75 research outputs found

    The Electronics and Data Acquisition System of the DarkSide Dark Matter Search

    Full text link
    It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions

    Equilibrium configurations of two charged masses in General Relativity

    Get PDF
    An asymptotically flat static solution of Einstein-Maxwell equations which describes the field of two non-extreme Reissner - Nordstr\"om sources in equilibrium is presented. It is expressed in terms of physical parameters of the sources (their masses, charges and separating distance). Very simple analytical forms were found for the solution as well as for the equilibrium condition which guarantees the absence of any struts on the symmetry axis. This condition shows that the equilibrium is not possible for two black holes or for two naked singularities. However, in the case when one of the sources is a black hole and another one is a naked singularity, the equilibrium is possible at some distance separating the sources. It is interesting that for appropriately chosen parameters even a Schwarzschild black hole together with a naked singularity can be "suspended" freely in the superposition of their fields.Comment: 4 pages; accepted for publication in Phys. Rev.

    Locating sex-specific evidence on clinical questions in MEDLINE: a search filter for use on OvidSP™

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many recently published clinical studies report sex-specific data. This information may help to improve clinical decision-making for both sexes, but it is not easily accessible in MEDLINE. The aim of this project was to develop and validate a search filter that would facilitate the retrieval of studies reporting high quality sex-specific data on clinical questions.</p> <p>Methods</p> <p>A filter was developed by screening titles, abstracts and Medical Subject Headings (MeSH) in a set of 80 high quality and relevant papers, 75 of which were identified through a review of clinical guidelines and five through other means. The filter, for use on OvidSP™, consists of nine command lines for searching free text words in the title, abstract and MeSH of a paper. It was able to identify 74/80 (92.5%) of the articles from which it was derived. The filter was evaluated in a set of 622 recently published original studies on Alzheimer's disease and on asthma. It was validated against a reference of 98 studies from this set, which provided high quality, clinically relevant, sex-specific evidence. Recall and precision were used as performance measures.</p> <p>Results</p> <p>The filter demonstrated 81/98 (83%) recall and 81/125 (65%) precision in retrieving relevant articles on Alzheimer's disease and on asthma. In comparison, only 30/98 (31%) recall would have been achieved if sex-specific MeSH terms only had been used.</p> <p>Conclusion</p> <p>This sex-specific search filter performs well in retrieving relevant papers, while its precision rate is good. It performs better than a search with sex-specific MeSH. The filter can be useful to anyone seeking sex-specific clinical evidence (e.g., guideline organizations, researchers, medical educators, clinicians).</p

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Brain oscillations and connectivity in autism spectrum disorders (ASD):new approaches to methodology, measurement and modelling

    Get PDF
    Although atypical social behaviour remains a key characterisation of ASD, the presence ofsensory and perceptual abnormalities has been given a more central role in recentclassification changes. An understanding of the origins of such aberrations could thus prove afruitful focus for ASD research. Early neurocognitive models of ASD suggested that thestudy of high frequency activity in the brain as a measure of cortical connectivity mightprovide the key to understanding the neural correlates of sensory and perceptual deviations inASD. As our review shows, the findings from subsequent research have been inconsistent,with a lack of agreement about the nature of any high frequency disturbances in ASD brains.Based on the application of new techniques using more sophisticated measures of brainsynchronisation, direction of information flow, and invoking the coupling between high andlow frequency bands, we propose a framework which could reconcile apparently conflictingfindings in this area and would be consistent both with emerging neurocognitive models ofautism and with the heterogeneity of the condition

    Mortality and pulmonary complications in patients undergoing surgery with perioperative SARS-CoV-2 infection: an international cohort study

