210 research outputs found

    Pleural Effusion after Percutaneous Radiofrequency Ablation for Hepatic Malignancies

    Get PDF
    AbstractBackground and AimsRadiofrequency ablation (RFA) can play an important role in the treatment of primary or metastatic liver tumors. Currently, percutaneous RFA is generally regarded as a safe, effective, and minimally invasive procedure. This study aimed to evaluate the presence and course of pleural effusion after monopolar RFA.MethodsFrom October 2008 to July 2013, a total of 54 patients (28 male and 26 female, mean age 65.2) treated with monopolar RFA were included in our study. 47 patients were diagnosed with hepatocellular carcinoma, 4 patients with hepatic metastasis, and 3 patients had other diagnoses. There were a total of 115 sessions of treatment and 199 liver tumors to be treated (1.73 ± 1.02 tumors treated per session). The tumor size ranged from 0.8 cm to 5.0 cm (mean 2.31 cm, standard deviation 1.04 cm). Thereafter, a follow-up ultrasound was performed within 24 hours subsequent to ablation to evaluate the presence of pleural effusion. The degree of pleural effusion was assessed by chest X-ray.ResultsFifteen (13.0%) treatment sessions in 14 patients showed right-sided pleural effusion after ablations. One patient had a large amount of effusion, while other patients manifested a minimal to small amount of effusion. There were 5 patients that experienced delayed resolution of pleural effusion; one patient (0.87%) had a minimal amount of pleural effusion even after one month. Overall, there was no pneumothorax, or periprocedural morality. Age, gender, tumor numbers, tumor sizes, and complete ablation of target tumors were similar among groups presenting with or without pleural effusion. Tumor locations associated with S78 segments abutting the diaphragm or right lobe of the liver were not associated with development of pleural effusion. Only the duration of ablation time had a marginal trend toward significance (p = 0.051).ConclusionsThe transient appearance of right-sided pleural effusion after percutaneous RFA for hepatic malignancies was not infrequent. However, refractory pleural effusion was rare

    Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with hepatocellular carcinoma (HCC) and portal vein thrombosis (PVT).</p> <p>Methods</p> <p>Nine patients with unresectable HCC and PVT underwent step and shoot coplanar IMRT with intent to deliver 46 - 54 Gy to the tumor and portal vein. The volume of liver received 30Gy was set to keep less than 30% of whole normal liver (V30 < 30%). The mean dose to at least one side of kidney was kept below 23 Gy, and 50 Gy as for stomach. The maximum dose was kept below 47 Gy for spinal cord. Several parameters including mean hepatic dose, percent volume of normal liver with radiation dose at X Gy (Vx), uniformity index, conformal index, and doses to organs at risk were evaluated from the dose-volume histogram.</p> <p>Results</p> <p>HT provided better uniformity for the planning-target volume dose coverage than both IMRT techniques. The noncoplanar IMRT technique reduces the V10 to normal liver with a statistically significant level as compared to HT. The constraints for the liver in the V30 for coplanar IMRT vs. noncoplanar IMRT vs. HT could be reconsidered as 21% vs. 17% vs. 17%, respectively. When delivering 50 Gy and 60-66 Gy to the tumor bed, the constraints of mean dose to the normal liver could be less than 20 Gy and 25 Gy, respectively.</p> <p>Conclusion</p> <p>Noncoplanar IMRT and HT are potential techniques of radiation therapy for HCC patients with PVT. Constraints for the liver in IMRT and HT could be stricter than for 3DCRT.</p

