297 research outputs found

    Socially-marketed rapid diagnostic tests and ACT in the private sector: ten years of experience in Cambodia.

    Get PDF
    Whilst some populations have recently experienced dramatic declines in malaria, the majority of those most at risk of Plasmodium falciparum malaria still lack access to effective treatment with artemisinin combination therapy (ACT) and others are already facing parasites resistant to artemisinins.In this context, there is a crucial need to improve both access to and targeting of ACT through greater availability of good quality ACT and parasitological diagnosis. This is an issue of increasing urgency notably in the private commercial sector, which, in many countries, plays an important role in the provision of malaria treatment. The Affordable Medicines Facility for malaria (AMFm) is a recent initiative that aims to increase the provision of affordable ACT in public, private and NGO sectors through a manufacturer-level subsidy. However, to date, there is little documented experience in the programmatic implementation of subsidized ACT in the private sector. Cambodia is in the unique position of having more than 10 years of experience not only in implementing subsidized ACT, but also rapid diagnostic tests (RDT) as part of a nationwide social marketing programme. The programme includes behaviour change communication and the training of private providers as well as the sale and distribution of Malarine, the recommended ACT, and Malacheck, the RDT. This paper describes and evaluates this experience by drawing on the results of household and provider surveys conducted since the start of the programme. The available evidence suggests that providers' and consumers' awareness of Malarine increased rapidly, but that of Malacheck much less so. In addition, improvements in ACT and RDT availability and uptake were relatively slow, particularly in more remote areas.The lack of standardization in the survey methods and the gaps in the data highlight the importance of establishing a clear system for monitoring and evaluation for similar initiatives. Despite these limitations, a number of important lessons can still be learnt. These include the importance of a comprehensive communications strategy and of a sustained and reliable supply of products, with attention to the geographical reach of both. Other important challenges relate to the difficulty in incentivising providers and consumers not only to choose the recommended drug, but to precede this with a confirmatory blood test and ensure that providers adhere to the test results and patients to the treatment regime. In Cambodia, this is particularly complicated due to problems inherent to the drug itself and the emergence of artemisinin resistance

    Refractive ocular conditions and reasons for spectacles renewal in a resource-limited economy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although a leading cause of visual impairment and a treatable cause of blindness globally, the pattern of refractive errors in many populations is unknown. This study determined the pattern of refractive ocular conditions, reasons for spectacles renewal and the effect of correction on refractive errors in a resource-limited community.</p> <p>Methods</p> <p>A retrospective review of case records of 1,413 consecutive patients seen in a private optometry practice, Nigeria between January 2006 and July 2007.</p> <p>Results</p> <p>A total number of 1,216 (86.1%) patients comprising of (486, 40%) males and (730, 60%) females with a mean age of 41.02 years SD 14.19 were analyzed. The age distribution peaked at peri-adolescent and the middle age years. The main ocular complaints were spectacles loss and discomfort (412, 33.9%), blurred near vision (399, 32.8%) and asthenopia (255, 20.9%). The mean duration of ocular symptoms before consultation was 2.05 years SD 1.92. The most common refractive errors include presbyopia (431, 35.3%), hyperopic astigmatism (240, 19.7%) and presbyopia with hyperopia (276, 22.7%). Only (59, 4.9%) had myopia. Following correction, there were reductions in magnitudes of the blind (VA<3/60) and visually impaired (VA<6/18-3/60) patients by (18, 58.1%) and (89, 81.7%) respectively. The main reasons for renewal of spectacles were broken lenses/frame/scratched lenses/lenses' falling off (47, 63.4%).</p> <p>Conclusions</p> <p>Adequate correction of refractive errors reduces visual impairment and avoidable blindness and to achieve optimal control of refractive errors in the community, services should be targeted at individuals in the peri-adolescent and the middle age years.</p

    Optical Coherence Tomography in the UK Biobank Study – Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies

    Get PDF
    Purpose: To describe an approach to the use of optical coherence tomography (OCT) imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness. Methods: In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available “spectral domain” OCT device (3D OCT-1000, Topcon). Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL). This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion. Results: 67,321 participants (134,642 eyes) in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days. Conclusions: We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging

    Cohort profile: design and methods in the eye and vision consortium of UK Biobank

    Get PDF
    PURPOSE: To describe the rationale, methods and research potential of eye and vision measures available in UK Biobank. PARTICIPANTS: UK Biobank is a large, multisite, prospective cohort study. Extensive lifestyle and health questionnaires, a range of physical measures and collection of biological specimens are collected. The scope of UK Biobank was extended midway through data collection to include assessments of other measures of health, including eyes and vision. The eye assessment at baseline included questionnaires detailing past ophthalmic and family history, measurement of visual acuity, refractive error and keratometry, intraocular pressure (IOP), corneal biomechanics, spectral domain optical coherence tomography (OCT) of the macula and a disc-macula fundus photograph. Since recruitment, UK Biobank has collected accelerometer data and begun multimodal imaging data (including brain, heart and abdominal MRI) in 100 000 participants. Dense genotypic data and a panel of 20 biochemistry measures are available, and linkage to medical health records for the full cohort has begun. FINDINGS TO DATE: A total of 502 665 people aged between 40 and 69 were recruited to participate in UK Biobank. Of these, 117 175 took part in baseline assessment of vision, IOP, refraction and keratometry. A subgroup of 67 321 underwent OCT and retinal photography. The introduction of eye and vision measures in UK Biobank was accompanied by intensive training, support and a data monitoring quality control process. FUTURE PLANS: UK Biobank is one of the largest prospective cohorts worldwide with extensive data on ophthalmic diseases and conditions. Data collection is an ongoing process and a repeat of the baseline assessment including the questionnaires, measurements and sample collection will be performed in subsets of 25 000 participants every 2-3 years. The depth and breadth of this dataset, coupled with its open-access policy, will create a powerful resource for all researchers to investigate the eye diseases in later life

