117 research outputs found

    Diseño de una plataforma de monitorización y análisis de datos para cicladores de baterías comerciales

    Get PDF
    Se ha diseñado una plataforma flexible capaz de llevar a cabo experimentos en cicladores de baterías comerciales, almacenar los datos de dichos experimentos y posteriormente visualizar los resultados a través de una interfaz, entre otra serie de funcionalidades. Debido a la situación actual originada por el COVID-19, se ha desarrollado y probado la aplicación con un ciclador virtual.<br /

    Modulation of the substrate specificity of the kinase PDK1 by distinct conformations of the full-length protein

    Get PDF
    The activation of at least 23 different mammalian kinases requires the phosphorylation of their hydrophobic motifs by the kinase PDK1. A linker connects the phosphoinositide-binding PH domain to the catalytic domain, which contains a docking site for substrates called the PIF pocket. Here, we used a chemical biology approach to show that PDK1 existed in equilibrium between at least three distinct conformations with differing substrate specificities. The inositol polyphosphate derivative HYG8 bound to the PH domain and disrupted PDK1 dimerization by stabilizing a monomeric conformation in which the PH domain associated with the catalytic domain and the PIF pocket was accessible. In the absence of lipids, HYG8 potently inhibited the phosphorylation of Akt (also termed PKB) but did not affect the intrinsic activity of PDK1 or the phosphorylation of SGK, which requires docking to the PIF pocket. In contrast, the small molecule valsartan bound to the PIF pocket and stabilized a second distinct monomeric conformation. Our study reveals dynamic conformations of full-length PDK1 in which the location of the linker and the PH domain relative to the catalytic domain determines the selective phosphorylation of PDK1 substrates. The study further suggests new approaches for the design of drugs to selectively modulate signaling downstream of PDK1

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Multicentre, randomised, single-blind, parallel group trial to compare the effectiveness of a Holter for Parkinson's symptoms against other clinical monitoring methods: study protocol

    Get PDF
    Introduction In recent years, multiple studies have aimed to develop and validate portable technological devices capable of monitoring the motor complications of Parkinson's disease patients (Parkinson's Holter). The effectiveness of these monitoring devices for improving clinical control is not known. Methods and analysis This is a single-blind, cluster-randomised controlled clinical trial. Neurologists from Spanish health centres will be randomly assigned to one of three study arms (1:1:1): (a) therapeutic adjustment using information from a Parkinson?s Holter that will be worn by their patients for 7 days, (b) therapeutic adjustment using information from a diary of motor fluctuations that will be completed by their patients for 7 days and (c) therapeutic adjustment using clinical information collected during consultation. It is expected that 162 consecutive patients will be included over a period of 6 months. The primary outcome is the efficiency of the Parkinson?s Holter compared with traditional clinical practice in terms of Off time reduction with respect to the baseline (recorded through a diary of motor fluctuations, which will be completed by all patients). As secondary outcomes, changes in variables related to other motor complications (dyskinesia and freezing of gait), quality of life, autonomy in activities of daily living, adherence to the monitoring system and number of doctor?patient contacts will be analysed. The noninferiority of the Parkinson's Holter against the diary of motor fluctuations in terms of Off time reduction will be studied as the exploratory objective. Ethics and dissemination approval for this study has been obtained from the Hospital Universitari de Bellvitge Ethics Committee. The results of this study will inform the practical utility of the objective information provided by a Parkinson's Holter and, therefore, the convenience of adopting this technology in clinical practice and in future clinical trials. We expect public dissemination of the results in 2022.Funding This work is supported by AbbVie S.L.U, the Instituto de Salud Carlos III [DTS17/00195] and the European Fund for Regional Development, 'A way to make Europe'

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Use of anticoagulants and antiplatelet agents in stable outpatients with coronary artery disease and atrial fibrillation. International CLARIFY registry

    Get PDF

    PENSAMIENTO CRÍTICO EN LA INVESTIGACIÓN CIENTÍFICA Y ACADÉMICA COLECCIÓN CIENTÍFICA EDUCACIÓN, EMPRESA Y SOCIEDAD

    Get PDF
    PENSAMIENTO CRÍTICO EN LA INVESTIGACIÓN CIENTÍFICA Y ACADÉMICA COLECCIÓN CIENTÍFICA EDUCACIÓN, EMPRESA Y SOCIEDAD Primera Edición 2023 Vol. 21 Editorial EIDEC Sello Editorial EIDEC (978-958-53018) NIT 900583173-1 ISBN: 978-628-95884-1-5 Formato: Digital PDF (Portable Document Format) DOI: https://doi.org/10.34893/e1150-3660-8721-s Publicación: Colombia Fecha Publicación: 13/09/2023 Coordinación Editorial Escuela Internacional de Negocios y Desarrollo Empresarial de Colombia – EIDEC Centro de Investigación Científica, Empresarial y Tecnológica de Colombia – CEINCET Red de Investigación en Educación, Empresa y Sociedad – REDIEES Revisión y pares evaluadores Centro de Investigación Científica, Empresarial y Tecnológica de Colombia – CEINCET Red de Investigación en Educación, Empresa y Sociedad – REDIEE
    corecore