87 research outputs found
High-density Mapping Guided Pulmonary Vein Isolation for Treatment of Atrial Fibrillation-Two-year clinical outcome of a single center experience
Pulmonary vein isolation (PVI) as interventional treatment for atrial fibrillation (AF) aims to eliminate arrhythmogenic triggers from the PVs. Improved signal detection facilitating a more robust electrical isolation might be associated with a better outcome. This retrospective cohort study compared PVI procedures using a novel high-density mapping system (HDM) with improved signal detection vs. age-and sex-matched PVIs using a conventional 3D mapping system (COM). Endpoints comprised freedom from AF and procedural parameters. In total, 108 patients (mean age 63.9 +/- 11.2 years, 56.5% male, 50.9% paroxysmal AF) were included (n = 54 patients/group). Our analysis revealed that HDM was not superior regarding freedom from AF (mean follow-up of 494.7 +/- 26.2 days), with one- and two-year AF recurrence rates of 38.9%/46.5% (HDM) and 38.9%/42.2% (COM), respectively. HDM was associated with reduction in fluoroscopy times (18.8 +/- 10.6 vs. 29.8 +/- 13.4 min;p < 0.01) and total radiation dose (866.0 +/- 1003.3 vs. 1731.2 +/- 1978.4 cGy;p < 0.01) compared to the COM group. HDM was equivalent but not superior to COM with respect to clinical outcome after PVI and resulted in reduced fluoroscopy time and radiation exposure. These results suggest that HDM-guided PVI is effective and safe for AF ablation. Potential benefits in comparison to conventional mapping systems, e.g. arrhythmia recurrence rates, have to be addressed in randomized trials
Alteration of Endothelin 1, MCP-1 and Chromogranin A in patients with atrial fibrillation undergoing pulmonary vein isolation
Background: The relation between arrhythmias and stress is known. The aim of our current study was to elucidate whether plasma levels of previously described stress parameters are altered in highly symptomatic patients with atrial fibrillation (AF) per se and in patients undergoing ablation therapy by pulmonary vein isolation (PVI).
Methods: 96 patients with AF undergoing PVI were recruited. Plasma levels of Endothelin-1 (ET-1), MCP-1 and Chromogranin-A (CGA) were measured before and three months after ablation completed with clinical follow-up with respect to AF recurrence. Additionally, we examined 40 healthy age-and sex-matched volunteers as a reference.
Results: Symptomatic AF patients showed increased levels of ET-1 compared to healthy controls (2.62pg/ml vs. 1.57pg/ml;p<0.01). Baseline levels of ET-1 were higher in patients presenting with AF after PVI (2.96pg/ml vs. 2.57pg/ml;p = 0.02). The temporal comparison revealed decreased ET-1 levels in patients without (2.57pg/ml vs. 2.33pg/ml;p< 0.01) and unchanged ET-1 levels in patients with AF after PVI. Baseline MCP-1 was increased in AF patients vs. controls (268pg/ml vs. 227 pg/ml;p = 0.03). Both groups, with and without AF after PVI, showed an increase of MCP-1 compared to baseline (268pg/ml vs. 349pg/ml;p< 0.01;281pg/ml vs. 355pg/ml;p = 0.03). CGA was lower in AF patients compared to healthy controls (13.8ng/ml vs. 25.6ng/ml;p< 0.01). Over time patients without AF after PVI showed an increase of CGA (14.2ng/ml vs. 20.7ng/ml;p< 0.01). No change was observed in patients with AF after PVI.
