648 research outputs found

    Nucleosomes indicate the in vitro radiosensitivity of irradiated bronchoepithelial and lung cancer cells

    Get PDF
    Nucleosomes, which are typical cell death products, are elevated in the serum of cancer patients and are known to rapidly increase during radiotherapy. As both normal and malignant cells are damaged by irradiation, we investigated to which extent both cell types contribute to the release of nucleosomes. We cultured monolayers of normal bronchoepithelial lung cells (BEAS-2B, n = 18) and epithelial lung cancer cells (EPLC, n = 18), exposed them to various radiation doses (0, 10 and 30 Gy) and observed them for 5 days. Culture medium was changed every 24 h. Subsequently, nucleosomes were determined in the supernatant by the Cell Death Detection-ELISA(plus) ( Roche Diagnostics). Additionally, the cell number was estimated after harvesting the cells in a second preparation. After 5 days, the cell number of BEAS-2B cultures in the irradiated groups (10 Gy: median 0.03 x 10(6) cells/culture, range 0.02-0.08 x 10(6) cells/culture; 30 Gy: median 0.08 x 10(6) cells/culture, range 0.02-0.14 x 10(6) cells/culture) decreased significantly (10 Gy: p = 0.005; 30 Gy p = 0.005; Wilcoxon test) compared to the non-irradiated control group (median 4.81 x 10(6) cells/culture, range 1.50-9.54 x 10(6) cells/culture). Consistently, nucleosomes remained low in the supernatant of nonirradiated BEAS-2B. However, at 10 Gy, BEAS-2B showed a considerably increasing release of nucleosomes, with a maximum at 72 h ( before irradiation: 0.24 x 10(3) arbitrary units, AU, range 0.13-4.09 x 10(3) AU, and after 72 h: 1.94 x 10(3) AU, range 0.11-5.70 x 10(3) AU). At 30 Gy, the release was even stronger, reaching the maximum earlier (at 48 h, 11.09 x 10(3) AU, range 6.89-18.28 x 10(3) AU). In non-irradiated EPLC, nucleosomes constantly increased slightly. At 10 Gy, we observed a considerably higher release of nucleosomes in EPLC, with a maximum at 72 h (before irradiation: 2.79 x 10(3) AU, range 2.42-3.80 x 10(3) AU, and after 72 h: 7.16 x 10(3) AU, range 4.30-16.20 x 10(3) AU), which was more than 3.5 times higher than in BEAS-2B. At 30 Gy, the maximum (6.22 x 10(3) AU, range 5.13-9.71 x 10(3) AU) was observed already after 24 h. These results indicate that normal bronchoepithelial and malignant lung cancer cells contribute to the release of nucleosomes during irradiation in a dose-and time-dependent manner with cancer cells having a stronger impact at low doses. Copyright (C) 2004 S. Karger AG, Basel

    Region-Specific Microstructure in the Neonatal Ventricles of a Porcine Model

    Get PDF
    © 2018, Biomedical Engineering Society. The neonate transitions from placenta-derived oxygen, to supply from the pulmonary system, moments after birth. This requires a series of structural developments to divert more blood through the right heart and onto the lungs, with the tissue quickly remodelling to the changing ventricular workload. In some cases, however, the heart structure does not fully develop causing poor circulation and inefficient oxygenation, which is associated with an increase in mortality and morbidity. This study focuses on developing an enhanced knowledge of the 1-day old heart, quantifying the region-specific microstructural parameters of the tissue. This will enable more accurate mathematical and computational simulations of the young heart. Hearts were dissected from 12, 1-day-old deceased Yorkshire piglets (mass: 2.1–2.4kg, length: 0.38–0.51m), acquired from a breeding farm. Evans blue dye was used to label the heart equator and to demarcate the left and right ventricle free walls. Two hearts were used for three-dimensional diffusion-tensor magnetic resonance imaging, to quantify the fractional anisotropy (FA). The remaining hearts were used for two-photon excited fluorescence and second-harmonic generation microscopy, to quantify the cardiomyocyte and collagen fibril structures within the anterior and posterior aspects of the right and left ventricles. FA varied significantly across both ventricles, with the greatest in the equatorial region, followed by the base and apex. The FA in each right ventricular region was statistically greater than that in the left. Cardiomyocyte and collagen fibre rotation was greatest in the anterior wall of both ventricles, with less dispersion when compared to the posterior walls. In defining these key parameters, this study provides a valuable insight into the 1-day-old heart that will provide a valuable platform for further investigation the normal and abnormal heart using mathematical and computational models

    A splicing variant of TERT identified by GWAS interacts with menopausal estrogen therapy in risk of ovarian cancer

