429 research outputs found

    Time frequency analysis in terahertz pulsed imaging

    Get PDF
    Recent advances in laser and electro-optical technologies have made the previously under-utilized terahertz frequency band of the electromagnetic spectrum accessible for practical imaging. Applications are emerging, notably in the biomedical domain. In this chapter the technique of terahertz pulsed imaging is introduced in some detail. The need for special computer vision methods, which arises from the use of pulses of radiation and the acquisition of a time series at each pixel, is described. The nature of the data is a challenge since we are interested not only in the frequency composition of the pulses, but also how these differ for different parts of the pulse. Conventional and short-time Fourier transforms and wavelets were used in preliminary experiments on the analysis of terahertz pulsed imaging data. Measurements of refractive index and absorption coefficient were compared, wavelet compression assessed and image classification by multidimensional clustering techniques demonstrated. It is shown that the timefrequency methods perform as well as conventional analysis for determining material properties. Wavelet compression gave results that were robust through compressions that used only 20% of the wavelet coefficients. It is concluded that the time-frequency methods hold great promise for optimizing the extraction of the spectroscopic information contained in each terahertz pulse, for the analysis of more complex signals comprising multiple pulses or from recently introduced acquisition techniques

    Home telemonitoring or structured telephone support programmes after recent discharge in patients with heart failure: systematic review and economic evaluation

    Get PDF
    BACKGROUND: Remote monitoring (RM) strategies have the potential to deliver specialised care and management to patients with heart failure (HF). OBJECTIVE: To determine the clinical effectiveness and cost-effectiveness of home telemonitoring (TM) or structured telephone support (STS) strategies compared with usual care for adult patients who have been recently discharged (within 28 days) from acute care after a recent exacerbation of HF. DATA SOURCES: Fourteen electronic databases (including MEDLINE, EMBASE, PsycINFO and The Cochrane Library) and research registers were searched to January 2012, supplemented by hand-searching relevant articles and contact with experts. The review included randomised controlled trials (RCTs) or observational cohort studies with a contemporaneous control group that included the following RM interventions: (1) TM (including cardiovascular implanted monitoring devices) with medical support provided during office hours or 24/7; (2) STS programmes delivered by human-to-human contact (HH) or human-to-machine interface (HM). REVIEW METHODS: A systematic review and network meta-analysis (where appropriate) of the clinical evidence was carried out using standard methods. A Markov model was developed to evaluate the cost-effectiveness of different RM packages compared with usual care for recently discharged HF patients. TM 24/7 or using cardiovascular monitoring devices was not considered in the economic model because of the lack of data and/or unsuitability for the UK setting. Given the heterogeneity in the components of usual care and RM interventions, the cost-effectiveness analysis was performed using a set of costing scenarios designed to reflect the different configurations of usual care and RM in the UK. RESULTS: The literature searches identified 3060 citations. Six RCTs met the inclusion criteria and were added to the 15 trials identified from the previous systematic reviews giving a total of 21 RCTs included in the systematic review. No trials of cardiovascular implanted monitoring devices or observational studies met the inclusion criteria. The methodological quality of the studies varied widely and reporting was generally poor. Compared with usual care, RM was beneficial in reducing all-cause mortality for STS HH [hazard ratio (HR) 0.77, 95% credible interval (CrI) 0.55 to 1.08], TM during office hours (HR 0.76, 95% CrI 0.49 to 1.18) and TM 24/7 (HR 0.49, 95% CrI 0.20 to 1.18); however, these results were statistically inconclusive. The results for TM 24/7 should be treated with caution because of the poor methodological quality of the only included study in this network. No favourable effect on mortality was observed with STS HM. Similar reductions were observed in all-cause hospitalisations for TM interventions, whereas STS interventions had no major effect. A sensitivity analysis, in which a study was excluded because it provided better-than-usual support to the control group, showed larger beneficial effects for most outcomes, particularly for TM during office hours. In the cost-effectiveness analyses, TM during office hours was the most cost-effective strategy with an estimated incremental cost-effectiveness ratio (ICER) of ÂŁ11,873 per quality-adjusted life-year (QALY) compared with usual care, whereas STS HH had an ICER of ÂŁ228,035 per QALY compared with TM during office hours. STS HM was dominated by usual care. Similar results were observed in scenario analyses performed using higher costs of usual care, higher costs of STS HH and lower costs of TM during office hours. LIMITATIONS: The RM interventions included in the review were heterogeneous in terms of monitored parameters and HF selection criteria and lacked detail in the components of the RM care packages and usual care (e.g. communication protocols, routine staff visits and resources used). As a result, the economic model developed scenarios for different RM classifications and their costs were estimated using bottom-up costing methods. Although the users can decide which of these scenarios is most representative of their setting, uncertainties still remain about the assumptions made in the estimation of these costs. In addition, the model assumed that the effectiveness of the interventions was constant over time, irrespective of the duration of deployment, and that the intervention was equally effective in different age/severity groups. CONCLUSION: Despite wide variation in usual care and RM strategies, cost-effectiveness analyses suggest that TM during office hours was an optimal strategy (in most costing scenarios). However, clarity was lacking among descriptions of the components of RM packages and usual care and there was a lack of robust estimation of costs. Further research is needed in these areas. STUDY REGISTRATION: PROSPERO registration no. CRD42011001368. FUNDING: The National Institute for Health Research Health Technology Assessment programme

    Combinatorial detection of autoreactive CD8+ T cells with HLA-A2 multimers: a multi-centre study by the Immunology of Diabetes Society T Cell Workshop

