38 research outputs found

    Systematic review and meta-analysis of the metabolic effects of modified-release hydrocortisone versus standard glucocorticoid replacement therapy in adults with adrenal insufficiency

    Get PDF
    Context Published studies exploring the metabolic effects of Modified‐Release Hydrocortisone (MR‐HC) replacement in patients with adrenal insufficiency (AI). Objective To compare metabolic effects of MR‐HC with Standard Glucocorticoid (SG) replacement in adults with AI. Randomised control trials (RCTs) were meta‐analysed; non‐RCT studies described narratively with critical appraisal. Data sources PubMed/Medline, EMBASE, CINAHL and CENTRAL were searched to identify relevant articles, published before Aug 2019. Study selection All study types that reported metabolic profile (including anthropometric, glucose and lipid‐related parameters), on patients switched from SG to MR‐HC replacement. Following independent screening from two reviewers, 390 studies were identified, of which 9 studies were included for review (RCT, n=2; non‐RCT, n=7). Data extraction Two independent reviewers assessed each paper for bias and data extraction. Results Meta‐analysis from RCTs (n=2), 104 patients were switched from SG to MR‐HC replacement. Combining treatment effects, at 3‐months post‐therapy switch there was significant reduction in body weight (‐0.82kg; 95% CI: ‐1.24kg to ‐0.40kg; p<0.001) and HbA1c (‐0.13%; 95% CI: ‐0.214% to ‐0.045%; p=0.003). In the sub‐group with Diabetes Mellitus (DM), reduction in HbA1C was more pronounced (‐0.52%; 95% CI: ‐0.82% to ‐0.23%; p<0.001). Non‐RCT studies showed improved anthropometric measures and glucose metabolism up to 48‐months following switch from SG to MR‐HC replacement. Conclusions In adults with AI, replacement with MR‐HC associates with significant improvements in anthropometric measurements and HbA1c compared with SG replacement, particularly those with DM

    Early metabolic benefits of switching hydrocortisone to modified release hydrocortisone in adult adrenal insufficiency

    Get PDF
    Purpose: To compare metabolic effects of modified release hydrocortisone (MR-HC) with standard hydrocortisone (HC) therapies in adults with Adrenal Insufficiency (AI). Methods: Adult patients (n = 12) with AI, established on HC therapy, were recruited from Endocrinology clinics at University Hospitals Coventry and Warwickshire (UHCW), UK. Baseline (HC) metabolic assessments included fasting serum HbA1C, lipid and thyroid profiles, accurate measures of body composition (BodPod), and 24-h continuous measures of energy expenditure including Sleeping Metabolic Rate (SMR) using indirect calorimetry within the Human Metabolism Research Unit, UHCW. All participants then switched HC to MR-HC with repeat (MR-HC) metabolic assessments at 3 months. Paired-sample t-tests were used for data comparisons between HC and MR-HC assessments: P-value <0.05 was considered significant. Results: Following exclusion of 2 participants, analyses were based on 10 participants. Compared with baseline HC data, following 3 months of MR-HC therapy mean fat mass reduced significantly by −3.2 kg (95% CI: −6.0 to −0.4). Mean (SD) baseline HC fat mass vs repeat MR-HC fat mass: 31.9 kg (15.2) vs 28.7 kg (12.8) respectively, P = 0.03. Mean SMR increased significantly by +77 kcal/24 h (95% CI: 10–146). Mean (SD) baseline HC SMR vs repeat MR-HC SMR: 1,517 kcal/24 h (301) vs 1,594 kcal/24 h (344) respectively, P = 0.03. Mean body fat percentage reduced significantly by −3.4% (95% CI: −6.5 to −0.2). Other measures of body composition, energy expenditure, and biochemical analytes were equivalent between HC and MR-HC assessments. Conclusions: In adults with AI, switching from standard HC to MR-HC associates with early metabolic benefits of reduced fat mass and increased SMR

    Comparative analytical performance of multiple plasma Aβ42 and Aβ40 assays and their ability to predict positron emission tomography amyloid positivity

    Get PDF
    INTRODUCTION: This report details the approach taken to providing a dataset allowing for analyses on the performance of recently developed assays of amyloid beta (Aβ) peptides in plasma and the extent to which they improve the prediction of amyloid positivity. METHODS: Alzheimer's Disease Neuroimaging Initiative plasma samples with corresponding amyloid positron emission tomography (PET) data were run on six plasma Aβ assays. Statistical tests were performed to determine whether the plasma Aβ measures significantly improved the area under the receiver operating characteristic curve for predicting amyloid PET status compared to age and apolipoprotein E (APOE) genotype. RESULTS: The age and APOE genotype model predicted amyloid status with an area under the curve (AUC) of 0.75. Three assays improved AUCs to 0.81, 0.81, and 0.84 (P < .05, uncorrected for multiple comparisons). DISCUSSION: Measurement of Aβ in plasma contributes to addressing the amyloid component of the ATN (amyloid/tau/neurodegeneration) framework and could be a first step before or in place of a PET or cerebrospinal fluid screening study. HIGHLIGHTS: The Foundation of the National Institutes of Health Biomarkers Consortium evaluated six plasma amyloid beta (Aβ) assays using Alzheimer's Disease Neuroimaging Initiative samples. Three assays improved prediction of amyloid status over age and apolipoprotein E (APOE) genotype. Plasma Aβ42/40 predicted amyloid positron emission tomography status better than Aβ42 or Aβ40 alone

    The potential to expand antiretroviral therapy by improving health facility efficiency: evidence from Kenya, Uganda, and Zambia.