Conclusion: Our study demonstrated dysregulated levels of ET-1, MCP-1 and CGA in symptomatic AF patients. We could demonstrate an association between ET-1 to presence or absence of AF. Furthermore, we could show that a decrease of ET-1 as well as an increase of CGA after PVI, representing a trend towards control cohort levels, were both associated with restoration of sinus rhythm. These results provide new insights into the role of stress-related biomarkers in AF and AF treatment by ablation therapy
ECG scoring for the evaluation of therapy-naïve cancer patients to predict cardiotoxicity
OBJECTIVE: To evaluate a new electrocardiographic (ECG) score reflecting domains of electrical and structural alterations in therapy-naïve cancer patients to assess their risk of cardiotoxicity. METHODS: We performed a retrospective analysis of 134 therapy-naïve consecutive cancer patients in our two university hospitals concerning four ECG score parameters: Contiguous Q-waves, markers of left ventricular (LV) hypertrophy, QRS duration and JTc prolongation. Cardiotoxicity was assessed after a short-term follow-up (up to 12 months). RESULTS: Of all the patients (n = 25), 19% reached 0 points, 50% (n = 67) reached 1 point, 25% (n = 33) reached 2 points, 5% (n = 7) reached 3 points and 0.7% reached 4 or 5 points (n = 1 respectively). The incidence of cardiotoxicity (n = 28 [21%]) increased with the ECG score, with 0 points at 0%, 1 point 7.5%, 2 points 55%, 3 points 71% and ≥3 points 50%. In the ROC (Receiver operating curves) analysis, the best cut-off for predicting cardiotoxicity was an ECG score of ≥2 points (sensitivity 82%, specificity 82%, AUC 0.84, 95% CI 0.77-0.92, p < 0.0001) which was then defined as a high-risk score. High-risk patients did not differ concerning their age, LV ejection fraction, classical cardiovascular risk factors or cardiac biomarkers compared to those with a low-risk ECG score. CONCLUSION: ECG scoring prior to the start of anti-cancer therapies may help to identify therapy-naïve cancer patients at a higher risk for the development of cardiotoxicity. SIMPLE SUMMARY: Due to improved survival upon effective anti-cancer therapies, the management of treatment-related side-effects is of increasing interest and importance. Cardiovascular side-effects of chemo-, targeted- and/or immunotherapies are common and can be harmful. To date, the identification of patients who could experience those cardiovascular side-effects prior to the anti-cancer therapy start is difficult. We show that the use of a simple electrocardiographic (ECG) score can help to predict the occurrence of cardiovascular toxicity of anti-cancer therapies
A Regional Reduction in Ito and IKACh in the Murine Posterior Left Atrial Myocardium Is Associated with Action Potential Prolongation and Increased Ectopic Activity.
BACKGROUND: The left atrial posterior wall (LAPW) is potentially an important area for the development and maintenance of atrial fibrillation. We assessed whether there are regional electrical differences throughout the murine left atrial myocardium that could underlie regional differences in arrhythmia susceptibility. METHODS: We used high-resolution optical mapping and sharp microelectrode recordings to quantify regional differences in electrical activation and repolarisation within the intact, superfused murine left atrium and quantified regional ion channel mRNA expression by Taqman Low Density Array. We also performed selected cellular electrophysiology experiments to validate regional differences in ion channel function. RESULTS: Spontaneous ectopic activity was observed during sustained 1Hz pacing in 10/19 intact LA and this was abolished following resection of LAPW (0/19 resected LA, P<0.001). The source of the ectopic activity was the LAPW myocardium, distinct from the pulmonary vein sleeve and LAA, determined by optical mapping. Overall, LAPW action potentials (APs) were ca. 40% longer than the LAA and this region displayed more APD heterogeneity. mRNA expression of Kcna4, Kcnj3 and Kcnj5 was lower in the LAPW myocardium than in the LAA. Cardiomyocytes isolated from the LAPW had decreased Ito and a reduced IKACh current density at both positive and negative test potentials. CONCLUSIONS: The murine LAPW myocardium has a different electrical phenotype and ion channel mRNA expression profile compared with other regions of the LA, and this is associated with increased ectopic activity. If similar regional electrical differences are present in the human LA, then the LAPW may be a potential future target for treatment of atrial fibrillation
Randomized Trial of Early Detection and Treatment of Postpartum Hemorrhage