    Get PDF
    Aims/hypothesis: Validated biomarkers are needed to monitor the effects of immune intervention in individuals with type 1 diabetes. Despite their importance, few options exist for monitoring antigen-specific T cells. Previous reports described a combinatorial approach that enables the simultaneous detection and quantification of multiple islet-specific CD8+ T cell populations. Here, we set out to evaluate the performance of a combinatorial HLA-A2 multimer assay in a multi-centre setting. Methods: The combinatorial HLA-A2 multimer assay was applied in five participating centres using centralised reagents and blinded replicate samples. In preliminary experiments, samples from healthy donors were analysed using recall antigen multimers. In subsequent experiments, samples from healthy donors and individuals with type 1 diabetes were analysed using beta cell antigen and recall antigen multimers. Results: The combinatorial assay was successfully implemented in each participating centre, with CVs between replicate samples that indicated good reproducibility for viral epitopes (mean %CV = 33.8). For beta cell epitopes, the assay was very effective in a single-centre setting (mean %CV = 18.4), but showed sixfold greater variability across multi-centre replicates (mean %CV = 119). In general, beta cell antigen-specific CD8+ T cells were detected more commonly in individuals with type 1 diabetes than in healthy donors. Furthermore, CD8+ T cells recognising HLA-A2-restricted insulin and glutamate decarboxylase epitopes were found to occur at higher frequencies in individuals with type 1 diabetes than in healthy donors. Conclusions/interpretation Our results suggest that, although combinatorial multimer assays are challenging, they can be implemented in multiple laboratories, providing relevant T cell frequency measurements. Assay reproducibility was notably higher in the single-centre setting, suggesting that biomarker analysis of clinical trial samples would be most successful when assays are performed in a single laboratory. Technical improvements, including further standardisation of cytometry platforms, will likely be necessary to reduce assay variability in the multi-centre setting

    Effects of Cooling During Exercise on Thermoregulatory Responses of Men With Paraplegia.

    Get PDF
    BACKGROUND: People with spinal cord injury (SCI) have an altered afferent input to the thermoregulatory center, resulting in a reduced efferent response (vasomotor control and sweating capacity) below the level of the lesion. Consequently, core body temperature rises more rapidly during exercise in individuals with SCI compared with people who are able-bodied. Cooling strategies may reduce the thermophysiological strain in SCI. OBJECTIVE: The aim of this study was to examine the effects of a cooling vest on the core body temperature response of people with a thoracic SCI during submaximal exercise. METHODS: Ten men (mean age=44 years, SD=11) with a thoracic lesion (T4-T5 or below) participated in this randomized crossover study. Participants performed two 45-minute exercise bouts at 50% maximal workload (ambient temperature 25°C), with participants randomized to a group wearing a cooling vest or a group wearing no vest (separate days). Core body temperature and skin temperature were continuously measured, and thermal sensation was assessed every 3 minutes. RESULTS: Exercise resulted in an increased core body temperature, skin temperature, and thermal sensation, whereas cooling did not affect core body temperature. The cooling vest effectively decreased skin temperature, increased the core-to-trunk skin temperature gradient, and tended to lower thermal sensation compared with the control condition. LIMITATIONS: The lack of differences in core body temperature among conditions may be a result of the relative moderate ambient temperature in which the exercise was performed. CONCLUSIONS: Despite effectively lowering skin temperature and increasing the core-to-trunk skin temperature gradient, there was no impact of the cooling vest on the exercise-induced increase in core body temperature in men with low thoracic SCI

    Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study

    Get PDF
    A41 Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study In: Addiction Science & Clinical Practice 2017, 12(Suppl 1): A4

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Measurement of the branching ratio Γ(Λb⁰ → ψ(2S)Λ0)/Γ(Λb⁰ → J/ψΛ0) with the ATLAS detector

    Get PDF
    An observation of the Λb0→ψ(2S)Λ0\Lambda_b^0 \rightarrow \psi(2S) \Lambda^0 decay and a comparison of its branching fraction with that of the Λb0→J/ψΛ0\Lambda_b^0 \rightarrow J/\psi \Lambda^0 decay has been made with the ATLAS detector in proton--proton collisions at s=8 \sqrt{s}=8\,TeV at the LHC using an integrated luminosity of 20.6 20.6\,fb−1^{-1}. The J/ψJ/\psi and ψ(2S)\psi(2S) mesons are reconstructed in their decays to a muon pair, while the Λ0→pπ−\Lambda^0\rightarrow p\pi^- decay is exploited for the Λ0\Lambda^0 baryon reconstruction. The Λb0\Lambda_b^0 baryons are reconstructed with transverse momentum pT>10 p_{\rm T}>10\,GeV and pseudorapidity ∣η∣<2.1|\eta|<2.1. The measured branching ratio of the Λb0→ψ(2S)Λ0\Lambda_b^0 \rightarrow \psi(2S) \Lambda^0 and Λb0→J/ψΛ0\Lambda_b^0 \rightarrow J/\psi \Lambda^0 decays is Γ(Λb0→ψ(2S)Λ0)/Γ(Λb0→J/ψΛ0)=0.501±0.033(stat)±0.019(syst)\Gamma(\Lambda_b^0 \rightarrow \psi(2S)\Lambda^0)/\Gamma(\Lambda_b^0 \rightarrow J/\psi\Lambda^0) = 0.501\pm 0.033 ({\rm stat})\pm 0.019({\rm syst}), lower than the expectation from the covariant quark model.Comment: 12 pages plus author list (28 pages total), 5 figures, 1 table, published on Physics Letters B 751 (2015) 63-80. All figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/BPHY-2013-08
    • 

    corecore