1,901 research outputs found
The impact of point mutations in the human androgen receptor : classification of mutations on the basis of transcriptional activity
Peer reviewedPublisher PD
The Subluminous Supernova 2007qd: A Missing Link in a Family of Low-Luminosity Type Ia Supernovae
We present multi-band photometry and multi-epoch spectroscopy of the peculiar
Type Ia supernova (SN Ia) 2007qd, discovered by the SDSS-II Supernova Survey.
It possesses physical properties intermediate to those of the peculiar SN
2002cx and the extremely low-luminosity SN 2008ha. Optical photometry indicates
that it had an extraordinarily fast rise time of <= 10 days and a peak absolute
B magnitude of -15.4 +/- 0.2 at most, making it one of the most subluminous SN
Ia ever observed. Follow-up spectroscopy of SN 2007qd near maximum brightness
unambiguously shows the presence of intermediate-mass elements which are likely
caused by carbon/oxygen nuclear burning. Near maximum brightness, SN 2007qd had
a photospheric velocity of only 2800 km/s, similar to that of SN 2008ha but
about 4000 and 7000 km/s less than that of SN 2002cx and normal SN Ia,
respectively. We show that the peak luminosities of SN 2002cx-like objects are
highly correlated with both their light-curve stretch and photospheric
velocities. Its strong apparent connection to other SN 2002cx-like events
suggests that SN 2007qd is also a pure deflagration of a white dwarf, although
other mechanisms cannot be ruled out. It may be a critical link between SN
2008ha and the other members of the SN 2002cx-like class of objects.Comment: To be published in the Astrophysical Journal; 37 pages, 13 figures, 4
table
The anti-bacterial iron-restriction defence mechanisms of egg white; the potential role of three lipocalin-like proteins in resistance against Salmonella
Salmonella enterica serovar Enteritidis (SE) is the most frequently-detected Salmonella in foodborne outbreaks in the European Union. Among such outbreaks, egg and egg products were identified as the most common vehicles of infection. Possibly, the major antibacterial property of egg white is iron restriction, which results from the presence of the iron-binding protein, ovotransferrin. To circumvent iron restriction, SE synthesise catecholate siderophores (i.e. enterobactin and salmochelin) that can chelate iron from host iron-binding proteins. Here, we highlight the role of lipocalin-like proteins found in egg white that could enhance egg-white iron restriction through sequestration of certain siderophores, including enterobactin. Indeed, it is now apparent that the egg-white lipocalin, Ex-FABP, can inhibit bacterial growth via its siderophore-binding capacity in vitro. However, it remains unclear whether ex-FABP performs such a function in egg white or during bird infection. Regarding the two other lipocalins of egg white (Cal-γ and α-1-glycoprotein), there is currently no evidence to indicate that they sequester siderophores
The Metagenomics and Metadesign of the Subways and Urban Biomes (MetaSUB) International Consortium inaugural meeting report
The Metagenomics and Metadesign of the Subways and Urban Biomes (MetaSUB) International Consortium is a novel, interdisciplinary initiative comprised of experts across many fields, including genomics, data analysis, engineering, public health, and architecture. The ultimate goal of the MetaSUB Consortium is to improve city utilization and planning through the detection, measurement, and design of metagenomics within urban environments. Although continual measures occur for temperature, air pressure, weather, and human activity, including longitudinal, cross-kingdom ecosystem dynamics can alter and improve the design of cities. The MetaSUB Consortium is aiding these efforts by developing and testing metagenomic methods and standards, including optimized methods for sample collection, DNA/RNA isolation, taxa characterization, and data visualization. The data produced by the consortium can aid city planners, public health officials, and architectural designers. In addition, the study will continue to lead to the discovery of new species, global maps of antimicrobial resistance (AMR) markers, and novel biosynthetic gene clusters (BGCs). Finally, we note that engineered metagenomic ecosystems can help enable more responsive, safer, and quantified cities
Measurements of the pp → ZZ production cross section and the Z → 4ℓ branching fraction, and constraints on anomalous triple gauge couplings at √s = 13 TeV
Four-lepton production in proton-proton collisions, pp -> (Z/gamma*)(Z/gamma*) -> 4l, where l = e or mu, is studied at a center-of-mass energy of 13 TeV with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb(-1). The ZZ production cross section, sigma(pp -> ZZ) = 17.2 +/- 0.5 (stat) +/- 0.7 (syst) +/- 0.4 (theo) +/- 0.4 (lumi) pb, measured using events with two opposite-sign, same-flavor lepton pairs produced in the mass region 60 4l) = 4.83(-0.22)(+0.23) (stat)(-0.29)(+0.32) (syst) +/- 0.08 (theo) +/- 0.12(lumi) x 10(-6) for events with a four-lepton invariant mass in the range 80 4GeV for all opposite-sign, same-flavor lepton pairs. The results agree with standard model predictions. The invariant mass distribution of the four-lepton system is used to set limits on anomalous ZZZ and ZZ. couplings at 95% confidence level: -0.0012 < f(4)(Z) < 0.0010, -0.0010 < f(5)(Z) < 0.0013, -0.0012 < f(4)(gamma) < 0.0013, -0.0012 < f(5)(gamma) < 0.0013