Background: Delays in the detection or treatment of postpartum hemorrhage can result in complications or death. A blood-collection drape can help provide objective, accurate, and early diagnosis of postpartum hemorrhage, and delayed or inconsistent use of effective interventions may be able to be addressed by a treatment bundle.Methods: We conducted an international, cluster-randomized trial to assess a multicomponent clinical intervention for postpartum hemorrhage in patients having vaginal delivery. The intervention included a calibrated blood-collection drape for early detection of postpartum hemorrhage and a bundle of first-response treatments (uterine massage, oxytocic drugs, tranexamic acid, intravenous fluids, examination, and escalation), supported by an implementation strategy (intervention group). Hospitals in the control group provided usual care. The primary outcome was a composite of severe postpartum hemorrhage (blood loss, ≥1000 ml), laparotomy for bleeding, or maternal death from bleeding. Key secondary implementation outcomes were the detection of postpartum hemorrhage and adherence to the treatment bundle.Results: A total of 80 secondary-level hospitals across Kenya, Nigeria, South Africa, and Tanzania, in which 210,132 patients underwent vaginal delivery, were randomly assigned to the intervention group or the usual-care group. Among hospitals and patients with data, a primary-outcome event occurred in 1.6% of the patients in the intervention group, as compared with 4.3% of those in the usual-care group (risk ratio, 0.40; 95% confidence interval [CI], 0.32 to 0.50; P<0.001). Postpartum hemorrhage was detected in 93.1% of the patients in the intervention group and in 51.1% of those in the usual-care group (rate ratio, 1.58; 95% CI, 1.41 to 1.76), and the treatment bundle was used in 91.2% and 19.4%, respectively (rate ratio, 4.94; 95% CI, 3.88 to 6.28).Conclusions: Early detection of postpartum hemorrhage and use of bundled treatment led to a lower risk of the primary outcome, a composite of severe postpartum hemorrhage, laparotomy for bleeding, or death from bleeding, than usual care among patients having vaginal delivery
Randomized Trial of Early Detection and Treatment of Postpartum Hemorrhage
Background: Delays in the detection or treatment of postpartum hemorrhage can result in complications or death. A blood-collection drape can help provide objective, accurate, and early diagnosis of postpartum hemorrhage, and delayed or inconsistent use of effective interventions may be able to be addressed by a treatment bundle.Methods: We conducted an international, cluster-randomized trial to assess a multicomponent clinical intervention for postpartum hemorrhage in patients having vaginal delivery. The intervention included a calibrated blood-collection drape for early detection of postpartum hemorrhage and a bundle of first-response treatments (uterine massage, oxytocic drugs, tranexamic acid, intravenous fluids, examination, and escalation), supported by an implementation strategy (intervention group). Hospitals in the control group provided usual care. The primary outcome was a composite of severe postpartum hemorrhage (blood loss, ≥1000 ml), laparotomy for bleeding, or maternal death from bleeding. Key secondary implementation outcomes were the detection of postpartum hemorrhage and adherence to the treatment bundle.Results: A total of 80 secondary-level hospitals across Kenya, Nigeria, South Africa, and Tanzania, in which 210,132 patients underwent vaginal delivery, were randomly assigned to the intervention group or the usual-care group. Among hospitals and patients with data, a primary-outcome event occurred in 1.6% of the patients in the intervention group, as compared with 4.3% of those in the usual-care group (risk ratio, 0.40; 95% confidence interval [CI], 0.32 to 0.50; P<0.001). Postpartum hemorrhage was detected in 93.1% of the patients in the intervention group and in 51.1% of those in the usual-care group (rate ratio, 1.58; 95% CI, 1.41 to 1.76), and the treatment bundle was used in 91.2% and 19.4%, respectively (rate ratio, 4.94; 95% CI, 3.88 to 6.28).Conclusions: Early detection of postpartum hemorrhage and use of bundled treatment led to a lower risk of the primary outcome, a composite of severe postpartum hemorrhage, laparotomy for bleeding, or death from bleeding, than usual care among patients having vaginal delivery
Fire performance of phase change material enhanced plasterboard
Sustainable construction materials are increasingly being used to reduce the carbon footprint of modern buildings. These materials have the potential to change the fire dynamics of compartments by altering the compartment energy balance however there is little quantitative understanding of how these materials behave in the event of a real fire. The changes in fire dynamics may be due to increased fuel load in a compartment, reduced time to failure or promotion of flame spread. The objective of this research is to quantify how Phase Change Materials (PCMs) perform in realistic fire scenarios. It was found that a plasterboard product containing microencapsulated PCMs will behave similarly to a charring solid and have the potential to contribute significant fuel to a compartment fire but that they maintain integrity for the duration of flaming period. The critical heat flux for this product was determined in the cone calorimeter to be 17.5 ± 2.5 kW m−2, the peak heat release rate and mass loss rate ranged from 60.2 kW m−2 to 107 kW m−2 and 1.88 g s−1 m−2 to 8.47 g s−1 m−2 respectively for exposures between 20 kW m−2 and 70 kW m−2. Sample orientation was found to increase the peak heat release rate by up to 25%, whilst having little to no effect on the mass loss rate. These parameters, in addition to the in-depth temperature evolution and ignition properties, can be used as design criteria for balancing energy savings with quantified fire performance
- …