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Periodontitis and Outer Retinal Thickness: a Cross-Sectional Analysis of the United Kingdom Biobank Cohort

    Get PDF
    \ua9 2024 American Academy of OphthalmologyPurpose: Periodontitis, a ubiquitous severe gum disease affecting the teeth and surrounding alveolar bone, can heighten systemic inflammation. We investigated the association between very severe periodontitis and early biomarkers of age-related macular degeneration (AMD), in individuals with no eye disease. Design: Cross-sectional analysis of the prospective community-based cohort United Kingdom (UK) Biobank. Participants: Sixty-seven thousand three hundred eleven UK residents aged 40 to 70 years recruited between 2006 and 2010 underwent retinal imaging. Methods: Macular-centered OCT images acquired at the baseline visit were segmented for retinal sublayer thicknesses. Very severe periodontitis was ascertained through a touchscreen questionnaire. Linear mixed effects regression modeled the association between very severe periodontitis and retinal sublayer thicknesses, adjusting for age, sex, ethnicity, socioeconomic status, alcohol consumption, smoking status, diabetes mellitus, hypertension, refractive error, and previous cataract surgery. Main Outcome Measures: Photoreceptor layer (PRL) and retinal pigment epithelium–Bruch\u27s membrane (RPE–BM) thicknesses. Results: Among 36 897 participants included in the analysis, 1571 (4.3%) reported very severe periodontitis. Affected individuals were older, lived in areas of greater socioeconomic deprivation, and were more likely to be hypertensive, diabetic, and current smokers (all P &lt; 0.001). On average, those with very severe periodontitis were hyperopic (0.05 \ub1 2.27 diopters) while those unaffected were myopic (−0.29 \ub1 2.40 diopters, P &lt; 0.001). Following adjusted analysis, very severe periodontitis was associated with thinner PRL (−0.55 μm, 95% confidence interval [CI], −0.97 to −0.12; P = 0.022) but there was no difference in RPE–BM thickness (0.00 μm, 95% CI, −0.12 to 0.13; P = 0.97). The association between PRL thickness and very severe periodontitis was modified by age (P &lt; 0.001). Stratifying individuals by age, thinner PRL was seen among those aged 60 to 69 years with disease (−1.19 μm, 95% CI, −1.85 to −0.53; P &lt; 0.001) but not among those aged &lt; 60 years. Conclusions: Among those with no known eye disease, very severe periodontitis is statistically associated with a thinner PRL, consistent with incipient AMD. Optimizing oral hygiene may hold additional relevance for people at risk of degenerative retinal disease. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article

    Measurement of the W±Z boson pair-production cross section in pp collisions at √s=13TeV with the ATLAS detector

    Get PDF
    published_or_final_versio

    Search for High-Mass Resonances Decaying to τν in pp Collisions at √s=13 TeV with the ATLAS Detector

    Get PDF
    A search for high-mass resonances decaying to τν using proton-proton collisions at √s=13 TeV produced by the Large Hadron Collider is presented. Only τ-lepton decays with hadrons in the final state are considered. The data were recorded with the ATLAS detector and correspond to an integrated luminosity of 36.1 fb−1. No statistically significant excess above the standard model expectation is observed; model-independent upper limits are set on the visible τν production cross section. Heavy W′ bosons with masses less than 3.7 TeV in the sequential standard model and masses less than 2.2–3.8 TeV depending on the coupling in the nonuniversal G(221) model are excluded at the 95% credibility level

    Search for the direct production of charginos and neutralinos in final states with tau leptons in √s=13 TeV collisions with the ATLAS detector

    Get PDF
    A search for the direct production of charginos and neutralinos in final states with at least two hadronically decaying tau leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 36.1 fb−1, recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13TeV.Nosignificant deviation from the expected Standard Model background is observed. Limits are derived in scenarios of ˜χ+1 ˜χ−1 pair production and of ˜χ±1 ˜χ02 and ˜χ+1 ˜χ−1 production in simplified models where the neutralinos and charginos decay solely via intermediate left-handed staus and tau sneutrinos, and the mass of the ˜ τL state is set to be halfway between the masses of the ˜χ±1 and the ˜χ01. Chargino masses up to 630 GeV are excluded at 95% confidence level in the scenario of direct production of ˜χ+1 ˜χ−1 for a massless ˜χ01. Common ˜χ±1 and ˜χ02 masses up to 760 GeV are excluded in the case of production of ˜χ±1 ˜χ02 and ˜χ+1 ˜χ−1 assuming a massless ˜χ01. Exclusion limits for additional benchmark scenarios with large and small mass-splitting between the ˜χ±1 and the ˜χ01 are also studied by varying the ˜ τL mass between the masses of the ˜χ±1 and the ˜χ01
    corecore