1,261 research outputs found

    Goat Milk Based Infant Formula in Newborns:A Double-Blind Randomized Controlled Trial on Growth and Safety.

    Get PDF
    Objectives: We aimed to determine the growth and safety parameters in newborns fed a goat milk based infant formula (GMF) using a randomized double-blind trial, in which a cow milk formula (CMF) served as a control and a breast fed (BF) group as a reference. Methods: Healthy term infants (n = 218) aged up to 14 days were recruited from 25 European study centers and randomized to GMF or CMF. Weight, length, head circumference were measured at baseline, and at 14, 28, 56, 84, and 112 days at the study clinics. Adverse events were recorded and stool characteristics, reflux, fussiness, colic, and flatulence were self-reported by parents in 3-day diaries. Anthropometric measurements were transformed to WHO standardized age- and sex-adjusted z-scores. Analyses of covariance and linear mixed modeling were used to statistically analyze growth, while adjusting for potential confounders when studying the breast-fed group (n = 86). Results: Comparing the GMF to the CMF group, weight gain [mean difference 227.8 g (95% CI -16.6 to -439.0)] and z-scores for anthropometric measurements were similar after 112 days intervention. Infant formula groups showed greater mean (SD) weight z-scores than the BF group from 84 days onwards (GMF: 0.28 (0.84), CMF: 0.12 (0.88), BF -0.19 (1.02), P < 0.05), whereas length and head circumference z-scores were similar. Incidences of serious adverse events and reflux, fussiness, colic, and flatulence were similar among the three groups. Conclusion: Our data demonstrate that GMF provides adequate growth, has a good tolerability, and is safe to use in infants

    A dynamic flow model mimicking duodenoscope reprocessing after bacterial contamination for translational research

    Get PDF
    OBJECTIVE: Duodenoscopy-associated infections and outbreaks are reported globally despite strict adherence to duodenoscope reprocessing protocols. Therefore, new developments in the reprocessing procedure are needed. DESIGN: We evaluated a novel dynamic flow model for an additional cleaning step between precleaning and manual cleaning in the reprocessing procedure. METHODS: A parallel plate flow chamber with a fluorinated ethylene propylene bottom plate was used to mimic the duodenoscope channels. The flow chamber was inoculated with a suspension containing Klebsiella pneumoniae to simulate bacterial contamination during a duodenoscopic procedure. After inoculation the flow chamber was flushed with a detergent mimicking precleaning. Subsequently the flow chamber was subjected to different interventions: flow with phosphate-buffered saline (PBS), flow with 2 commercial detergents, flow with sodium dodecyl sulfate with 3 different concentrations, and flow with microbubbles. Adhering bacteria were counted using phase-contrast microscopy throughout the experiment, and finally, bacterial viability was assessed. RESULTS: During precleaning both PBS and 1% (v/v) Neodisher Mediclean Forte were able to desorb bacteria, but neither proved superior. After precleaning only sodium dodecyl sulfate could desorb bacteria. CONCLUSIONS: Flushing during precleaning is an essential step for reducing adhering luminal bacteria, and sodium dodecyl sulfate is a promising detergent for bacterial desorption from duodenoscope channels after precleaning

    The aortic root in repaired tetralogy of Fallot:Serial measurements and impact of losartan treatment

    Get PDF
    Background: Aortic root dilatation is common in adults with repaired tetralogy of Fallot (rTOF) and might lead to aortic dissection. However, little is known on progression of aortic dilatation and the effect of pharmaceutical treatment. This study aims to determine factors associated with aortic growth and investigate effects of losartan. Methods and results: We performed a prespecified analysis from the 1:1 randomized, double-blind REDEFINE trial. Aortic root diameters were measured at baseline and after 2.0 ± 0.3 years of follow-up using cardiovascular magnetic resonance (CMR) imaging. A total of 66 patients were included (68% men, age 40 ± 12 years, baseline aortic root 37 ± 6 mm, 32% aortic dilatation (>40 mm)). There was a trend towards slow aortic root growth (+0.6 ± 2.3 mm after two years, p = 0.06) (n = 60). LV stroke volume was the only factor associated with both a larger baseline aortic root (ÎČ: 0.09 mm/ml (95% C.I.:0.02, 0.15), p = 0.010) and with aortic growth during follow-up (ÎČ: 0.04 mm/ml (95% C.I.:0.005, 0.066), p = 0.024), after correction for age, sex, and body surface area using linear regression analysis. No treatment effect of losartan was found (p = 0.17). Conclusions: Aortic root dilatation was present in about one-third of rTOF patients. A larger LV stroke volume was associated with both a larger baseline aortic root and ongoing growth. Our findings provide no arguments for lower aortic diameter thresholds for prophylactic surgery compared to the general population

