26 research outputs found

    Teaching argumentative synthesis writing through deliberative dialogues: instructional practices in secondary education

    Get PDF
    Dialogical argumentation practice contributes positively to argumentative writing skills. Specifically, deliberative dialogues are effective in promoting argument and counterargument integration in students' essays. However, the potential of dialogic activities may be increased if they are combined with instructional practices. The primary objective of this research is to compare the impact of four intervention programs, aimed at improving argumentative synthesis writing from conflicting sources. The four programs resulted from the combination of two instructional components (Explicit Instruction through video modelling—EI, or a Procedural Guideline—G), while Deliberative Dialogues—DD—were a constant element. We conducted a pre-post quasi-experimental study in which 186 Spanish third grade secondary school students (aged 14–15) participated. We evaluated the quality of the syntheses by examining the level of argumentative coverage (the total number of arguments included in the synthesis) and the level of integration (the type and frequency of the argumentative strategies used in the syntheses). The results showed that the effectiveness of the instructional methods varies according to the synthesis quality indicator. Explicit instruction, in combination with deliberative dialogues, was especially helpful in improving the level of integration of syntheses. The procedural guideline, in combination with deliberative dialogues, contributed significantly to the coverage of arguments. The combination of these two elements did not favor the writing of synthesis as expected, probably due to the conditions in which the intervention was carried out. The findings of this study revealed that the coverage of arguments and integration processes are of different nature, follow different learning paths and require different instructional processes.pre-print875 K

    Search for the standard model Higgs boson at LEP

    Get PDF

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la GuĂ­a española para el manejo del asma (GEMA 2009 y 2015) y su repercusiĂłn en el control de la enfermedad. Material y mĂ©todos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 mĂ©dicos de atenciĂłn primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 mĂ©dicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 mĂ©dicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguĂ­an las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asociĂł de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guĂ­as clĂ­nicas para el manejo del asma constituye un problema comĂșn entre los mĂ©dicos de atenciĂłn primaria. Un seguimiento de estas guĂ­as se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los mĂ©dicos de atenciĂłn primaria de las guĂ­as para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (GuĂ­a Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Electroweak measurements in electron–positron collisions at w-boson-pair energies at lep

    Get PDF
    Contains fulltext : 121524.pdf (preprint version ) (Open Access

    Effects of previous episodes of influenza and vaccination in preventing laboratory-confirmed influenza in Navarre, Spain, 2013/14 season

    No full text
    Publisher Copyright: © 2016, European Centre for Disease Prevention and Control (ECDC), All rights reserved.We estimated whether previous episodes of influenza and trivalent influenza vaccination prevented laboratory- confirmed influenza in Navarre, Spain, in season 2013/14. Patients with medically-attended influenzalike illness (MA-ILI) in hospitals (n = 645) and primary healthcare (n = 525) were included. We compared 589 influenza cases and 581 negative controls. MA-ILI related to a specific virus subtype in the previous five seasons was defined as a laboratory-confirmed influenza infection with the same virus subtype or MA-ILI during weeks when more than 25% of swabs were positive for this subtype. Persons with previous MA-ILI had 30% (95% confidence interval (CI): −7 to 54) lower risk of MA-ILI, and those with previous MA-ILI related to A(H1N1)pdm09 or A(H3N2) virus, had a, respectively, 63% (95% CI: 16–84) and 65% (95% CI: 13–86) lower risk of new laboratory-confirmed influenza by the same subtype. Overall adjusted vaccine effectiveness in preventing laboratory-confirmed influenza was 31% (95% CI: 5–50): 45% (95% CI: 12–65) for A(H1N1) pdm09 and 20% (95% CI: −16 to 44) for A(H3N2). While a previous influenza episode induced high protection only against the same virus subtype, influenza vaccination provided low to moderate protection against all circulating subtypes. Influenza vaccine remains the main preventive option for high-risk populations.Peer reviewe
    corecore