7 research outputs found

    Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades

    Get PDF
    Objective: With the increasing life expectancy for patients with cystic fibrosis (CF), and a known predisposition to certain cancers, cumulative radiation exposure from radiologic imaging is of increasing significance. This study explores the estimated cumulative effective radiation dose over a 17-year period from radiologic procedures and changing trends of imaging modalities over this period. Methods: Estimated cumulative effective dose (CED) from all thoracic and extrathoracic imaging modalities and interventional radiology procedures for both adult and pediatric patients with CF, exclusively attending a nationally designated CF center between 1992-2009 for > 1 year, was determined. The study period was divided into three equal tertiles, and estimated CED attributable to all radiologic procedures was estimated for each tertile. Results: Two hundred thirty patients met inclusion criteria (2,240 person-years of follow-up; 5,596 radiologic procedures). CED was > 75 mSv for one patient (0.43%), 36 patients (15.6%) had a CED between 20 and 75 mSv, 56 patients (24.3%) had a CED between 5 and 20 mSv, and in 138 patients (60%) the CED was estimated to be between 0 and 5 mSv over the study period. The mean annual CED per patient increased consecutively from 0.39 mSv/y to 0.47 mSv/y to 1.67 mSv/y over the tertiles one to three of the study period, respectively (P < .001). Thoracic imaging accounted for 46.9% of the total CED and abdominopelvic imaging accounted for 42.9% of the CED, respectively. There was an associated 5.9-fold increase in the use of all CT scanning per patient (P < .001). Conclusions: This study highlights the increasing exposure to ionizing radiation to patients with CF as a result of diagnostic imaging, primarily attributable to CT scanning. Increased awareness of CED and strategies to reduce this exposure are needed

    A Metal Oxide Semiconductor ionizing radiation detector architecture with increased voltage sensitivity

    Get PDF
    A Metal Oxide Semiconductor (MOS) ionizing radiation detector architecture which senses trapped charge in the dielectric due to incident ionizing radiation is presented. The detector architecture increases output voltage signal as a function of trapped charge in the sensing dielectric in comparison with state of the art MOSFET (RADFET) technology. Numerical simulations were employed to help develop the device concept. It is shown that an improved voltage sensitivity is possible due to a reduction in the sensing capacitance which, unlike RADFET technology, is decoupled from the dielectric capacitance. An initial prototype of the detector has been fabricated in the silicon fabrication facility of Tyndall National Institute and irradiation experiments have been performed which confirm the improved voltage sensitivity versus commercial RADFET detectors. It is envisaged that further sensitivity increases may be possible by integrating dielectrics other than silicon dioxide.X JUBILEE International Conference on Radiation in Various Fields of Research : RAD 2022 (Spring Edition) : book of abstracts; June 13-17, 2022; Herceg Novi, Montenegr

    Pure iterative reconstruction improves image quality in computed tomography of the abdomen and pelvis acquired at substantially reduced radiation doses in patients with active Crohn disease

    Get PDF
    Objective: We assessed diagnostic accuracy and image quality of modified protocol (MP) computed tomography (CT) of the abdomen and pelvis reconstructed using pure iterative reconstruction (IR) in patients with Crohn disease (CD). Methods: Thirty-four consecutive patients with CD were referred with suspected extramural complications. Two contemporaneous CT datasets were acquired in all patients: standard protocol (SP) and MP. The MP and SP protocols were designed to impart radiation exposures of 10% to 20% and 80% to 90% of routine abdominopelvic CT, respectively. The MP images were reconstructed with model-based IR (MBIR) and adaptive statistical IR (ASIR). Results: The MP-CT and SP-CT dose length product were 88 (58) mGy.cm (1.27 [0.87] mSv) and 303 [204] mGy.cm (4.8 [2.99] mSv), respectively (P < 0.001). Median diagnostic acceptability, spatial resolution, and contrast resolution were significantly higher and subjective noise scores were significantly lower on SP-ASIR 40 compared with all MP datasets. There was perfect clinical agreement between MP-MBIR and SP-ASIR 40 images for detection of extramural complications. Conclusions: Modified protocol CT using pure IR is feasible for assessment of active CD

    Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients.

    Get PDF
    Purpose: To develop low-dose thin-section computed tomographic (CT) protocols for assessment of cystic fibrosis (CF) in pediatric patients and determine the clinical usefulness thereof compared with chest radiography. Materials and Methods: After institutional review board approval and informed consent from patients or guardians were obtained, 14 patients with CF and 11 patients without CF (16 male, nine female; mean age, 12.6 years ± 5.4 [standard deviation]; range, 3.5–25 years) who underwent imaging for clinical reasons underwent low-dose thin-section CT. Sections 1 mm thick (protocol A) were used in 10 patients, and sections 0.5 mm thick (protocol B) were used in 15 patients at six levels at 120 kVp and 30–50 mA. Image quality and diagnostic acceptability were scored qualitatively and quantitatively by two radiologists who also quantified disease severity at thin-section CT and chest radiography. Effective doses were calculated by using a CT dosimetry calculator. Results: Low-dose thin-section CT was performed with mean effective doses of 0.19 mSv ± 0.03 for protocol A and 0.14 mSv ± 0.04 for protocol B (P < .005). Diagnostic acceptability and depiction of bronchovascular structures at lung window settings were graded as almost excellent for both protocols, but protocol B was inferior to protocol A for mediastinal assessment (P < .02). Patients with CF had moderate lung disease with a mean Bhalla score of 9.2 ± 5.3 (range, 0–19), compared with that of patients without CF (1.1 ± 1.4; P < .001). There was excellent correlation between thin-section CT and chest radiography (r = 0.88–0.92; P < .001). Conclusion: Low-dose thin-section CT can be performed at lower effective doses than can standard CT, approaching those of chest radiography. Low-dose thin-section CT could be appropriate for evaluating bronchiectasis in pediatric patients, yielding appropriate information about lung parenchyma and bronchovascular structures

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    No full text

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    No full text
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical science. © The Author(s) 2019. Published by Oxford University Press
    corecore