70 research outputs found

    Efficiency of true-green light emitting diodes:Non-uniformity and temperature effects

    Get PDF
    External quantum efficiency of industrial-grade green InGaN light-emitting diodes (LEDs) has been measured in a wide range of operating currents at various temperatures from 13 K to 300 K. Unlike blue LEDs, the efficiency as a function of current is found to have a multi-peak character, which could not be fitted by a simple ABC-model. This observation correlated with splitting of LED emission spectra into two peaks at certain currents. The characterization data are interpreted in terms of non-uniformity of the LED active region, which is tentatively attributed to extended defects like V-pits. We suggest a new approach to evaluation of temperature-dependent light extraction and internal quantum efficiencies taking into account the active region non-uniformity. As a result, the temperature dependence of light extraction and internal quantum efficiencies have been evaluated in the temperature range mentioned above and compared with those of blue LEDs

    Relationships between self-reported childhood traumatic experiences, attachment style, neuroticism and features of borderline personality disorders in patients with mood disorders

    Get PDF
    Background: Co-occurring borderline personality disorder (BPD) features have a marked impact on treatment of patients with mood disorders. Overall, high neuroticism, childhood traumatic experiences (TEs) and insecure attachment are plausible aetiological factors for BPD. However, their relationship with BPD features specifically among patients with mood disorders remains unclear. We investigated these relationships among unipolar and bipolar mood disorder patients. Methods: As part of the Helsinki University Psychiatric Consortium study, the McLean Screening Instrument (MSI), the Experiences in Close Relationships-Revised (ECR-R), the Short Five (S5) and the Trauma and Distress Scale (TADS) were filled in by patients with mood disorders (n=282) in psychiatric care. Correlation coefficients between total scores of scales and their dimensions were estimated, and multivariate regression (MRA) and mediation analyses were conducted. Results: Spearman's correlations were strong (rho=0.58; p <0.001) between total scores of MSI and S5 Neuroticism and moderate (rho=0.42; p <0.001) between MSI and TADS as well as between MSI and ECR-R Attachment Anxiety. In MRA, young age, S5 Neuroticism and TADS predicted scores of MSI (p <0.001). ECR-R Attachment Anxiety mediated 33% (CI=17-53%) of the relationships between TADS and MSI. Limitations: Cross-sectional questionnaire study. Conclusions: We found moderately strong correlations between self-reported BPD features and concurrent high neuroticism, reported childhood traumatic experiences and Attachment Anxiety also among patients with mood disorders. Independent predictors for BPD features include young age, frequency of childhood traumatic experiences and high neuroticism. Insecure attachment may partially mediate the relationship between childhood traumatic experiences and borderline features among mood disorder patients.Peer reviewe

    Differences and similarities of risk factors for suicidal ideation and attempts among patients with depressive or bipolar disorders

    Get PDF
    Background: Substantial literature exists on risk factors for suicidal behaviour. However, their comparative strength, independence and specificity for either suicidal ideation or suicide attempt(s) remain unclear. Methods: The Helsinki University Psychiatric Consortium (HUPC) Study surveyed 287 psychiatric care patients with ICD-10-DCR depressive or bipolar disorders about lifetime suicidal behaviour, developmental history and attachment style, personality and psychological traits, current and lifetime symptom profiles, and life events. Psychiatric records were used to confirm diagnosis and complement information on suicide attempts. Multinomial regression models predicting lifetime suicidal ideation and single or repeated suicide attempts were generated. Results: Overall, 21.6% patients had no lifetime suicidal behaviour, 33.8% had lifetime suicide ideation without attempts, and 17.1% had a single and 27.5% repeated suicide attempts. In univariate analyses, lifetime suicidal behaviour was associated with numerous factors. In multivariate models, suicidal ideation was independently predicted by younger age, severe depressive disorder, bipolar disorder type II/nos, hopelessness, and childhood physical abuse. Repeated suicide attempts were independently predicted by younger age, female sex, severe depressive disorder with or without psychotic symptoms, bipolar disorder type II/nos, alcohol use disorder, borderline personality disorder traits, and childhood physical abuse. Limitations: Cross-sectional and retrospective study design, utilization of clinical diagnoses, and relatively low response rate. Conclusions: Risk factors for suicidal ideation and attempts may diverge both qualitatively and in terms of dose response. When effects of risk factors from multiple domains are concurrently examined, proximal clinical characteristics remain the most robust. All risk factors cluster into the group of repeated attempters. (C) 2015 Elsevier B.V. All rights reserved.Peer reviewe

