42 research outputs found

    The Noncommutative Harmonic Oscillator based in Simplectic Representation of Galilei Group

    Full text link
    In this work we study symplectic unitary representations for the Galilei group. As a consequence the Schr\"odinger equation is derived in phase space. The formalism is based on the non-commutative structure of the star-product, and using the group theory approach as a guide a physical consistent theory in phase space is constructed. The state is described by a quasi-probability amplitude that is in association with the Wigner function. The 3D harmonic oscillator and the noncommutative oscillator are studied in phase space as an application, and the Wigner function associated to both cases are determined.Comment: 7 pages,no figure

    The fate of steroid estrogens: Partitioning during wastewater treatment and onto river sediments

    Get PDF
    This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2010 Springer Science+Business Media B.V.The partitioning of steroid estrogens in wastewater treatment and receiving waters is likely to influence their discharge to, and persistence in, the environment. This study investigated the partitioning behaviour of steroid estrogens in both laboratory and field studies. Partitioning onto activated sludge from laboratory-scale Husmann units was rapid with equilibrium achieved after 1 h. Sorption isotherms and Kd values decreased in the order 17α-ethinyl estradiol > 17α-estradiol > estrone > estriol without a sorption limit being achieved (1/n >1). Samples from a wastewater treatment works indicated no accumulation of steroid estrogens in solids from primary or secondary biological treatment, however, a range of steroid estrogens were identified in sediment samples from the River Thames. This would indicate that partitioning in the environment may play a role in the long-term fate of estrogens, with an indication that they will be recalcitrant in anaerobic conditions.EPSR

    Sleep complaints among Brazilian senior citizens from municipalities with different Human Development Indices

    Get PDF
    PURPOSE: To compare the occurrence of sleep complaints among senior citizens resident in the local communities of two municipalities with differing Human Development Indices (HDIs): Campinas, State of São Paulo (IDH = 0.852) and Parnaíba, State of Piauí (IDH = 0.674). METHOD: Descriptive study as part of the multicentric project going by the name of Frailty among Brazilian Senior Citizens (Fragilidade em Idosos Brasileiros - FIBRA). A total of 988 senior citizens were analysed, making use of a social and demographic questionnaire about sleep problems (Nottingham Health Profile); questions about naps (Minnesota Leisure Activity Questionnaire). The Chi-Square and Mann-Whitney tests were used in the analysis of the data, at a significance level of 5% (pOBJETIVO: comparar la ocurrencia de quejas de sueño en mayores residentes en la comunidad de dos municipios con diferentes Índices de Desarrollo Humano (IDH): Campinas (IDH=0,852) y Parnaíba (IDH=0,674). MÉTODO: estudio descriptivo parte integrante del proyecto multicéntrico Fragilidad en Mayores Brasileños (FIBRA). Fueron evaluados 988 de edad, utilizándose cuestionario sociodemográfico, cuestiones sobre quejas de sueño (Perfil de Salud de Nottingham); cuestiones sobre sueños (Minnesota Leisure Activity Questionnaire). Los testes Jue-cuadrado y Mann Whitney fueron utilizados en el análisis de datos, con nivel de significancia del 5% (pOBJETIVO: comparar a ocorrência de queixas de sono em idosos residentes na comunidade de dois municípios com diferentes índices de desenvolvimento humano (IDH): Campinas, SP, (IDH=0,852) e Parnaíba, PI, (IDH=0,674). MÉTODO: estudo descritivo, parte integrante do projeto multicêntrico Fragilidade em Idosos Brasileiros (Fibra). Foram avaliados 988 idosos, utilizando-se questionário sociodemográfico, questões sobre queixas de sono (Perfil de Saúde de Nottingham); questões sobre cochilo (Minnesota Leisure Activity Questionnaire). Os testes qui-quadrado e Mann-Whitney foram utilizados na análise de dados, com nível de significância de 5% (p<0,05). RESULTADOS: os idosos de Parnaíba apresentaram maiores porcentagens de queixas de sono se comparados aos idosos de Campinas. Houve associação significativa entre município e número de queixas de sono, sono não restaurador, despertar precoce, dificuldade para manter e para iniciar o sono. CONCLUSÃO: os enfermeiros devem intervir na promoção da saúde com ações que minimizem ou previnam esses problemas relativos ao sono

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Performance of CMS muon reconstruction in cosmic-ray events

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10 GeV/c to about 1% at 500 GeV/c.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    corecore