28 research outputs found
The diagnostic ability of SPECT/CT fusion imaging for gastrointestinal bleeding : a retrospective study
Background
Blood loss from the gastrointestinal tract can be an acute and life-threatening event. For the treatment of gastrointestinal bleeding, it is important to accurately detect gastrointestinal bleeding and to localize the sites of bleeding. The purpose of this study was to retrospectively assess the capabilities of SPECT/CT in the diagnosis of gastrointestinal bleeding by a comparison with planar imaging alone as well as planar and SPECT.
Methods
We conducted a retrospective analysis of 20 patients (21 examinations) who underwent gastrointestinal bleeding scintigraphy in the past 7 years and in whom the bleeding site was identified by endoscopy or capsule endoscopy, or in whom no evidence of gastrointestinal bleeding was identified during the clinical course. Five patients (5 examinations) were diagnosed by planar imaging (planar group). Eight patients (9 examinations) were diagnosed by planar imaging and SPECT (planar + SPECT group). Seven patients (7 examinations) were diagnosed by planar imaging and SPECT/CT (planar + SPECT/CT group). We calculated the diagnostic ability of each method in detecting the presence of bleeding, as well as the ability of each method to identify the sites of bleeding. The sensitivity, specificity, and accuracy of the methods were compared.
Results
The diagnostic ability of the three imaging methods in detecting the presence of gastrointestinal bleeding was as follows. Planar imaging showed 100% sensitivity (3/3), 100% specificity (2/2), and 100% accuracy (5/5). Planar + SPECT imaging showed 85.7% sensitivity (6/7), 100% specificity (2/2), and 88.9% accuracy (8/9). Planar + SPECT/CT imaging showed 100% sensitivity (6/6), 100% specificity (1/1), and 100% accuracy (7/7). The diagnostic ability of the three modalities in detecting the site of bleeding was as follows: planar, 33.3% (1/3); planar + SPECT, 71.4% (5/7); and planar + SPECT/CT, 100% (6/6).
Conclusions
All 3 imaging methods showed good accuracy in detecting the presence of gastrointestinal bleeding. The addition of SPECT or SPECT/CT made the anatomical position of the uptake clear and contributed to the localization of the site of gastrointestinal bleeding. Planar + SPECT/CT imaging therefore showed the highest diagnostic ability for detecting the site of gastrointestinal bleeding
Perfusion MRI for brain tumors
Purpose : To compare data on brain tumors derived from intravoxel incoherent motion (IVIM) and arterial spin labeling (ASL) imaging with multiple parameters obtained on dynamic susceptibility contrast (DSC) perfusion MRI and to clarify the characteristics of IVIM and ASL perfusion data from the viewpoint of cerebral blood flow (CBF) analysis. Methods : ASL-CBF and IVIM techniques as well as DSC examination were performed in 24 patients with brain tumors. The IVIM data were analyzed with the two models. The relative blood flow (rBF), relative blood volume (rBV) corrected relative blood volume (crBV), mean transit time (MTT), and leakage coefficient (K2) were obtained from the DSC MRI data. Results : The ASL-CBF had the same tendency as the perfusion parameters derived from the DSC data, but the permeability from the vessels had less of an effect on the ASL-CBF. The diffusion coefficient of the fast component on IVIM contained more information on permeability than the f value. Conclusion : ASL-CBF is more suitable for the evaluation of perfusion in brain tumors than IVIM parameters. ASL-CBF and IVIM techniques should be carefully selected and the biological significance of each parameter should be understood for the correct comprehension of the pathological status of brain tumors
Reproducibility of CBF using pCASL
Purpose : To determine the reproducibility of corrected quantitative cerebral blood flow (qCBF) through measurement of transit flow time using multi-delay three-dimensional pseudo-continuous arterial spin labeling (pCASL) in healthy men and women and to evaluate the differences in qCBF between not only men and women, but also the follicular and luteal phases of the women’s menstrual cycle. Methods : The participants were 16 healthy volunteers (8 men and 8 women ; mean age, 25.3 years). Two MRI were conducted for all participants ; female participants were conducted in the follicular and luteal phases. The reproducibility of qCBF values was evaluated by the intraclass correlation coefficient (ICC) and differences between the two groups were estimated by voxel-based morphometry (VBM) analysis. Results : The qCBF values were lower in men than in women, and those in females were significantly different between the follicular and luteal phases (P < 0.05). In VBM analysis, the qCBF values of the lower frontal lobes were significantly higher in women than in men (P < 0.05). The qCBF values of the frontal pole were significantly higher in the follicular phase than in the luteal phase (P < 0.01). Conclusion : Multi-delay pCASL can reveal physiological and sex differences in cerebral perfusion
Effect of malnutrition on FDG PET
Objective
18F-FDG PET/CT is a hybrid imaging method widely used as a useful, noninvasive imaging modality for evaluating various neoplastic diseases. When assessing the tumor uptake, the liver and the mediastinal blood pool are often used as a reference region. In daily clinical practice, the 18F-FDG uptake in the liver sometimes appears to decrease on PET images of patients with malnutrition. The purpose of this study was to investigate whether or not the liver 18F-FDG uptake is decreased in patients with malnutrition.
