2,444 research outputs found

    Improved Healing of Pressure Ulcers Using Dermapulse, A New Electrical Stimulation Device

    Get PDF
    A double-blind, clinical study of pulsed electrical stimulation using the DermapulseÂŽ device was carried out on 40 pressure ulcers, randomized to receive either active (stim) or sham treatment. Electrodes were placed over saline-moistened gauze on the ulcers. An electrical current of 35mA was delivered to the wound tissues at a frequency of 128 pulses per second. Polarity was negative until the wound debrided, then alternated from .positive to negative every three days. Ulcers were treated for 30 minutes twice daily for four weeks, after which sham patients could cross over to active treatment, and stim patients could continue active treatment. Ulcer healing was determined by measuring the length and width of the ulcer and calculating the L x W product. The same clinicians measured the ulcers each week, were kept blinded to treatment group, and were not the same persons who applied the treatment. Nine centers treated 40 ulcers (19 sham and 21 stim). Analysis of the characteristics of the patients, the ulcers, and concomitant wound care by both univariate and multivariate analyses showed comparability of the groups. After four weeks, the stim ulcers healed more than twice as much as the sham ulcers (49.8% vs. 23.4%; (p = 0.042). The stim ulcers healed 12.5% per week compared to 5.8% for the sham group. In the 15 crossover patients, four weeks of active stimulation caused nearly four times as much healing as their four weeks of sham treatment (47.9% vs. 13.4%; p = 0.012). By the last week of-active stimulation they had healed an average of 64%, and complete healing occurred in 40% of these ulcers after an average of nine weeks. Seventeen of the active treatment ulcers had extended therapy, and by their last week of treatment had healed an average of 75%. Forty-one percent of these ulcers healed completely after an average of 11.8 weeks. There were no significant safety problems identified

    Gender differences in the impact of population-level alcohol policy interventions: evidence synthesis of systematic reviews

    Get PDF
    Background: Consistent review-level evidence supports the effectiveness of population-level alcohol policies in reducing alcohol-related harms. Such policies interact with well-established social, cultural and biological differences in how men and women perceive, relate to and use alcohol, and with wider inequalities, in ways which may give rise to gender differences in policy effectiveness.  Aims: To examine the extent to which gender-specific data and analyses were considered in, and are available from, systematic reviews of population-level alcohol policy interventions, and where possible, to conduct a narrative synthesis of relevant data.  Methods: A prior systematic ‘review of reviews’ of population level alcohol interventions 2002-2012 was updated to May 2014, all gender-relevant data extracted, and the level and quality of gender reporting assessed. A narrative synthesis of extracted findings was conducted.  Results: Sixty-three systematic reviews, covering ten policy areas, were included. Five reviews (8%) consistently provided information on baseline participation by gender for each individual study in the review and twenty-nine (46%) reported some gender-specific information on the impact of the policies under consideration. Specific findings include evidence of possible gender differences in the impact of and exposure to alcohol marketing, and a failure to consider potential unintended consequences and harm to others in most reviews.  Conclusions: Gender is poorly reported in systematic reviews of population-level interventions to reduce alcohol-related harm, hindering assessment of the intended and unintended effects of such policies on women and men

    Patient Outcomes with Teaching Versus Nonteaching Healthcare: A Systematic Review

    Get PDF
    BACKGROUND: Extensive debate exists in the healthcare community over whether outcomes of medical care at teaching hospitals and other healthcare units are better or worse than those at the respective nonteaching ones. Thus, our goal was to systematically evaluate the evidence pertaining to this question. METHODS AND FINDINGS: We reviewed all studies that compared teaching versus nonteaching healthcare structures for mortality or any other patient outcome, regardless of health condition. Studies were retrieved from PubMed, contact with experts, and literature cross-referencing. Data were extracted on setting, patients, data sources, author affiliations, definition of compared groups, types of diagnoses considered, adjusting covariates, and estimates of effect for mortality and for each other outcome. Overall, 132 eligible studies were identified, including 93 on mortality and 61 on other eligible outcomes (22 addressed both). Synthesis of the available adjusted estimates on mortality yielded a summary relative risk of 0.96 (95% confidence interval [CI], 0.93–1.00) for teaching versus nonteaching healthcare structures and 1.04 (95% CI, 0.99–1.10) for minor teaching versus nonteaching ones. There was considerable heterogeneity between studies (I(2) = 72% for the main analysis). Results were similar in studies using clinical and those using administrative databases. No differences were seen in the 14 studies fully adjusting for volume/experience, severity, and comorbidity (relative risk 1.01). Smaller studies did not differ in their results from larger studies. Differences were seen for some diagnoses (e.g., significantly better survival for breast cancer and cerebrovascular accidents in teaching hospitals and significantly better survival from cholecystectomy in nonteaching hospitals), but these were small in magnitude. Other outcomes were diverse, but typically teaching healthcare structures did not do better than nonteaching ones. CONCLUSIONS: The available data are limited by their nonrandomized design, but overall they do not suggest that a healthcare facility's teaching status on its own markedly improves or worsens patient outcomes. Differences for specific diseases cannot be excluded, but are likely to be small

    The faint young Sun problem

    Full text link
    For more than four decades, scientists have been trying to find an answer to one of the most fundamental questions in paleoclimatology, the `faint young Sun problem'. For the early Earth, models of stellar evolution predict a solar energy input to the climate system which is about 25% lower than today. This would result in a completely frozen world over the first two billion years in the history of our planet, if all other parameters controlling Earth's climate had been the same. Yet there is ample evidence for the presence of liquid surface water and even life in the Archean (3.8 to 2.5 billion years before present), so some effect (or effects) must have been compensating for the faint young Sun. A wide range of possible solutions have been suggested and explored during the last four decades, with most studies focusing on higher concentrations of atmospheric greenhouse gases like carbon dioxide, methane or ammonia. All of these solutions present considerable difficulties, however, so the faint young Sun problem cannot be regarded as solved. Here I review research on the subject, including the latest suggestions for solutions of the faint young Sun problem and recent geochemical constraints on the composition of Earth's early atmosphere. Furthermore, I will outline the most promising directions for future research. In particular I would argue that both improved geochemical constraints on the state of the Archean climate system and numerical experiments with state-of-the-art climate models are required to finally assess what kept the oceans on the Archean Earth from freezing over completely.Comment: 32 pages, 8 figures. Invited review paper accepted for publication in Reviews of Geophysic

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE
    • …
    corecore