    Electromagnetic Wave Theory and Applications

    Get PDF
    Contains table of contents for Section 3, reports on three research projects and a list of publications.California Institute of Technology/Jet Propulsion Laboratory Contract 959548National Aeronautics and Space Administration Grant NAGW-1617National Aeronautics and Space Administration Grant Contract 958461U.S. Navy - Office of Naval Research Grant N00014-92-J-1616U.S. Navy - Office of Naval Research Grant N00014-92-J-4098Digital Equipment Corporation AGMT DTD 11/16/93Joint Services Electronics Program Contract DAAL03-92-C-0001Joint Services Electronics Program Grant DAAH04-95-1-0038MIT Lincoln Laboratory P.O. No. BX-5424U.S. Navy - Office of Naval Research Grant N00014-90-J-1002U.S. Navy - Office of Naval Research Grant N00014-89-J-1019DEMACO Agreement 11/15/93Federal Aviation Administration Grant 94-G-007U.S. Army Cold Regions Research and Engineering Laboratory Contract DACA89-93-K-000

    Electromagnetic Wave Theory and Applications

    Get PDF
    Contains table of contents for Section 3 and reports on four research projects.California Institute of Technology/Jet Propulsion Laboratory Agreement 959548National Aeronautics and Space Administration Grant NAGW-1617National Aeronautics and Space Administration Agreement 958461U.S. Navy - Office of Naval Research Grant N00014-89-J-1107U.S. Navy - Office of Naval Research Grant N00014-92-J-1616U.S. Navy - Office of Naval Research Grant N00014-92-J-4098Digital Equipment CorporationJoint Services Electronics Program Contract DAAL03-92-C-0001U.S. Navy - Office of Naval Research Agreement N00014-90-J-1002U.S. Navy - Office of Naval Research Agreement N00014-89-J-1019DEMACOU.S. Army Cold Regions Research and Engineering Laboratory Contract DACA89-93-K-0009U.S. Department of Transportation Agreement DTRS-57-92-C-00054TTD1Advanced Research Projects Agency/Consortium for Superconducting Electronics Contract MDA972-90-C-0021National Science Foundation Fellowship MIP 88-58764National Science Foundatio

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Search for High-Mass Resonances Decaying to τν in pp Collisions at √s=13 TeV with the ATLAS Detector

    Get PDF
    A search for high-mass resonances decaying to τν using proton-proton collisions at √s=13 TeV produced by the Large Hadron Collider is presented. Only τ-lepton decays with hadrons in the final state are considered. The data were recorded with the ATLAS detector and correspond to an integrated luminosity of 36.1 fb−1. No statistically significant excess above the standard model expectation is observed; model-independent upper limits are set on the visible τν production cross section. Heavy W′ bosons with masses less than 3.7 TeV in the sequential standard model and masses less than 2.2–3.8 TeV depending on the coupling in the nonuniversal G(221) model are excluded at the 95% credibility level

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    Measurement of the cross section for inclusive isolated-photon production in pp collisions at √s=13TeV using the ATLAS detector

    Get PDF
    Inclusive isolated-photon production in pp collisions at a centre-of-mass energy of 13TeVis studied with the ATLAS detector at the LHC using a data set with an integrated luminosity of 3.2fb−1. The cross section is measured as a function of the photon transverse energy above 125GeVin different regions of photon pseudorapidity. Next-to-leading-order perturbative QCD and Monte Carlo event-generator predictions are compared to the cross-section measurements and provide an adequate description of the data

    Measurement of differential cross sections and W + /W − cross-section ratios for W boson production in association with jets at √s =8 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the W boson production cross section and the W + /W − cross-section ratio, both in association with jets, in proton--proton collisions at s √ =8 TeV with the ATLAS experiment at the Large Hadron Collider. The measurement is performed in final states containing one electron and missing transverse momentum using data corresponding to an integrated luminosity of 20.2 fb −1 . Differential cross sections for events with one or two jets are presented for a range of observables, including jet transverse momenta and rapidities, the scalar sum of transverse momenta of the visible particles and the missing transverse momentum in the event, and the transverse momentum of the W boson. For a subset of the observables, the differential cross sections of positively and negatively charged W bosons are measured separately. In the cross-section ratio of W + /W − the dominant systematic uncertainties cancel out, improving the measurement precision by up to a factor of nine. The observables and ratios selected for this paper provide valuable input for the up quark, down quark, and gluon parton distribution functions of the proto
    corecore