Methods
We retrospectively analyzed 246 patients who underwent 18F-FDG PET/CT from January 2018 to June 2018 and whose blood serum albumin was measured within 1 month of PET/CT. We compared the liver uptake and mediastinal blood uptake of patients with low serum albumin level (< 4.0 g/dl) and hypoalbuminemia (< 3.5 g/dl) with those with a normal serum albumin level (≥ 4.0 g/dl). Correlations between the liver and mediastinal blood uptake and the serum albumin level were also calculated.
Results
The maximum standardized uptake value (SUVmax) and mean standardized uptake value (SUVmean) of the liver in 117 patients with low serum albumin were 3.1 ± 0.5 and 2.3 ± 0.3, respectively, while they were 2.9 ± 0.4, 2.0 ± 0.3 in 29 patients with hypoalbuminemia; these values were all significantly lower than the respective ones (3.4 ± 0.5, 2.5 ± 0.4) in 129 patients with normal serum albumin (all p < 0.001). The SUVmean of the mediastinal blood uptake in patients with hypoalbuminemia and normal serum albumin were 1.6 ± 0.2 and 1.7 ± 0.3, respectively (p = 0.053). The serum albumin level demonstrated a significantly positive, moderate correlation with the liver SUVmean, showing a regression line of y = 0.31x + 1.1 (r = 0.41, p < 0.001).
Conclusion
The liver 18F-FDG uptake tended to decrease in patients with hypoalbuminemia. In the patients with malnutrition, the mediastinal blood pool may be more stable reference than the liver for evaluating the tumor activity because hypoalbuminemia is considered to less strongly influence the mediastinal blood pool than that in the liver
T1rho and T2 relaxation times of the normal adult knee meniscus at 3T : analysis of zonal differences
Background: Prior studies describe histological and immunohistochemical differences in collagen and proteoglycan content in different meniscal zones. The aim of this study is to evaluate horizontal and vertical zonal differentiation of T1rho and T2 relaxation times of the entire meniscus from volunteers without symptom and imaging abnormality.
Methods: Twenty volunteers age between 19 and 38 who have no knee-related clinical symptoms, and no history of prior knee surgeries were enrolled in this study. Two T1rho mapping (b-FFE T1rho and SPGR T1rho) and T2 mapping images were acquired with a 3.0-T MR scanner. Each meniscus was divided manually into superficial and deep zones for horizontal zonal analysis. The anterior and posterior horns of each meniscus were divided manually into white, red-white and red zones for vertical zonal analysis. Zonal differences of average relaxation times among each zone, and both inter- and intra-observer reproducibility were statistically analyzed.
Results: In horizontal zonal analysis, T1rho relaxation times of the superficial zone tended to be higher than those of the deep zone, and this difference was statistically significant in the medial meniscal segments (84.3 ms vs 76.0 ms on b-FFE, p 0.74) or good (0.60–0.74) in all meniscal segments on both horizontal and vertical zonal analysis, except for inter-class correlation coefficients of the lateral meniscus on SPGR. Compared with SPGR T1rho images, b-FFE T1rho images demonstrated more significant zonal differentiation with higher inter- and intra-observer reproducibility.
Conclusions: There are zonal differences in T1rho and T2 relaxation times of the normal meniscus
T1rho and T2 relaxation times of the normal adult knee meniscus at 3T : analysis of zonal differences
Background: Prior studies describe histological and immunohistochemical differences in collagen and proteoglycan content in different meniscal zones. The aim of this study is to evaluate horizontal and vertical zonal differentiation of T1rho and T2 relaxation times of the entire meniscus from volunteers without symptom and imaging abnormality.
Methods: Twenty volunteers age between 19 and 38 who have no knee-related clinical symptoms, and no history of prior knee surgeries were enrolled in this study. Two T1rho mapping (b-FFE T1rho and SPGR T1rho) and T2 mapping images were acquired with a 3.0-T MR scanner. Each meniscus was divided manually into superficial and deep zones for horizontal zonal analysis. The anterior and posterior horns of each meniscus were divided manually into white, red-white and red zones for vertical zonal analysis. Zonal differences of average relaxation times among each zone, and both inter- and intra-observer reproducibility were statistically analyzed.
Results: In horizontal zonal analysis, T1rho relaxation times of the superficial zone tended to be higher than those of the deep zone, and this difference was statistically significant in the medial meniscal segments (84.3 ms vs 76.0 ms on b-FFE, p 0.74) or good (0.60–0.74) in all meniscal segments on both horizontal and vertical zonal analysis, except for inter-class correlation coefficients of the lateral meniscus on SPGR. Compared with SPGR T1rho images, b-FFE T1rho images demonstrated more significant zonal differentiation with higher inter- and intra-observer reproducibility.
Conclusions: There are zonal differences in T1rho and T2 relaxation times of the normal meniscus
統合失調症におけるSalience Network機能障害、抑うつ気分、および主観的QOLの因果関係を評価する構造方程式モデリングアプローチ : 独立成分分析による安静時fMRI研究
Purpose: Quality of life (QOL) is an important clinical outcome for patients with schizophrenia, and recent studies have focused on subjective QOL. We evaluated the causal relationship between psychosocial aspect of subjective QOL, symptoms, cognitive functions, and salience network (SN) dysfunction in schizophrenia using structural equation modeling (SEM).