    System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS

    Get PDF
    An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last four years. This spectrometer will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip Chambers (CSC) for precision tracking, Resistive Plate Chambers (RPCs) for triggering in the barrel and Thin Gap Chambers (TGCs) for triggering in the end-cap region. The test set-up emulates one projective tower of the barrel (six MDT chambers and six RPCs) and one end-cap octant (six MDT chambers, A CSC and three TGCs). The barrel and end-cap stands have also been equipped with optical alignment systems, aiming at a relative positioning of the precision chambers in each tower to 30-40 micrometers. In addition to the performance of the detectors and the alignment scheme, many other systems aspects of the ATLAS muon spectrometer have been tested and validated with this setup, such as the mechanical detector integration and installation, the detector control system, the data acquisition, high level trigger software and off-line event reconstruction. Measurements with muon energies ranging from 20 to 300 GeV have allowed measuring the trigger and tracking performance of this set-up, in a configuration very similar to the final spectrometer. A special bunched muon beam with 25 ns bunch spacing, emulating the LHC bunch structure, has been used to study the timing resolution and bunch identification performance of the trigger chambers. The ATLAS first-level trigger chain has been operated with muon trigger signals for the first time

    Measurements of Higgs boson production and couplings in diboson final states with the ATLAS detector at the LHC

    Get PDF
    Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H →γ Îł, H → Z Z∗ →4l and H →W W∗ →lÎœlÎœ. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of √s = 7 TeV and √s = 8 TeV, corresponding to an integrated luminosity of about 25 fb−1. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined ïŹts probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson

    Standalone vertex ïŹnding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011

    Search for squarks and gluinos in events with isolated leptons, jets and missing transverse momentum at s√=8 TeV with the ATLAS detector

    Get PDF
    The results of a search for supersymmetry in final states containing at least one isolated lepton (electron or muon), jets and large missing transverse momentum with the ATLAS detector at the Large Hadron Collider are reported. The search is based on proton-proton collision data at a centre-of-mass energy s√=8 TeV collected in 2012, corresponding to an integrated luminosity of 20 fb−1. No significant excess above the Standard Model expectation is observed. Limits are set on supersymmetric particle masses for various supersymmetric models. Depending on the model, the search excludes gluino masses up to 1.32 TeV and squark masses up to 840 GeV. Limits are also set on the parameters of a minimal universal extra dimension model, excluding a compactification radius of 1/R c = 950 GeV for a cut-off scale times radius (ΛR c) of approximately 30

    Measurement of the top quark-pair production cross section with ATLAS in pp collisions at \sqrt{s}=7\TeV

    Get PDF
    A measurement of the production cross-section for top quark pairs(\ttbar) in pppp collisions at \sqrt{s}=7 \TeV is presented using data recorded with the ATLAS detector at the Large Hadron Collider. Events are selected in two different topologies: single lepton (electron ee or muon Ό\mu) with large missing transverse energy and at least four jets, and dilepton (eeee, ΌΌ\mu\mu or eΌe\mu) with large missing transverse energy and at least two jets. In a data sample of 2.9 pb-1, 37 candidate events are observed in the single-lepton topology and 9 events in the dilepton topology. The corresponding expected backgrounds from non-\ttbar Standard Model processes are estimated using data-driven methods and determined to be 12.2±3.912.2 \pm 3.9 events and 2.5±0.62.5 \pm 0.6 events, respectively. The kinematic properties of the selected events are consistent with SM \ttbar production. The inclusive top quark pair production cross-section is measured to be \sigmattbar=145 \pm 31 ^{+42}_{-27} pb where the first uncertainty is statistical and the second systematic. The measurement agrees with perturbative QCD calculations.Comment: 30 pages plus author list (50 pages total), 9 figures, 11 tables, CERN-PH number and final journal adde
    • 

    corecore