    Get PDF
    Menopausal estrogen-alone therapy (ET) is a well-established risk factor for serous and endometrioid ovarian cancer. Genetics also plays a role in ovarian cancer, which is partly attributable to 18 confirmed ovarian cancer susceptibility loci identified by genome-wide association studies. The interplay among these loci, ET use and ovarian cancer risk has yet to be evaluated. We analyzed data from 1,414 serous cases, 337 endometrioid cases and 4,051 controls across 10 case-control studies participating in the Ovarian Cancer Association Consortium (OCAC). Conditional logistic regression was used to determine the association between the confirmed susceptibility variants and risk of serous and endometrioid ovarian cancer among ET users and non-users separately and to test for statistical interaction. A splicing variant in TERT, rs10069690, showed a statistically significant interaction with ET use for risk of serous ovarian cancer (pint  = 0.013). ET users carrying the T allele had a 51% increased risk of disease (OR = 1.51, 95% CI 1.19-1.91), which was stronger for long-term ET users of 10+ years (OR = 1.85, 95% CI 1.28-2.66, pint  = 0.034). Non-users showed essentially no association (OR = 1.08, 95% CI 0.96-1.21). Two additional genomic regions harboring rs7207826 (C allele) and rs56318008 (T allele) also had significant interactions with ET use for the endometrioid histotype (pint  = 0.021 and pint  = 0.037, respectively). Hence, three confirmed susceptibility variants were identified whose associations with ovarian cancer risk are modified by ET exposure; follow-up is warranted given that these interactions are not adjusted for multiple comparisons. These findings, if validated, may elucidate the mechanism of action of these loci

    Association Between Menopausal Estrogen-Only Therapy and Ovarian Carcinoma Risk

    Get PDF
    OBJECTIVE: To describe the association between postmenopausal estrogen-only therapy use and risk of ovarian carcinoma, specifically with regard to disease histotype and duration and timing of use. METHODS: We conducted a pooled analysis of 906 women with ovarian carcinoma and 1,220 women in a control group; all 2,126 women included reported having had a hysterectomy. Ten population-based case-control studies participating in the Ovarian Cancer Association Consortium, an international consortium whose goal is to combine data from many studies with similar methods so reliable assessments of risk factors can be determined, were included. Self-reported questionnaire data from each study were harmonized and conditional logistic regression was used to examine estrogen-only therapy's histotype-specific and duration and recency of use associations. RESULTS: Forty-three and a half percent of the women in the control group reported previous use of estrogen-only therapy. Compared with them, current or recent estrogen-only therapy use was associated with an increased risk for the serous (51.4%, odds ratio [OR] 1.63, 95% confidence interval [CI] 1.27-2.09) and endometrioid (48.6%, OR 2.00, 95% CI 1.17-3.41) histotypes. In addition, statistically significant trends in risk according to duration of use were seen among current or recent postmenopausal estrogen-only therapy users for both ovarian carcinoma histotypes (Ptrend<.001 for serous and endometrioid). Compared with women in the control group, current or recent users for 10 years or more had increased risks of serous ovarian carcinoma (36.8%, OR 1.73, 95% CI 1.26-2.38) and endometrioid ovarian carcinoma (34.9%, OR 4.03, 95% CI 1.91-8.49). CONCLUSION: We found evidence of an increased risk of serous and endometrioid ovarian carcinoma associated with postmenopausal estrogen-only therapy use, particularly of long duration. These findings emphasize that risk may be associated with extended estrogen-only therapy use

    Giant spin Hall effect in graphene grown by chemical vapour deposition

    Get PDF
    Advances in large-area graphene synthesis via chemical vapour deposition on metals like copper were instrumental in the demonstration of graphene-based novel, wafer-scale electronic circuits and proof-of-concept applications such as flexible touch panels. Here, we show that graphene grown by chemical vapour deposition on copper is equally promising for spintronics applications. In contrast to natural graphene, our experiments demonstrate that chemically synthesized graphene has a strong spin-orbit coupling as high as 20 meV giving rise to a giant spin Hall effect. The exceptionally large spin Hall angle ∟0.2 provides an important step towards graphene-based spintronics devices within existing complementary metal-oxide-semiconductor technology. Our microscopic model shows that unavoidable residual copper adatom clusters act as local spin-orbit scatterers and, in the resonant scattering limit, induce transverse spin currents with enhanced skew-scattering contribution. Our findings are confirmed independently by introducing metallic adatoms-copper, silver and gold on exfoliated graphene samples

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Search for squarks and gluinos in events with isolated leptons, jets and missing transverse momentum at s√=8 TeV with the ATLAS detector

    Get PDF
    The results of a search for supersymmetry in final states containing at least one isolated lepton (electron or muon), jets and large missing transverse momentum with the ATLAS detector at the Large Hadron Collider are reported. The search is based on proton-proton collision data at a centre-of-mass energy s√=8 TeV collected in 2012, corresponding to an integrated luminosity of 20 fb−1. No significant excess above the Standard Model expectation is observed. Limits are set on supersymmetric particle masses for various supersymmetric models. Depending on the model, the search excludes gluino masses up to 1.32 TeV and squark masses up to 840 GeV. Limits are also set on the parameters of a minimal universal extra dimension model, excluding a compactification radius of 1/R c = 950 GeV for a cut-off scale times radius (ΛR c) of approximately 30

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …
    corecore