    Get PDF
    BACKGROUND: Since 2000, international funding for HIV has supported scaling up antiretroviral therapy (ART) in sub-Saharan Africa. However, such funding has stagnated for years, threatening the sustainability and reach of ART programs amid efforts to achieve universal treatment. Improving health system efficiencies, particularly at the facility level, is an increasingly critical avenue for extending limited resources for ART; nevertheless, the potential impact of increased facility efficiency on ART capacity remains largely unknown. Through the present study, we sought to quantify facility-level technical efficiency across countries, assess potential determinants of efficiency, and predict the potential for additional ART expansion. METHODS: Using nationally-representative facility datasets from Kenya, Uganda and Zambia, and measures adjusting for structural quality, we estimated facility-level technical efficiency using an ensemble approach that combined restricted versions of Data Envelopment Analysis and Stochastic Distance Function. We then conducted a series of bivariate and multivariate regression analyses to evaluate possible determinants of higher or lower technical efficiency. Finally, we predicted the potential for ART expansion across efficiency improvement scenarios, estimating how many additional ART visits could be accommodated if facilities with low efficiency thresholds reached those levels of efficiency. RESULTS: In each country, national averages of efficiency fell below 50 % and facility-level efficiency markedly varied. Among facilities providing ART, average efficiency scores spanned from 50 % (95 % uncertainty interval (UI), 48-62 %) in Uganda to 59 % (95 % UI, 53-67 %) in Zambia. Of the facility determinants analyzed, few were consistently associated with higher or lower technical efficiency scores, suggesting that other factors may be more strongly related to facility-level efficiency. Based on observed facility resources and an efficiency improvement scenario where all facilities providing ART reached 80 % efficiency, we predicted a 33 % potential increase in ART visits in Kenya, 62 % in Uganda, and 33 % in Zambia. Given observed resources in facilities offering ART, we estimated that 459,000 new ART patients could be seen if facilities in these countries reached 80 % efficiency, equating to a 40 % increase in new patients. CONCLUSIONS: Health facilities in Kenya, Uganda, and Zambia could notably expand ART services if the efficiency with which they operate increased. Improving how facility resources are used, and not simply increasing their quantity, has the potential to substantially elevate the impact of global health investments and reduce treatment gaps for people living with HIV

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe

    The effect of disposable infection control barriers and physical damage on the power output of light curing units and light curing tips

    No full text
    This study investigated the effects that disposable infection control barriers and physical damage through use had on the power output from dental light curing units (LCUs) and light curing tips (LCTs). Five disposable infection control barriers were tested on a number of LCUs and LCTs. Testing involved the repeated measurement of power output of LCUs and LCTs on a radiometer. Two of the barriers tested caused statistically significant reductions in the mean light output intensity when compared to the no barrier control groups. One barrier type reduced the power output by 30 to 40%. It was also noted that physical damage to the LCTs affected power output by between 20 and 30%, which was then further reduced by the disposable barrier. This study showed that three of the five disposable infection control barriers had little effect on the overall efficiency of the power output of the LCUs. It also showed that physical damage to LCUs and LCTs can affect power output significantly. Infection control measures should be carefully considered before use to avoid undue effects on power output delivered from the LCUs/LCTs to ensure that the degree of polymerisation within the resin-based composite and curing efficiency are not affected unduly. © 2011 Macmillan Publishers Limited. All rights reserved

    Motilin fluctuations in healthy volunteers determined by liquid chromatography mass spectrometry

    No full text
    IntroductionMotilin is a hormone secreted by specialised enteroendocrine cells in the small intestine, and is known to modulate gastrointestinal motility in humans, regulating the migratory motor complex. It is understudied at least in part due to the lack of commercially available immunoassays.MethodA multiplexed liquid chromatography mass spectrometry (LC-MS/MS) method was optimised to measure motilin, insulin, C-peptide, GIP (1–42) and GIP (3–42). Corresponding active ghrelin concentrations were determined by immunoassay. Ten healthy volunteers with no prior history of gastroenterological or endocrine condition attended after overnight fast and had blood samples taken every 15 minutes for 4 hours whilst continuing to fast, and then further sampling for 2 hours following a liquid mixed meal. Hunger scores were taken at each time point using a visual analogue scale. Normal bowel habit was confirmed by 1 week stool diary.ResultsMotilin levels fluctuated in the fasting state with an average period between peaks of 109.5 mins (SD:30.0), but with no evidence of a relationship with either ghrelin levels or hunger scores. The mixed meal interrupted cyclical motilin fluctuations, increased concentrations of motilin, insulin, C-peptide, GIP(1-42) and GIP(3-42), and suppressed ghrelin levels.DiscussionThis study highlights the utility of LC-MS/MS for parallel measurement of motilin alongside other peptide hormones, and supports previous reports of the cyclical nature of motilin levels in the fasting state and interruption with feeding. This analytical method has utility for further clinical studies into motilin and gut hormone physiology in human volunteers
    corecore