93 research outputs found
Liquid recirculation in microfluidic channels by the interplay of capillary and centrifugal forces
We demonstrate a technique to recirculate liquids in a microfluidic device, maintaining a thin fluid layer such that typical diffusion times for analytes to reach the device surface are < 1 min. Fluids can be recirculated at least 1000 times across the same surface region, with no change other than slight evaporation, by alternating the predominance of centrifugal and capillary forces. Mounted on a rotational platform, the device consists of two hydrophilic layers separated by a thin pressure-sensitive adhesive (PSA) layer that defines the microfluidic structure. We demonstrate rapid, effective fluid mixing with this device
Protein pattern transfer for biosensor applications
This paper presents a very simple, industrially scalable method for transferring a high-resolution, biologically active protein pattern from one substrate to another. We demonstrate the transfer of a protein pattern formed initially by microcontact printing from a silicon surface (to which this form of printing is applicable) onto a glass or polymer substrate, almost independently of the surface/bulk properties of the second substrate. A very thin, spin-coated layer of a sugar is used to preserve the structure and organization of proteins during the subsequent plasma deposition of a siloxane polymer, after which the protein pattern could simply be peeled off the silicon substrate and glued onto any other desired substrate. Ă© 2009 Elsevier B.V. All rights reserved
Type 1 Diabetes Mellitus reversal via implantation of magnetically purified microencapsulated pseudoislets
[Abstract] Microencapsulation of pancreatic islets for the treatment of Type I Diabetes Mellitus (T1DM) generates a high quantity of empty microcapsules, resulting in high therapeutic graft volumes that can enhance the hostâs immune response. We report a 3D printed microfluidic magnetic sorting device for microcapsules purification with the objective to reduce the number of empty microcapsules prior transplantation. In this study, INS1E pseudoislets were microencapsulated within alginate (A) and alginate-poly-L-lysine-alginate (APA) microcapsules and purified through the microfluidic device. APA microcapsules demonstrated higher mechanical integrity and stability than A microcapsules, showing better pseudoislets viability and biological function. Importantly, we obtained a reduction of the graft volume of 77.5% for A microcapsules and 78.6% for APA microcapsules. After subcutaneous implantation of induced diabetic Wistar rats with magnetically purified APA microencapsulated pseudoislets, blood glucose levels were restored into normoglycemia (<200âŻmg/dL) for almost 17 weeks. In conclusion, our described microfluidic magnetic sorting device represents a great alternative approach for the graft volume reduction of microencapsulated pseudoislets and its application in T1DM disease.Universidad del PaĂs Vasco; ESPPOC 16/65Universidad del PaĂs vasco; EHUa16/06Gobierno Vasco; IT907-16Gobierno Vasco; KK-2017/0000088Gobierno Vasco; 307616FKA4Ministerio de EconomĂa y Competitividad; RYC-2012-1079
Self-assembled hydrogel fibers for sensing the multi-compartment intracellular milieu
Targeted delivery of drugs and sensors into cells is an attractive technology with both medical and scientific applications. Existing delivery vehicles are generally limited by the complexity of their design, dependence on active transport, and inability to function within cellular compartments. Here, we developed self-assembled nanofibrous hydrogel fibers using a biologically inert, low-molecular-weight amphiphile. Self-assembled nanofibrous hydrogels offer unique physical/mechanical properties and can easily be loaded with a diverse range of payloads. Unlike commercially available E. coli membrane particles covalently bound to the pH reporting dye pHrodo, pHrodo encapsulated in self-assembled hydrogel-fibers internalizes into macrophages at both physiologic (37°C) and sub-physiologic (4°C) temperatures through an energy-independent, passive process. Unlike dye alone or pHrodo complexed to E. coli, pHrodo-SAFs report pH in both the cytoplasm and phagosomes, as well the nucleus. This new class of materials should be useful for next-generation sensing of the intracellular milieu
Combinatorial Fabrication of Fluorescent Patterns with Metal Ions Using Soft Lithography
A new combinatorial methodology for the fabrication and direct visualization of fluorescent and metal-ion micrometer patterns is presented. Microcontact printing is used to transfer different metal salts onto a variety of fluorescent monolayers on glass
Fabrication and visualization of metal-ion patterns on glass by dip-pen nanolithography
Fluorescent self-assembled monolayers (SAMs) are used as dip-pen nanolithography (DPN) substrates for the fabrication of patterns of Ca(2+) and Cu(2+) ions. The driving force for the transfer of these ions from an atomic force microscopy (AFM) tip to the surface is their complexation to organic ligands on the monolayer. By means of fluorescent surfaces, the patterns can be visualized under a fluorescence microscope. We use a custom-built atomic force fluorescence microscope (AFFM), a combination of atomic force and confocal fluorescence microscopes, to deposit the metal ions onto the sensing SAMs by DPN and to subsequently visualize modulations of fluorescence intensity in a sequential write-read mode