    Temperature-dependent internal quantum efficiency of blue high-brightness light-emitting diodes

    Get PDF
    Internal quantum efficiency (IQE) of a blue high-brightness InGaN/GaN light-emitting diode (LED) was evaluated from the external quantum efficiency measured as a function of current at various temperatures ranged between 13 and 440 K. Processing the data with a novel evaluation procedure based on the ABC-model, we have determined the temperature-dependent IQE of the LED structure and light extraction efficiency of the LED chip. Separate evaluation of these parameters is helpful for further optimization of the heterostructure and chip designs. The data obtained enable making a guess on the temperature dependence of the radiative and Auger recombination coefficients, which may be important for identification of dominant mechanisms responsible for the efficiency droop in III-nitride LEDs. Thermal degradation of the LED performance in terms of the emission efficiency is also considered

    AlGaInP red-emitting light emitting diode under extremely high pulsed pumping

    Get PDF
    Efficiency of commercial 620 nm InAlGaP Golden Dragon-cased high-power LEDs has been studied under extremely high pump current density up to 4.5 kA/cm2 and pulse duration from microsecond down to sub-nanosecond range. No efficiency decrease and negligible red shift of the emission wavelength is observed in the whole range of drive currents at nanosecond-range pulses with duty cycles well below 1%. Analysis of the pulse-duration dependence of the LED efficiency and emission spectrum suggests the active region overheating to be the major mechanism of the LED efficiency reduction at higher pumping, dominating over the electron overflow and Auger recombination

    Temperature effects on optical properties and efficiency of red AlGaInP-based light emitting diodes under high current pulse pumping

    Get PDF
    In this paper, current-dependent emission spectra and efficiency measured on the same AlGaInP red light-emitting diode (LED) pumped with the current pulses of very different durations are recorded. This enabled for the first time distinguishing between high-carrier concentration and self-heating effects on the efficiency decline at high current magnitudes. The electron leakage to the p-side of the LED structure, which is the major mechanism of the efficiency reduction, is found to rise substantially when the device self-heating starts to develop. As a result, in comparison to continuous-wave excitation, driving the LED with sub-microsecond current pulses allows suppressing the device self-heating and, eventually, increasing the operating current by an order of magnitude without noticeable efficiency losses. Based on the reduced ABC-model, neglecting Auger recombination, the light extraction efficiency, injection efficiency, and internal quantum efficiency of the LED are estimated, suggesting light extraction to be the most critical factor for the overall efficiency of the LED. The coupled spectral/power LED characterization using the variable-duration current pulse pumping is found to be an effective approach for analyzing mechanisms of the device operation

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Combinations of single-top-quark production cross-section measurements and vertical bar f(LV)V(tb)vertical bar determinations at root s=7 and 8 TeV with the ATLAS and CMS experiments

    Get PDF
    This paper presents the combinations of single-top-quark production cross-section measurements by the ATLAS and CMS Collaborations, using data from LHC proton-proton collisions at = 7 and 8 TeV corresponding to integrated luminosities of 1.17 to 5.1 fb(-1) at = 7 TeV and 12.2 to 20.3 fb(-1) at = 8 TeV. These combinations are performed per centre-of-mass energy and for each production mode: t-channel, tW, and s-channel. The combined t-channel cross-sections are 67.5 +/- 5.7 pb and 87.7 +/- 5.8 pb at = 7 and 8 TeV respectively. The combined tW cross-sections are 16.3 +/- 4.1 pb and 23.1 +/- 3.6 pb at = 7 and 8 TeV respectively. For the s-channel cross-section, the combination yields 4.9 +/- 1.4 pb at = 8 TeV. The square of the magnitude of the CKM matrix element V-tb multiplied by a form factor f(LV) is determined for each production mode and centre-of-mass energy, using the ratio of the measured cross-section to its theoretical prediction. It is assumed that the top-quark-related CKM matrix elements obey the relation |V-td|, |V-ts| << |V-tb|. All the |f(LV)V(tb)|(2) determinations, extracted from individual ratios at = 7 and 8 TeV, are combined, resulting in |f(LV)V(tb)| = 1.02 +/- 0.04 (meas.) +/- 0.02 (theo.). All combined measurements are consistent with their corresponding Standard Model predictions.Peer reviewe
    corecore