Search for heavy resonances decaying to two Higgs bosons in final states containing four b quarks
A search is presented for narrow heavy resonances X decaying into pairs of Higgs bosons (H) in proton-proton collisions collected by the CMS experiment at the LHC at root s = 8 TeV. The data correspond to an integrated luminosity of 19.7 fb(-1). The search considers HH resonances with masses between 1 and 3 TeV, having final states of two b quark pairs. Each Higgs boson is produced with large momentum, and the hadronization products of the pair of b quarks can usually be reconstructed as single large jets. The background from multijet and t (t) over bar events is significantly reduced by applying requirements related to the flavor of the jet, its mass, and its substructure. The signal would be identified as a peak on top of the dijet invariant mass spectrum of the remaining background events. No evidence is observed for such a signal. Upper limits obtained at 95 confidence level for the product of the production cross section and branching fraction sigma(gg -> X) B(X -> HH -> b (b) over barb (b) over bar) range from 10 to 1.5 fb for the mass of X from 1.15 to 2.0 TeV, significantly extending previous searches. For a warped extra dimension theory with amass scale Lambda(R) = 1 TeV, the data exclude radion scalar masses between 1.15 and 1.55 TeV
Minimally invasive and endoscopic versus open necrosectomy for necrotising pancreatitis: a pooled analysis of individual data for 1980 patients
Minimally invasive surgical necrosectomy and endoscopic necrosectomy, compared with open necrosectomy, might improve outcomes in necrotising pancreatitis, especially in critically ill patients. Evidence from large comparative studies is lacking. We combined original and newly collected data from 15 published and unpublished patient cohorts (51 hospitals; 8 countries) on pancreatic necrosectomy for necrotising pancreatitis. Death rates were compared in patients undergoing open necrosectomy versus minimally invasive surgical or endoscopic necrosectomy. To adjust for confounding and to study effect modification by clinical severity, we performed two types of analyses: logistic multivariable regression and propensity score matching with stratification according to predicted risk of death at baseline (low: <5%; intermediate: ≥5% to <15%; high: ≥15% to <35%; and very high: ≥35%). Among 1980 patients with necrotising pancreatitis, 1167 underwent open necrosectomy and 813 underwent minimally invasive surgical (n=467) or endoscopic (n=346) necrosectomy. There was a lower risk of death for minimally invasive surgical necrosectomy (OR, 0.53; 95% CI 0.34 to 0.84; p=0.006) and endoscopic necrosectomy (OR, 0.20; 95% CI 0.06 to 0.63; p=0.006). After propensity score matching with risk stratification, minimally invasive surgical necrosectomy remained associated with a lower risk of death than open necrosectomy in the very high-risk group (42/111 vs 59/111; risk ratio, 0.70; 95% CI 0.52 to 0.95; p=0.02). Endoscopic necrosectomy was associated with a lower risk of death than open necrosectomy in the high-risk group (3/40 vs 12/40; risk ratio, 0.27; 95% CI 0.08 to 0.88; p=0.03) and in the very high-risk group (12/57 vs 28/57; risk ratio, 0.43; 95% CI 0.24 to 0.77; p=0.005). In high-risk patients with necrotising pancreatitis, minimally invasive surgical and endoscopic necrosectomy are associated with reduced death rates compared with open necrosectom
The Boston criteria version 2.0 for cerebral amyloid angiopathy:a multicentre, retrospective, MRI–neuropathology diagnostic accuracy study
BACKGROUND: Cerebral amyloid angiopathy (CAA) is an age-related small vessel disease, characterised pathologically by progressive deposition of amyloid β in the cerebrovascular wall. The Boston criteria are used worldwide for the in-vivo diagnosis of CAA but have not been updated since 2010, before the emergence of additional MRI markers. We report an international collaborative study aiming to update and externally validate the Boston diagnostic criteria across the full spectrum of clinical CAA presentations. METHODS: In this multicentre, hospital-based, retrospective, MRI and neuropathology diagnostic accuracy study, we did a retrospective analysis of clinical, radiological, and histopathological data available to sites participating in the International CAA Association to formulate updated Boston criteria and establish their diagnostic accuracy across different populations and clinical presentations. Ten North American and European academic medical centres identified patients aged 50 years and older with potential CAA-related clinical presentations (ie, spontaneous intracerebral haemorrhage, cognitive impairment, or transient focal neurological episodes), available brain MRI, and histopathological assessment