Patients and methods: We performed a cross-sectional study of 21 patients with symptomatically stabilized schizophrenia and 21 age-, sex-, and education level-matched healthy controls who underwent resting-state functional magnetic resonance imaging. We evaluated SN dysfunction in schizophrenia using independent component analysis (ICA). We rated participant psychopathology using the Positive and Negative Syndrome Scale (PANSS), the Brief Assessment of Cognition in Schizophrenia (BACS), and the Calgary Depression Scale for Schizophrenia (CDSS). We rated psychosocial aspect of subjective QOL using the Schizophrenia Quality of Life Scale (SQLS) psychosocial subscale. We applied SEM to examine the relationships between SN dysfunction, PANSS positive and negative scores, CDSS total scores, BACS composite scores, and SQLS psychosocial subscale scores.
Results: In second-level analysis after group ICA, patient group had significant lower right pallidum functional connectivity (FC) within the SN than the controls did (Montreal Neurological Institute [MNI] [x y z] = [22 -2 -6]) (p = 0.027, family-wise error [FWE] corrected). In SEM, we obtained a good fit for an SEM model in which SN dysfunction causes depressed mood, which in turn determines psychosocial aspect of subjective QOL (chi-squared p = 0.9, root mean square error of approximation (RMSEA) < 0.001, comparative fit index [CFI] = 1.00, and standardized root mean square residual [SRMR]= 0.020).
Conclusion: We found a continuous process by which SN dysfunction causes depressed moods that determine psychosocial aspect of subjective QOL in schizophrenia. This is the first report that offers a unified explanation of functional neuroimaging, symptoms, and outcomes. Future studies combining neuroimaging techniques and clinical assessments would elucidate schizophrenia’s pathogenesis
Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)
In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. For example, a key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process versus those that measure fl ux through the autophagy pathway (i.e., the complete process including the amount and rate of cargo sequestered and degraded). In particular, a block in macroautophagy that results in autophagosome accumulation must be differentiated from stimuli that increase autophagic activity, defi ned as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (inmost higher eukaryotes and some protists such as Dictyostelium ) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the fi eld understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. It is worth emphasizing here that lysosomal digestion is a stage of autophagy and evaluating its competence is a crucial part of the evaluation of autophagic flux, or complete autophagy. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. Along these lines, because of the potential for pleiotropic effects due to blocking autophagy through genetic manipulation it is imperative to delete or knock down more than one autophagy-related gene. In addition, some individual Atg proteins, or groups of proteins, are involved in other cellular pathways so not all Atg proteins can be used as a specific marker for an autophagic process. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field
The diagnostic ability of SPECT/CT fusion imaging for gastrointestinal bleeding: a retrospective study
Abstract Background Blood loss from the gastrointestinal tract can be an acute and life-threatening event. For the treatment of gastrointestinal bleeding, it is important to accurately detect gastrointestinal bleeding and to localize the sites of bleeding. The purpose of this study was to retrospectively assess the capabilities of SPECT/CT in the diagnosis of gastrointestinal bleeding by a comparison with planar imaging alone as well as planar and SPECT. Methods We conducted a retrospective analysis of 20 patients (21 examinations) who underwent gastrointestinal bleeding scintigraphy in the past 7 years and in whom the bleeding site was identified by endoscopy or capsule endoscopy, or in whom no evidence of gastrointestinal bleeding was identified during the clinical course. Five patients (5 examinations) were diagnosed by planar imaging (planar group). Eight patients (9 examinations) were diagnosed by planar imaging and SPECT (planar + SPECT group). Seven patients (7 examinations) were diagnosed by planar imaging and SPECT/CT (planar + SPECT/CT group). We calculated the diagnostic ability of each method in detecting the presence of bleeding, as well as the ability of each method to identify the sites of bleeding. The sensitivity, specificity, and accuracy of the methods were compared. Results The diagnostic ability of the three imaging methods in detecting the presence of gastrointestinal bleeding was as follows. Planar imaging showed 100% sensitivity (3/3), 100% specificity (2/2), and 100% accuracy (5/5). Planar + SPECT imaging showed 85.7% sensitivity (6/7), 100% specificity (2/2), and 88.9% accuracy (8/9). Planar + SPECT/CT imaging showed 100% sensitivity (6/6), 100% specificity (1/1), and 100% accuracy (7/7). The diagnostic ability of the three modalities in detecting the site of bleeding was as follows: planar, 33.3% (1/3); planar + SPECT, 71.4% (5/7); and planar + SPECT/CT, 100% (6/6). Conclusions All 3 imaging methods showed good accuracy in detecting the presence of gastrointestinal bleeding. The addition of SPECT or SPECT/CT made the anatomical position of the uptake clear and contributed to the localization of the site of gastrointestinal bleeding. Planar + SPECT/CT imaging therefore showed the highest diagnostic ability for detecting the site of gastrointestinal bleeding