. Finally, prospective clinical trials are needed to validate the safety and efficacy of proposed laboratory thresholds in relation to clinical decisions. We offer recommendations on the tests to use for measuring DOACs and practical guidance on laboratory testing to help patient management and avoid diagnostic errors. ispartof: Journal of Thrombosis and Haemostasis vol:16 issue:2 pages:209-219 ispartof: location:England status: publishe

    D-dimer: Preanalytical, analytical, postanalytical variables, and clinical applications

    Get PDF
    D-dimer is a soluble fibrin degradation product deriving from the plasmin-mediated degradation of cross-linked fibrin. D-dimer can hence be considered a biomarker of activation of coagulation and fibrinolysis, and it is routinely used for ruling out venous thromboembolism (VTE). D-dimer is increasingly used to assess the risk of VTE recurrence and to help define the optimal duration of anticoagulation treatment in patients with VTE, for diagnosing disseminated intravascular coagulation, and for screening medical patients at increased risk of VTE. This review is aimed at (1) revising the definition of D-dimer; (2) discussing preanalytical variables affecting the measurement of D-dimer; (3) reviewing and comparing assay performance and some postanalytical variables (e.g. different units and age-adjusted cutoffs); and (4) discussing the use of D-dimer measurement across different clinical settings

    Management of the thrombotic risk associated with COVID-19:guidance for the hemostasis laboratory

    Get PDF
    Coronavirus disease 2019 (COVID-19) is associated with extreme inflammatory response, disordered hemostasis and high thrombotic risk. A high incidence of thromboembolic events has been reported despite thromboprophylaxis, raising the question of a more effective anticoagulation. First-line hemostasis tests such as activated partial thromboplastin time, prothrombin time, fibrinogen and D-dimers are proposed for assessing thrombotic risk and monitoring hemostasis, but are vulnerable to many drawbacks affecting their reliability and clinical relevance. Specialized hemostasis-related tests (soluble fibrin complexes, tests assessing fibrinolytic capacity, viscoelastic tests, thrombin generation) may have an interest to assess the thrombotic risk associated with COVID-19. Another challenge for the hemostasis laboratory is the monitoring of heparin treatment, especially unfractionated heparin in the setting of an extreme inflammatory response. This review aimed at evaluating the role of hemostasis tests in the management of COVID-19 and discussing their main limitations

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+μ+νW^+ \rightarrow \mu^+\nu and WμνW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Search for chargino-neutralino production with mass splittings near the electroweak scale in three-lepton final states in √s=13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for supersymmetry through the pair production of electroweakinos with mass splittings near the electroweak scale and decaying via on-shell W and Z bosons is presented for a three-lepton final state. The analyzed proton-proton collision data taken at a center-of-mass energy of √s=13  TeV were collected between 2015 and 2018 by the ATLAS experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 139  fb−1. A search, emulating the recursive jigsaw reconstruction technique with easily reproducible laboratory-frame variables, is performed. The two excesses observed in the 2015–2016 data recursive jigsaw analysis in the low-mass three-lepton phase space are reproduced. Results with the full data set are in agreement with the Standard Model expectations. They are interpreted to set exclusion limits at the 95% confidence level on simplified models of chargino-neutralino pair production for masses up to 345 GeV

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Powder Compaction: Compression Properties of Cellulose Ethers

    Get PDF
    Effective development of matrix tablets requires a comprehensive understanding of different raw material attributes and their impact on process parameters. Cellulose ethers (CE) are the most commonly used pharmaceutical excipients in the fabrication of hydrophilic matrices. The innate good compression and binding properties of CE enable matrices to be prepared using economical direct compression (DC) techniques. However, DC is sensitive to raw material attributes, thus, impacting the compaction process. This article critically reviews prior knowledge on the mechanism of powder compaction and the compression properties of cellulose ethers, giving timely insight into new developments in this field

    Rivaroxaban:Xarelto® - Recommendations for pharmacists

    Get PDF
    Rivaroxaban is one of the new oral anticoagulants (NOACs) (recommended as reference treatments when a long-term anticoagulation is needed). It has many potential advantages in comparison with Vitamin K Antagonists (VKA). It has a predictable anticoagulant effect and does not theoretically require biological monitoring. It is also characterized by less food and drug interactions. However, due to major risks associated with over- and under-dosage, its optimal use in patients should be carefully followed by health care professionals. The aim of this article is to provide recommendations for pharmacists on the practical use of Xarelto® in its different approved indications. This document is adapted from the practical user guide of rivaroxaban which was developed by an independent group of Belgian experts in the field of thrombosis and haemostasis

    EVpedia: a community web portal for extracellular vesicles research

    Get PDF
    Motivation: Extracellular vesicles (EVs) are spherical bilayered proteolipids, harboring various bioactive molecules. Due to the complexity of the vesicular nomenclatures and components, online searches for EV-related publications and vesicular components are currently challenging. Results: We present an improved version of EVpedia, a public database for EVs research. This community web portal contains a database of publications and vesicular components, identification of orthologous vesicular components, bioinformatic tools and a personalized function. EVpedia includes 6879 publications, 172 080 vesicular components from 263 high-throughput datasets, and has been accessed more than 65 000 times from more than 750 cities. In addition, about 350 members from 73 international research groups have participated in developing EVpedia. This free web-based database might serve as a useful resource to stimulate the emerging field of EV research.X1110478Ysciescopu

    Search for high-mass diboson resonances with boson-tagged jets in proton-proton collisions at √s=8 TeV with the ATLAS detector

    Get PDF
    A search is performed for narrow resonances decaying into WW, WZ, or ZZ boson pairs using 20.3 fb−1 of proton-proton collision data at a centre-of-mass energy of √s=8 TeV recorded with the ATLAS detector at the Large Hadron Collider. Diboson resonances with masses in the range from 1.3 to 3.0 TeV are sought after using the invariant mass distribution of dijets where both jets are tagged as a boson jet, compatible with a highly boosted W or Z boson decaying to quarks, using jet mass and substructure properties. The largest deviation from a smoothly falling background in the observed dijet invariant mass distribution occurs around 2 TeV in the WZ channel, with a global significance of 2.5 standard deviations. Exclusion limits at the 95% confidence level are set on the production cross section times branching ratio for the WZ final state of a new heavy gauge boson, W′, and for the WW and ZZ final states of Kaluza-Klein excitations of the graviton in a bulk Randall-Sundrum model, as a function of the resonance mass. W′ bosons with couplings predicted by the extended gauge model in the mass range from 1.3 to 1.5 TeV are excluded at 95% confidence level
    corecore