for CAA diagnosis. MRI scans were centrally rated at Massachusetts General Hospital (Boston, MA, USA) for haemorrhagic and non-haemorrhagic CAA markers, and brain tissue samples were rated by neuropathologists at the contributing sites. We derived the Boston criteria version 2.0 (v2.0) by selecting MRI features to optimise diagnostic specificity and sensitivity in a prespecified derivation cohort (Boston cases 1994-2012, n=159), then externally validated the criteria in a prespecified temporal validation cohort (Boston cases 2012-18, n=59) and a geographical validation cohort (non-Boston cases 2004-18; n=123), comparing accuracy of the new criteria to the currently used modified Boston criteria with histopathological assessment of CAA as the diagnostic standard. We also assessed performance of the v2.0 criteria in patients across all cohorts who had the diagnostic gold standard of brain autopsy. FINDINGS: The study protocol was finalised on Jan 15, 2017, patient identification was completed on Dec 31, 2018, and imaging analyses were completed on Sept 30, 2019. Of 401 potentially eligible patients presenting to Massachusetts General Hospital, 218 were eligible to be included in the analysis; of 160 patient datasets from other centres, 123 were included. Using the derivation cohort, we derived provisional criteria for probable CAA requiring the presence of at least two strictly lobar haemorrhagic lesions (ie, intracerebral haemorrhages, cerebral microbleeds, or foci of cortical superficial siderosis) or at least one strictly lobar haemorrhagic lesion and at least one white matter characteristic (ie, severe visible perivascular spaces in centrum semiovale or white matter hyperintensities in a multispot pattern). The sensitivity and specificity of these criteria were 74·8% (95% CI 65·4-82·7) and 84·6% (71·9-93·1) in the derivation cohort, 92·5% (79·6-98·4) and 89·5% (66·9-98·7) in the temporal validation cohort, 80·2% (70·8-87·6) and 81·5% (61·9-93·7) in the geographical validation cohort, and 74·5% (65·4-82·4) and 95·0% (83·1-99·4) in all patients who had autopsy as the diagnostic standard. The area under the receiver operating characteristic curve (AUC) was 0·797 (0·732-0·861) in the derivation cohort, 0·910 (0·828-0·992) in the temporal validation cohort, 0·808 (0·724-0·893) in the geographical validation cohort, and 0·848 (0·794-0·901) in patients who had autopsy as the diagnostic standard. The v2.0 Boston criteria for probable CAA had superior accuracy to the current Boston criteria (sensitivity 64·5% [54·9-73·4]; specificity 95·0% [83·1-99·4]; AUC 0·798 [0·741-0854]; p=0·0005 for comparison of AUC) across all individuals who had autopsy as the diagnostic standard. INTERPRETATION: The Boston criteria v2.0 incorporate emerging MRI markers of CAA to enhance sensitivity without compromising their specificity in our cohorts of patients aged 50 years and older presenting with spontaneous intracerebral haemorrhage, cognitive impairment, or transient focal neurological episodes. Future studies will be needed to determine generalisability of the v.2.0 criteria across the full range of patients and clinical presentations. FUNDING: US National Institutes of Health (R01 AG26484)
Impact of electronic medical record on physician practice in office settings: a systematic review
<p>Abstract</p> <p>Background</p> <p>Increased investments are being made for electronic medical records (EMRs) in Canada. There is a need to learn from earlier EMR studies on their impact on physician practice in office settings. To address this need, we conducted a systematic review to examine the impact of EMRs in the physician office, factors that influenced their success, and the lessons learned.</p> <p>Results</p> <p>For this review we included publications cited in Medline and CINAHL between 2000 and 2009 on physician office EMRs. Studies were included if they evaluated the impact of EMR on physician practice in office settings. The Clinical Adoption Framework provided a conceptual scheme to make sense of the findings and allow for future comparison/alignment to other Canadian eHealth initiatives.</p> <p>In the final selection, we included 27 controlled and 16 descriptive studies. We examined six areas: prescribing support, disease management, clinical documentation, work practice, preventive care, and patient-physician interaction. Overall, 22/43 studies (51.2%) and 50/109 individual measures (45.9%) showed positive impacts, 18.6% studies and 18.3% measures had negative impacts, while the remaining had no effect. Forty-eight distinct factors were identified that influenced EMR success. Several lessons learned were repeated across studies: (a) having robust EMR features that support clinical use; (b) redesigning EMR-supported work practices for optimal fit; (c) demonstrating value for money; (d) having realistic expectations on implementation; and (e) engaging patients in the process.</p> <p>Conclusions</p> <p>Currently there is limited positive EMR impact in the physician office. To improve EMR success one needs to draw on the lessons from previous studies such as those in this review.</p
- …
