73 research outputs found

    Balancing Compression and Encryption of Satellite Imagery

    Get PDF
    With the rapid developments in the remote sensing technologies and services, there is a necessity for combined compression and encryption of satellite imagery. The onboard satellite compression is used to minimize storage and communication bandwidth requirements of high data rate satellite applications. While encryption is employed to secure these resources and prevent illegal use of image sensitive information. In this paper, we propose an approach to address these challenges which raised in the highly dynamic satellite based networked environment. This approach combined compression algorithms (Huffman and SPIHT) and encryptions algorithms (RC4, blowfish and AES) into three complementary modes: (1) secure lossless compression, (2) secure lossy compression and (3) secure hybrid compression. The extensive experiments on the 126 satellite images dataset showed that our approach outperforms traditional and state of art approaches by saving approximately (53%) of computational resources. In addition, the interesting feature of this approach is these three options that mimic reality by imposing every time a different approach to deal with the problem of limited computing and communication resources

    Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study.

    Get PDF
    Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty. Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and the use of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objective is to report the radiographic outcomes of patients with posterior glenoid wear and/or retroversion treated with either approach. Methods: Patients with posterior glenoid wear and a minimum of 15 degrees of retroversion, treated with AR and standard glenoid component or with a PAG component (3 mm, 5 mm, or 7 mm posterior augmentation), were consecutively identified through retrospective chart review. Pre-operative axillary views were evaluated for version, humeral head subluxation in relation to scapular axis and to mid-glenoid face. Post-operative axillary views were reviewed to measure corrected inversion and humeral head subluxation. Results: There were 48 patients in the AR group and 49 patients in the PAG group. Version improved 6.8 degrees in the AR group. In the PAG group, version improved 8.8 degrees with 3 mm augment, 13.4 degrees with 5 mm augment, and 12.8 with 7 mm augments. There were significantly more central peg perforations in the 5 mm PAG group compared to other groups. The humeral head was re-centered within 6.1% of normal in all groups except 7 mm augments. Conclusion: This study demonstrates that AR and PAGs have the ability to re-center the humeral head when utilized in patients with retroversion and posterior wear. Use of a PAG component may allow for greater correction of glenoid retroversion, however, there is an increased risk for central peg perforation with the specific implant utilized in this study. Long-term follow-up is ongoing and needed to understand the clinical implications of these findings

    Dynamic 3D shape of the plantar surface of the foot using coded structured light:a technical report

    Get PDF
    The foot provides a crucial contribution to the balance and stability of the musculoskeletal system, and accurate foot measurements are important in applications such as designing custom insoles/footwear. With better understanding of the dynamic behavior of the foot, dynamic foot reconstruction techniques are surfacing as useful ways to properly measure the shape of the foot. This paper presents a novel design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Methods Engineering and clinical tests were carried out to test the accuracy and repeatability of the system. Accuracy experiments involved imaging a planar surface from different orientations and elevations and measuring the fitting errors of the data to a plane. Repeatability experiments were done using reconstructions from 27 different subjects, where for each one both right and left feet were reconstructed in static and dynamic conditions over two different days. Results The static accuracy of the system was found to be 0.3 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.4 mm (static case) and 2.8 mm (dynamic case). Conclusion The results obtained in the experiments show positive accuracy and repeatability results when compared to current literature. The design also shows to be superior to the systems available in the literature in several factors. Further studies need to be done to quantify the reliability of the system in clinical environment

    Transcranial Doppler and Magnetic Resonance in Tanzanian Children With Sickle Cell Disease

    Get PDF
    Background and Purpose: We determined prevalences of neurological complications, vascular abnormality, and infarction in Tanzanian children with sickle cell disease. // Methods: Children with sickle cell disease were consecutively enrolled for transcranial Doppler; those with slightly elevated (>150 cm/s), low (150 cm/s was associated with frequent painful crises and low hemoglobin level. Absent/low CBFv was associated with low hemoglobin level and history of unilateral weakness. In 49 out of 67 children with low/absent/elevated transcranial Doppler undergoing magnetic resonance imaging, 43% had infarction, whereas 24 out of 48 (50%) magnetic resonance angiographies were abnormal. One had hemorrhagic infarction; none had microbleeds. Posterior circulation infarcts occurred in 14%. Of 11 children with previous seizure undergoing magnetic resonance imaging, 10 (91%) had infarction (5 silent) compared with 11 out of 38 (29%) of the remainder ( P=0.003). Of 7 children with clinical stroke, 2 had recurrent stroke and 3 died; 4 out of 5 had absent CBFv. Of 193 without stroke, 1 died and 1 had a stroke; both had absent CBFv. // Conclusions: In one-third of Tanzanian children with sickle cell disease, CBFv is outside the normal range, associated with frequent painful crises and low hemoglobin level, but not hemolysis. Half have abnormal magnetic resonance angiography. African children with sickle cell disease should be evaluated with transcranial Doppler; those with low/absent/elevated CBFv should undergo magnetic resonance imaging/magnetic resonance angiography