    Get PDF
    Background: The impact of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on postoperative recovery needs to be understood to inform clinical decision making during and after the COVID-19 pandemic. This study reports 30-day mortality and pulmonary complication rates in patients with perioperative SARS-CoV-2 infection. Methods: This international, multicentre, cohort study at 235 hospitals in 24 countries included all patients undergoing surgery who had SARS-CoV-2 infection confirmed within 7 days before or 30 days after surgery. The primary outcome measure was 30-day postoperative mortality and was assessed in all enrolled patients. The main secondary outcome measure was pulmonary complications, defined as pneumonia, acute respiratory distress syndrome, or unexpected postoperative ventilation. Findings: This analysis includes 1128 patients who had surgery between Jan 1 and March 31, 2020, of whom 835 (74·0%) had emergency surgery and 280 (24·8%) had elective surgery. SARS-CoV-2 infection was confirmed preoperatively in 294 (26·1%) patients. 30-day mortality was 23·8% (268 of 1128). Pulmonary complications occurred in 577 (51·2%) of 1128 patients; 30-day mortality in these patients was 38·0% (219 of 577), accounting for 81·7% (219 of 268) of all deaths. In adjusted analyses, 30-day mortality was associated with male sex (odds ratio 1·75 [95% CI 1·28–2·40], p\textless0·0001), age 70 years or older versus younger than 70 years (2·30 [1·65–3·22], p\textless0·0001), American Society of Anesthesiologists grades 3–5 versus grades 1–2 (2·35 [1·57–3·53], p\textless0·0001), malignant versus benign or obstetric diagnosis (1·55 [1·01–2·39], p=0·046), emergency versus elective surgery (1·67 [1·06–2·63], p=0·026), and major versus minor surgery (1·52 [1·01–2·31], p=0·047). Interpretation: Postoperative pulmonary complications occur in half of patients with perioperative SARS-CoV-2 infection and are associated with high mortality. Thresholds for surgery during the COVID-19 pandemic should be higher than during normal practice, particularly in men aged 70 years and older. Consideration should be given for postponing non-urgent procedures and promoting non-operative treatment to delay or avoid the need for surgery. Funding: National Institute for Health Research (NIHR), Association of Coloproctology of Great Britain and Ireland, Bowel and Cancer Research, Bowel Disease Research Foundation, Association of Upper Gastrointestinal Surgeons, British Association of Surgical Oncology, British Gynaecological Cancer Society, European Society of Coloproctology, NIHR Academy, Sarcoma UK, Vascular Society for Great Britain and Ireland, and Yorkshire Cancer Research

    DarkSide-50, a background free experiment for dark matter searches

    No full text
    The existence of dark matter is inferred from gravitational effects, but its nature remains a deep mystery. One possibility, motivated by considerations in elementary particle physics, is that dark matter consists of elementary particles, such as the hypothesized Weakly Interacting Massive Particles (WIMPs), with mass ~ 100 GeV and cross-section ~ 10−47 cm2, that can be gravitationally trapped inside our galaxy and revealed by their scattering on nuclei. It should be possible to detect WIMPs directly, as the orbital motion of the WIMPs composing the dark matter halo pervading the galaxy should result in WIMP-nucleus collisions of sufficient energy to be observable in the laboratory. The DarkSide-50 experiment is a direct WIMP search using a Liquid Argon Time Projection Chamber (LAr-TPC) with an active mass of 50 kg with a high sensitivity and an ultra-low background detector

    The Electronics and Data Acquisition System of the DarkSide Dark Matter Search

    No full text
    It is generally inferred from astronomical measurements th at Dark Matter (DM) comprises approximately 27% of the energy-dens ity of the universe. If DM is a subatomic particle, a possible candidate is a Weakl y Interacting Mas- sive Particle (WIMP), and the DarkSide-50 (DS) experiment i s a direct search for evidence of WIMP-nuclear collisions. DS is located undergr ound at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of thr ee active, embedded components; an outer water veto (CTF), a liquid scintillato r veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This pap er describes the data acquisition and electronic systems of the DS detectors , designed to detect the residual ionization from

    First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso

    No full text
    We report the first results of DarkSide-50, a direct search for dark matter operating in the un- derground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a ( 46.4 0.7 ) kg active mass, operated inside a 30 t or- ganic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a ( 1422 67 ) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1 1
    corecore