    A multi-targeted approach to suppress tumor-promoting inflammation

    Get PDF
    Cancers harbor significant genetic heterogeneity and patterns of relapse following many therapies are due to evolved resistance to treatment. While efforts have been made to combine targeted therapies, significant levels of toxicity have stymied efforts to effectively treat cancer with multi-drug combinations using currently approved therapeutics. We discuss the relationship between tumor-promoting inflammation and cancer as part of a larger effort to develop a broad-spectrum therapeutic approach aimed at a wide range of targets to address this heterogeneity. Specifically, macrophage migration inhibitory factor, cyclooxygenase-2, transcription factor nuclear factor-κB, tumor necrosis factor alpha, inducible nitric oxide synthase, protein kinase B, and CXC chemokines are reviewed as important antiinflammatory targets while curcumin, resveratrol, epigallocatechin gallate, genistein, lycopene, and anthocyanins are reviewed as low-cost, low toxicity means by which these targets might all be reached simultaneously. Future translational work will need to assess the resulting synergies of rationally designed antiinflammatory mixtures (employing low-toxicity constituents), and then combine this with similar approaches targeting the most important pathways across the range of cancer hallmark phenotypes

    Clinical research without consent in adults in the emergency setting: a review of patient and public views

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In emergency research, obtaining informed consent can be problematic. Research to develop and improve treatments for patients admitted to hospital with life-threatening and debilitating conditions is much needed yet the issue of research without consent (RWC) raises concerns about unethical practices and the loss of individual autonomy. Consistent with the policy and practice turn towards greater patient and public involvement in health care decisions, in the US, Canada and EU, guidelines and legislation implemented to protect patients and facilitate acute research with adults who are unable to give consent have been developed with little involvement of the lay public. This paper reviews research examining public opinion regarding RWC for research in emergency situations, and whether the rules and regulations permitting research of this kind are in accordance with the views of those who ultimately may be the most affected.</p> <p>Methods</p> <p>Seven electronic databases were searched: Medline, Embase, CINAHL, Cochrane Database of Systematic Reviews, Philosopher's Index, Age Info, PsychInfo, Sociological Abstracts and Web of Science. Only those articles pertaining to the views of the public in the US, Canada and EU member states were included. Opinion pieces and those not published in English were excluded.</p> <p>Results</p> <p>Considering the wealth of literature on the perspectives of professionals, there was relatively little information about public attitudes. Twelve studies employing a range of research methods were identified. In five of the six questionnaire surveys around half the sample did <it>not </it>agree generally with RWC, though paradoxically, a higher percentage would <it>personally </it>take part in such a study. Unfortunately most of the studies were not designed to investigate individuals' views in any depth. There also appears to be a level of mistrust of medical research and some patients were more likely to accept an experimental treatment 'outside' of a research protocol.</p> <p>Conclusion</p> <p>There are too few data to evaluate whether the rules and regulations permitting RWC protects – or is acceptable to – the public. However, any attempts to engage the public should take place in the context of findings from further basic research to attend to the apparently paradoxical findings of some of the current surveys.</p

    A phase II randomized trial comparing radiotherapy with concurrent weekly cisplatin or weekly paclitaxel in patients with advanced cervical cancer

    Get PDF
    <p>Abstract</p> <p>Purpose/Objective</p> <p>This is a prospective comparison of weekly cisplatin to weekly paclitaxel as concurrent chemotherapy with standard radiotherapy for locally advanced cervical carcinoma.</p> <p>Materials/Methods</p> <p>Between May 2000 and May 2004, 31 women with FIGO stage IB2-IVA cervical cancer or with postsurgical pelvic recurrence were enrolled into this phase II study and randomized to receive on a weekly basis either 40 mg/m<sup>2 </sup>Cisplatin (group I; 16 patients) or 50 mg/m<sup>2 </sup>paclitaxel (group II; 15 patients) concurrently with radiotherapy. Median total dose to point A was 74 Gy (range: 66-92 Gy) for group I and 66 Gy (range: 40-98 Gy) for group II. Median follow-up time was 46 months.</p> <p>Results</p> <p>Patient and tumor characteristics were similar in both groups. The mean number of chemotherapy cycles was also comparable with 87% and 80% of patients receiving at least 4 doses in groups I and II, respectively. Seven patients (44%) of group I and 8 patients (53%) of group II developed tumor recurrence. The Median Survival time was not reached for Group I and 53 months for group II. The proportion of patients surviving at 2 and 5 years was 78% and 54% for group I and 73% and 43% for group II respectively.</p> <p>Conclusions</p> <p>This small prospective study shows that weekly paclitaxel does not provide any clinical advantage over weekly cisplatin for concurrent chemoradiation for advanced carcinoma of the cervix.</p

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    A Visual Cryptography-Based Watermarking Approach for the Detection and Localization of Image Forgery

    No full text
    The usage of images in different fields has increased dramatically, especially in medical image analysis and social media. Many risks can threaten the integrity and confidentiality of digital images transmitted through the internet. As such, the preservation of the contents of these images is of the utmost importance for sensitive healthcare systems. In this paper, the researchers propose a block-based approach to protect the integrity of digital images by detecting and localizing forgeries. It employs a visual cryptography-based watermarking approach to provide the capabilities of forgery detection and localization. In this watermarking scheme, features and key and secret shares are generated. The feature share is constructed by extracting features from equal-sized blocks of the image by using a Walsh transform, a local binary pattern and a discrete wavelet transform. Then, the key share is generated randomly from each image block, and the secret share is constructed by applying the XOR operation between the watermark, feature share and key share. The CASIA V 1.0 and SIPI datasets were used to check the performance and robustness of the proposed method. The experimental results from these datasets revealed that the percentages of the precision, recall and F1 score classification indicators were approximately 97% for these indicators, while the percentages of the TAF and NC image quality indicators were approximately 97% and 96% after applying several known image processing and geometric attacks. Furthermore, the comparative experimental results with the state-of-art approaches proved the robustness and noticeable improvement in the proposed approach for the detection and localization of image forgeries in terms of classification and quality measures
    corecore